arlec_panel_heater.yaml 1.7 KB

12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273747576777879
  1. name: Heater
  2. products:
  3. - id: 70kki9an9nr0oqbj
  4. manufacturer: Arlec
  5. name: "2400W panel heater"
  6. entities:
  7. - entity: climate
  8. translation_only_key: heater
  9. dps:
  10. - id: 1
  11. name: hvac_mode
  12. type: boolean
  13. mapping:
  14. - dps_val: true
  15. value: "heat"
  16. - dps_val: false
  17. value: "off"
  18. - id: 2
  19. name: temperature
  20. type: integer
  21. unit: C
  22. range:
  23. min: 5
  24. max: 35
  25. - id: 3
  26. name: current_temperature
  27. type: integer
  28. - id: 4
  29. name: preset_mode
  30. type: string
  31. mapping:
  32. - dps_val: low
  33. value: eco
  34. - dps_val: high
  35. value: boost
  36. - dps_val: af
  37. value: away
  38. - entity: lock
  39. translation_key: child_lock
  40. category: config
  41. dps:
  42. - id: 6
  43. type: boolean
  44. name: lock
  45. # can be 7
  46. optional: true
  47. mapping:
  48. - dps_val: null
  49. value_redirect: alternate
  50. - id: 7
  51. type: boolean
  52. optional: true
  53. name: alternate
  54. - entity: number
  55. translation_key: timer
  56. class: duration
  57. category: config
  58. dps:
  59. - id: 10
  60. type: integer
  61. name: value
  62. unit: hour
  63. range:
  64. min: 0
  65. max: 24
  66. - entity: binary_sensor
  67. class: problem
  68. category: diagnostic
  69. dps:
  70. - id: 12
  71. type: bitfield
  72. name: sensor
  73. mapping:
  74. - dps_val: 0
  75. value: false
  76. - value: true
  77. - id: 12
  78. type: bitfield
  79. name: fault_code