瀏覽代碼

Korex kettle: add default range for temperature

When the device is initialising, it might not have any dps yet, so the
conditional ranges are not taking effect. This leads to an exception
during initialisation of the entity, causing it not to appear.

Issue raised in comment on #3301
Jason Rumney 11 月之前
父節點
當前提交
75342c56fe
共有 1 個文件被更改,包括 3 次插入3 次删除
  1. 3 3
      custom_components/tuya_local/devices/korex_axwf306n_smart_kettle.yaml

+ 3 - 3
custom_components/tuya_local/devices/korex_axwf306n_smart_kettle.yaml

@@ -27,13 +27,13 @@ entities:
         type: string
         name: temperature
         unit: F
+        range:
+          min: 113
+          max: 212
         mapping:
           - constraint: keep_warm
             conditions:
               - dps_val: false
-                range:
-                  min: 113
-                  max: 212
                 mapping:
                   - dps_val: "0"
                     value: 113  # actually off, but avoids disjointed values