| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128 |
- """Tests for the Quto 03 Sprinkler."""
- from homeassistant.components.binary_sensor import BinarySensorDeviceClass
- from homeassistant.components.number import NumberDeviceClass
- from homeassistant.components.valve import ValveDeviceClass, ValveEntityFeature
- from homeassistant.const import PERCENTAGE, UnitOfTime
- from ..const import QOTO_SPRINKLER_PAYLOAD
- from ..helpers import assert_device_properties_set
- from ..mixins.binary_sensor import BasicBinarySensorTests
- from ..mixins.number import MultiNumberTests
- from ..mixins.sensor import MultiSensorTests
- from .base_device_tests import TuyaDeviceTestCase
- TARGET_DPS = "102"
- CURRENT_DPS = "103"
- COUNTDOWN_DPS = "104"
- TIMER_DPS = "105"
- ERROR_DPS = "108"
- class TestQotoSprinkler(
- BasicBinarySensorTests,
- MultiNumberTests,
- MultiSensorTests,
- TuyaDeviceTestCase,
- ):
- __test__ = True
- def setUp(self):
- self.setUpForConfig("qoto_03_sprinkler.yaml", QOTO_SPRINKLER_PAYLOAD)
- self.subject = self.entities.get("valve_water")
- self.setUpBasicBinarySensor(
- ERROR_DPS,
- self.entities.get("binary_sensor_problem"),
- device_class=BinarySensorDeviceClass.PROBLEM,
- testdata=(1, 0),
- )
- self.setUpMultiNumber(
- [
- {
- "name": "number_timer",
- "dps": TIMER_DPS,
- "max": 86399,
- "device_class": NumberDeviceClass.DURATION,
- "unit": UnitOfTime.SECONDS,
- },
- ]
- )
- self.setUpMultiSensors(
- [
- {
- "name": "sensor_open",
- "dps": CURRENT_DPS,
- "unit": "%",
- },
- {
- "name": "sensor_time_remaining",
- "dps": COUNTDOWN_DPS,
- "device_class": "duration",
- "unit": "s",
- },
- ]
- )
- self.mark_secondary(
- [
- "number",
- "binary_sensor_problem",
- "number_timer",
- "sensor_open",
- "sensor_time_remaining",
- ]
- )
- def test_device_class_is_water(self):
- self.assertEqual(self.subject.device_class, ValveDeviceClass.WATER)
- def test_supported_features(self):
- self.assertEqual(
- self.subject.supported_features,
- ValveEntityFeature.OPEN
- | ValveEntityFeature.CLOSE
- | ValveEntityFeature.SET_POSITION,
- )
- def test_is_closed(self):
- self.dps[TARGET_DPS] = 100
- self.assertFalse(self.subject.is_closed)
- self.dps[TARGET_DPS] = 50
- self.assertFalse(self.subject.is_closed)
- self.dps[TARGET_DPS] = 0
- self.assertTrue(self.subject.is_closed)
- def test_current_position(self):
- self.dps[TARGET_DPS] = 100
- self.assertEqual(self.subject.current_position, 100)
- self.dps[TARGET_DPS] = 50
- self.assertEqual(self.subject.current_position, 50)
- self.dps[TARGET_DPS] = 0
- self.assertEqual(self.subject.current_position, 0)
- async def test_open_valve(self):
- async with assert_device_properties_set(
- self.subject._device,
- {TARGET_DPS: 100},
- ):
- await self.subject.async_open_valve()
- async def test_close_valve(self):
- async with assert_device_properties_set(
- self.subject._device,
- {TARGET_DPS: 0},
- ):
- await self.subject.async_close_valve()
- async def test_set_valve_position(self):
- async with assert_device_properties_set(
- self.subject._device,
- {TARGET_DPS: 50},
- ):
- await self.subject.async_set_valve_position(50)
- def test_basic_bsensor_extra_state_attributes(self):
- self.dps[ERROR_DPS] = 2
- self.assertDictEqual(
- self.basicBSensor.extra_state_attributes,
- {"fault_code": 2},
- )
|