Просмотр исходного кода

fix (vt_14n1_airquality): use correct scale for H2CO and TVOC

Was off by one decimal place due to misreading of mg on screen vs more
natural μg reported by device.
Jason Rumney 10 месяцев назад
Родитель
Сommit
ce3c784ec2
1 измененных файлов с 0 добавлено и 4 удалено
  1. 0 4
      custom_components/tuya_local/devices/vt_14n1_airquality.yaml

+ 0 - 4
custom_components/tuya_local/devices/vt_14n1_airquality.yaml

@@ -59,8 +59,6 @@ entities:
         name: sensor
         unit: ugm3
         class: measurement
-        mapping:
-          - scale: 0.1
   - entity: sensor
     class: volatile_organic_compounds
     dps:
@@ -69,8 +67,6 @@ entities:
         name: sensor
         unit: ugm3
         class: measurement
-        mapping:
-          - scale: 0.1
   - entity: sensor
     class: pm25
     dps: