瀏覽代碼

climate: always return OFF for action when the mode is off.

This should allow simplification of some configs, as the off switch
no longer needs to be considered in the config.

This may also free up the constraint to be used for more complex reporting.
Jason Rumney 1 年之前
父節點
當前提交
0e55258aa0
共有 1 個文件被更改,包括 3 次插入0 次删除
  1. 3 0
      custom_components/tuya_local/climate.py

+ 3 - 0
custom_components/tuya_local/climate.py

@@ -314,6 +314,9 @@ class TuyaLocalClimate(TuyaLocalEntity, ClimateEntity):
         """Return the current HVAC action."""
         if self._hvac_action_dps is None:
             return None
+        if self.hvac_mode is HVACMode.OFF:
+            return HVACAction.OFF
+
         action = self._hvac_action_dps.get_value(self._device)
         try:
             return HVACAction(action) if action else None