cleverio_pf100_petfeeder.yaml 2.3 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117
  1. name: Pet feeder
  2. products:
  3. - id: wfkzyy0evslzsmoi
  4. manufacturer: Cleverio
  5. model: PF100
  6. entities:
  7. - entity: number
  8. name: Manual feed
  9. icon: "mdi:food-drumstick"
  10. dps:
  11. - id: 3
  12. type: integer
  13. name: value
  14. range:
  15. min: 1
  16. max: 20
  17. - id: 1
  18. type: string
  19. optional: true
  20. name: meal_plan
  21. - id: 103
  22. type: string
  23. name: mode
  24. - entity: button
  25. translation_key: factory_reset
  26. category: config
  27. dps:
  28. - id: 9
  29. type: boolean
  30. optional: true
  31. name: button
  32. - entity: sensor
  33. class: battery
  34. category: diagnostic
  35. dps:
  36. - id: 11
  37. type: integer
  38. name: sensor
  39. unit: "%"
  40. class: measurement
  41. - id: 116
  42. type: string
  43. name: capacity
  44. - entity: binary_sensor
  45. class: battery_charging
  46. category: diagnostic
  47. dps:
  48. - id: 12
  49. type: boolean
  50. name: sensor
  51. - entity: binary_sensor
  52. class: problem
  53. category: diagnostic
  54. dps:
  55. - id: 14
  56. type: bitfield
  57. name: sensor
  58. mapping:
  59. - dps_val: 0
  60. value: false
  61. - value: true
  62. - id: 14
  63. type: bitfield
  64. name: fault_code
  65. - entity: sensor
  66. name: Last feed
  67. icon: "mdi:food-drumstick"
  68. category: diagnostic
  69. dps:
  70. - id: 15
  71. type: integer
  72. name: sensor
  73. unit: portions
  74. - entity: light
  75. translation_key: indicator
  76. category: config
  77. dps:
  78. - id: 19
  79. type: boolean
  80. name: switch
  81. - entity: binary_sensor
  82. class: plug
  83. category: diagnostic
  84. dps:
  85. - id: 101
  86. type: string
  87. name: sensor
  88. mapping:
  89. - dps_val: no_adapter
  90. value: false
  91. - value: true
  92. - entity: binary_sensor
  93. class: power
  94. category: diagnostic
  95. dps:
  96. - id: 101
  97. type: string
  98. name: sensor
  99. mapping:
  100. - dps_val: ac_power_on
  101. value: true
  102. - value: false
  103. - entity: number
  104. name: Volume
  105. category: config
  106. icon: "mdi:volume-high"
  107. dps:
  108. - id: 112
  109. type: integer
  110. name: value
  111. unit: "%"
  112. precision: 0
  113. range:
  114. min: 0
  115. max: 3
  116. mapping:
  117. - scale: 0.03