소스 검색

climate: always return OFF for action when the mode is off.

This should allow simplification of some configs, as the off switch
no longer needs to be considered in the config.

This may also free up the constraint to be used for more complex reporting.
Jason Rumney 1 년 전
부모
커밋
0e55258aa0
1개의 변경된 파일3개의 추가작업 그리고 0개의 파일을 삭제
  1. 3 0
      custom_components/tuya_local/climate.py

+ 3 - 0
custom_components/tuya_local/climate.py

@@ -314,6 +314,9 @@ class TuyaLocalClimate(TuyaLocalEntity, ClimateEntity):
         """Return the current HVAC action."""
         if self._hvac_action_dps is None:
             return None
+        if self.hvac_mode is HVACMode.OFF:
+            return HVACAction.OFF
+
         action = self._hvac_action_dps.get_value(self._device)
         try:
             return HVACAction(action) if action else None