hydrotherm_dynamic_x8_water_heater.yaml 1.1 KB

1234567891011121314151617181920212223242526272829303132333435363738394041424344454647484950515253
  1. name: Hydrotherm DYNAMIC/X8
  2. primary_entity:
  3. entity: water_heater
  4. dps:
  5. - id: 1
  6. type: boolean
  7. name: operation_mode
  8. mapping:
  9. - dps_val: false
  10. value: "off"
  11. - dps_val: true
  12. constraint: work_mode
  13. conditions:
  14. - dps_val: ECO
  15. value: eco
  16. - dps_val: STANDARD
  17. value: heat_pump
  18. - dps_val: HYBRID
  19. value: high_demand
  20. - dps_val: HYBRID1
  21. value: performance
  22. - dps_val: ELEMENT
  23. value: electric
  24. - id: 2
  25. type: integer
  26. name: temperature
  27. range:
  28. min: 15
  29. max: 75
  30. readonly: true
  31. - id: 3
  32. type: integer
  33. name: current_temperature
  34. - id: 4
  35. type: string
  36. name: work_mode
  37. hidden: true
  38. - id: 21
  39. type: bitfield
  40. name: fault_code
  41. secondary_entities:
  42. - entity: binary_sensor
  43. class: problem
  44. name: Fault
  45. category: diagnostic
  46. dps:
  47. - id: 21
  48. type: bitfield
  49. name: sensor
  50. mapping:
  51. - dps_val: 0
  52. value: false
  53. - value: true