| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277 |
- name: EV charger
- primary_entity:
- entity: sensor
- class: energy
- dps:
- - id: 1
- optional: true
- type: integer
- name: sensor
- unit: kWh
- mapping:
- - scale: 100
- class: total_increasing
- secondary_entities:
- - entity: sensor
- name: Status
- icon: "mdi:ev-station"
- class: enum
- dps:
- - id: 3
- type: string
- name: sensor
- mapping:
- - dps_val: charger_free
- value: Available
- - dps_val: charger_insert
- value: Plugged in
- - dps_val: charger_free_fault
- value: Fault (unplugged)
- - dps_val: charger_wait
- value: Waiting
- - dps_val: charger_charging
- value: Charging
- - dps_val: charger_pause
- value: Paused
- - dps_val: charger_end
- value: Finished
- - dps_val: charger_fault
- value: Error
- - id: 11
- optional: true
- type: string
- name: alarm_set_1
- - id: 12
- optional: true
- type: string
- name: alarm_set_2
- - id: 19
- optional: true
- type: string
- name: local_timer
- - id: 23
- type: string
- name: system_version
- - id: 33
- optional: true
- type: string
- name: mode_set
- - entity: number
- name: Charging current
- class: current
- category: config
- dps:
- - id: 4
- type: integer
- name: value
- unit: A
- range:
- min: 1
- max: 255
- - entity: sensor
- class: power
- category: diagnostic
- dps:
- - id: 5
- optional: true
- type: integer
- name: sensor
- unit: kW
- mapping:
- - scale: 1000
- class: measurement
- - entity: sensor
- name: Phase A voltage
- class: voltage
- category: diagnostic
- dps:
- - id: 6
- type: base64
- optional: true
- name: sensor
- unit: V
- class: measurement
- mapping:
- - mask: "FFFF000000000000"
- scale: 10
- - entity: sensor
- name: Phase A current
- class: current
- category: diagnostic
- dps:
- - id: 6
- type: base64
- optional: true
- name: sensor
- unit: A
- class: measurement
- mapping:
- - mask: "0000FFFFFF000000"
- scale: 1000
- - entity: sensor
- name: Phase A power
- class: power
- category: diagnostic
- dps:
- - id: 6
- type: base64
- optional: true
- name: sensor
- unit: kW
- class: measurement
- mapping:
- - mask: "0000000000FFFFFF"
- scale: 1000
- - entity: sensor
- name: Total power
- class: power
- category: diagnostic
- dps:
- - id: 9
- type: integer
- name: sensor
- unit: kW
- class: measurement
- mapping:
- - scale: 1000
- - entity: binary_sensor
- class: problem
- category: diagnostic
- dps:
- - id: 10
- type: bitfield
- name: sensor
- mapping:
- - dps_val: 0
- value: false
- - value: true
- - id: 10
- type: bitfield
- name: fault_code
- - entity: sensor
- name: Connection
- icon: "mdi:ev-plug-type2"
- class: enum
- category: diagnostic
- dps:
- - id: 13
- type: string
- name: sensor
- mapping:
- - dps_val: controlpi_12v
- value: Standby
- - dps_val: controlpi_12v_pwm
- value: Communication initialising
- - dps_val: controlpi_9v
- value: Vehicle detected
- - dps_val: controlpi_9v_pwm
- value: Vehicle connected
- - dps_val: controlpi_6v
- value: Ready to charge
- - dps_val: controlpi_6v_pwm
- value: Charging
- - dps_val: controlpi_error
- value: Error
- - entity: select
- name: Charging mode
- icon: "mdi:ev-station"
- category: config
- dps:
- - id: 14
- type: string
- name: option
- mapping:
- - dps_val: charge_now
- value: Immediate
- - dps_val: charge_pct
- value: Charge to percent
- - dps_val: charge_energy
- value: Fixed charge
- - dps_val: charge_schedule
- value: Scheduled charge
- - dps_val: charge_delay
- value: Delayed charge
- - entity: sensor
- name: Remaining
- class: energy_storage
- category: diagnostic
- dps:
- - id: 15
- optional: true
- type: integer
- name: sensor
- unit: kWh
- class: measurement
- mapping:
- - scale: 1000
- - entity: button
- name: Clear energy
- class: reestart
- category: config
- dps:
- - id: 16
- type: boolean
- name: button
- - entity: number
- name: Fixed charge
- class: energy_storage
- category: config
- dps:
- - id: 17
- type: integer
- name: value
- unit: kWh
- mapping:
- - scale: 100
- range:
- min: 1
- max: 2000000
- - entity: switch
- icon: "mdi:ev-station"
- dps:
- - id: 18
- type: boolean
- name: switch
- - entity: sensor
- name: Temperature
- class: temperature
- category: diagnostic
- dps:
- - id: 24
- type: integer
- name: sensor
- unit: C
- - entity: sensor
- name: Charge
- class: energy_storage
- dps:
- - id: 25
- type: integer
- name: sensor
- unit: kWh
- mapping:
- - scale: 100
- - entity: binary_sensor
- class: connectivity
- category: diagnostic
- dps:
- - id: 27
- type: string
- name: sensor
- mapping:
- - dps_val: online
- value: true
- - dps_val: offline
- value: false
- - entity: number
- name: Delayed charge timer
- category: config
- translation_key: timer
- dps:
- - id: 28
- type: integer
- name: value
- unit: h
- range:
- min: 0
- max: 12
|