Korex kettle: add default range for temperature

When the device is initialising, it might not have any dps yet, so the
conditional ranges are not taking effect. This leads to an exception
during initialisation of the entity, causing it not to appear.

Issue raised in comment on #3301
Jason Rumney преди 11 месеца
родител
ревизия
75342c56fe
променени са 1 файла, в които са добавени 3 реда и са изтрити 3 реда
  1. 3 3
      custom_components/tuya_local/devices/korex_axwf306n_smart_kettle.yaml

+ 3 - 3
custom_components/tuya_local/devices/korex_axwf306n_smart_kettle.yaml

@@ -27,13 +27,13 @@ entities:
         type: string
         name: temperature
         unit: F
+        range:
+          min: 113
+          max: 212
         mapping:
           - constraint: keep_warm
             conditions:
               - dps_val: false
-                range:
-                  min: 113
-                  max: 212
                 mapping:
                   - dps_val: "0"
                     value: 113  # actually off, but avoids disjointed values