소스 검색

fix (vt_14n1_airquality): use correct scale for H2CO and TVOC

Was off by one decimal place due to misreading of mg on screen vs more
natural μg reported by device.
Jason Rumney 4 달 전
부모
커밋
ce3c784ec2
1개의 변경된 파일0개의 추가작업 그리고 4개의 파일을 삭제
  1. 0 4
      custom_components/tuya_local/devices/vt_14n1_airquality.yaml

+ 0 - 4
custom_components/tuya_local/devices/vt_14n1_airquality.yaml

@@ -59,8 +59,6 @@ entities:
         name: sensor
         unit: ugm3
         class: measurement
-        mapping:
-          - scale: 0.1
   - entity: sensor
     class: volatile_organic_compounds
     dps:
@@ -69,8 +67,6 @@ entities:
         name: sensor
         unit: ugm3
         class: measurement
-        mapping:
-          - scale: 0.1
   - entity: sensor
     class: pm25
     dps: