evsun_evcharger.yaml 5.9 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277
  1. name: EV charger
  2. entities:
  3. - entity: sensor
  4. class: energy
  5. dps:
  6. - id: 1
  7. optional: true
  8. type: integer
  9. name: sensor
  10. unit: kWh
  11. mapping:
  12. - scale: 100
  13. class: total_increasing
  14. - entity: sensor
  15. translation_key: status
  16. icon: "mdi:ev-station"
  17. class: enum
  18. dps:
  19. - id: 3
  20. type: string
  21. name: sensor
  22. mapping:
  23. - dps_val: charger_free
  24. value: available
  25. - dps_val: charger_insert
  26. value: plugged_in
  27. - dps_val: charger_free_fault
  28. value: fault_unplugged
  29. - dps_val: charger_wait
  30. value: waiting
  31. - dps_val: charger_charging
  32. value: charging
  33. - dps_val: charger_pause
  34. value: paused
  35. - dps_val: charger_end
  36. value: charged
  37. - dps_val: charger_fault
  38. value: fault
  39. - id: 11
  40. optional: true
  41. type: string
  42. name: alarm_set_1
  43. - id: 12
  44. optional: true
  45. type: string
  46. name: alarm_set_2
  47. - id: 19
  48. optional: true
  49. type: string
  50. name: local_timer
  51. - id: 23
  52. type: string
  53. name: system_version
  54. - id: 33
  55. optional: true
  56. type: string
  57. name: mode_set
  58. - entity: number
  59. name: Charging current
  60. class: current
  61. category: config
  62. dps:
  63. - id: 4
  64. type: integer
  65. name: value
  66. unit: A
  67. range:
  68. min: 1
  69. max: 255
  70. - entity: sensor
  71. class: power
  72. category: diagnostic
  73. dps:
  74. - id: 5
  75. optional: true
  76. type: integer
  77. name: sensor
  78. unit: kW
  79. mapping:
  80. - scale: 1000
  81. class: measurement
  82. - entity: sensor
  83. name: Phase A voltage
  84. class: voltage
  85. category: diagnostic
  86. dps:
  87. - id: 6
  88. type: base64
  89. optional: true
  90. name: sensor
  91. unit: V
  92. class: measurement
  93. mask: "FFFF000000000000"
  94. mapping:
  95. - scale: 10
  96. - entity: sensor
  97. name: Phase A current
  98. class: current
  99. category: diagnostic
  100. dps:
  101. - id: 6
  102. type: base64
  103. optional: true
  104. name: sensor
  105. unit: A
  106. class: measurement
  107. mask: "0000FFFFFF000000"
  108. mapping:
  109. - scale: 1000
  110. - entity: sensor
  111. name: Phase A power
  112. class: power
  113. category: diagnostic
  114. dps:
  115. - id: 6
  116. type: base64
  117. optional: true
  118. name: sensor
  119. unit: kW
  120. class: measurement
  121. mask: "0000000000FFFFFF"
  122. mapping:
  123. - scale: 1000
  124. - entity: sensor
  125. name: Total power
  126. class: power
  127. category: diagnostic
  128. dps:
  129. - id: 9
  130. type: integer
  131. name: sensor
  132. unit: kW
  133. class: measurement
  134. mapping:
  135. - scale: 1000
  136. - entity: binary_sensor
  137. class: problem
  138. category: diagnostic
  139. dps:
  140. - id: 10
  141. type: bitfield
  142. name: sensor
  143. mapping:
  144. - dps_val: 0
  145. value: false
  146. - value: true
  147. - id: 10
  148. type: bitfield
  149. name: fault_code
  150. - entity: sensor
  151. name: Connection
  152. icon: "mdi:ev-plug-type2"
  153. class: enum
  154. category: diagnostic
  155. dps:
  156. - id: 13
  157. type: string
  158. name: sensor
  159. mapping:
  160. - dps_val: controlpi_12v
  161. value: Standby
  162. - dps_val: controlpi_12v_pwm
  163. value: Communication initialising
  164. - dps_val: controlpi_9v
  165. value: Vehicle detected
  166. - dps_val: controlpi_9v_pwm
  167. value: Vehicle connected
  168. - dps_val: controlpi_6v
  169. value: Ready to charge
  170. - dps_val: controlpi_6v_pwm
  171. value: Charging
  172. - dps_val: controlpi_error
  173. value: Error
  174. - entity: select
  175. name: Charging mode
  176. icon: "mdi:ev-station"
  177. category: config
  178. dps:
  179. - id: 14
  180. type: string
  181. name: option
  182. mapping:
  183. - dps_val: charge_now
  184. value: Immediate
  185. - dps_val: charge_pct
  186. value: Charge to percent
  187. - dps_val: charge_energy
  188. value: Fixed charge
  189. - dps_val: charge_schedule
  190. value: Scheduled charge
  191. - dps_val: charge_delay
  192. value: Delayed charge
  193. - entity: sensor
  194. name: Remaining
  195. class: energy_storage
  196. category: diagnostic
  197. dps:
  198. - id: 15
  199. optional: true
  200. type: integer
  201. name: sensor
  202. unit: kWh
  203. class: measurement
  204. mapping:
  205. - scale: 1000
  206. - entity: button
  207. name: Clear energy
  208. class: reestart
  209. category: config
  210. dps:
  211. - id: 16
  212. type: boolean
  213. name: button
  214. - entity: number
  215. name: Fixed charge
  216. class: energy_storage
  217. category: config
  218. dps:
  219. - id: 17
  220. type: integer
  221. name: value
  222. unit: kWh
  223. mapping:
  224. - scale: 100
  225. range:
  226. min: 1
  227. max: 2000000
  228. - entity: switch
  229. icon: "mdi:ev-station"
  230. dps:
  231. - id: 18
  232. type: boolean
  233. name: switch
  234. - entity: sensor
  235. name: Temperature
  236. class: temperature
  237. category: diagnostic
  238. dps:
  239. - id: 24
  240. type: integer
  241. name: sensor
  242. unit: C
  243. - entity: sensor
  244. name: Charge
  245. class: energy_storage
  246. dps:
  247. - id: 25
  248. type: integer
  249. name: sensor
  250. unit: kWh
  251. mapping:
  252. - scale: 100
  253. - entity: binary_sensor
  254. class: connectivity
  255. category: diagnostic
  256. dps:
  257. - id: 27
  258. type: string
  259. name: sensor
  260. mapping:
  261. - dps_val: online
  262. value: true
  263. - dps_val: offline
  264. value: false
  265. - entity: number
  266. name: Delayed charge timer
  267. category: config
  268. class: duration
  269. translation_key: timer
  270. dps:
  271. - id: 28
  272. type: integer
  273. name: value
  274. unit: h
  275. range:
  276. min: 0
  277. max: 12