weau_pool_heatpump13kW.yaml 3.3 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163
  1. name: W'Eau pool heatpump 13kW
  2. primary_entity:
  3. entity: climate
  4. translation_key: pool_heatpump
  5. dps:
  6. - id: 1
  7. type: boolean
  8. name: hvac_mode
  9. mapping:
  10. - dps_val: false
  11. value: "off"
  12. - dps_val: true
  13. constraint: preset_mode
  14. conditions:
  15. - dps_val: eco
  16. value: heat
  17. - dps_val: hot
  18. value: heat
  19. - dps_val: cold
  20. value: cool
  21. - dps_val: auto
  22. value: heat_cool
  23. - id: 2
  24. type: integer
  25. name: temperature
  26. range:
  27. min: 7
  28. max: 60
  29. - id: 3
  30. type: integer
  31. name: current_temperature
  32. - id: 4
  33. type: string
  34. name: preset_mode
  35. mapping:
  36. - dps_val: hot
  37. value: quick_heat
  38. - dps_val: eco
  39. value: quiet_heat
  40. - dps_val: cold
  41. value: quiet_cool
  42. - dps_val: auto
  43. value: auto
  44. - id: 6
  45. name: fault
  46. type: bitfield
  47. - id: 101
  48. name: unknown_101
  49. type: integer
  50. class: measurement
  51. - id: 103
  52. name: unknown_103
  53. type: integer
  54. class: measurement
  55. - id: 106
  56. name: unknown_106
  57. type: integer
  58. class: measurement
  59. - id: 110
  60. name: unknown_110
  61. type: integer
  62. class: measurement
  63. - id: 111
  64. name: unknown_111
  65. type: integer
  66. class: measurement
  67. - id: 113
  68. name: unknown_113
  69. type: boolean
  70. - id: 114
  71. name: unknown_114
  72. type: boolean
  73. - id: 117
  74. name: unknown_117
  75. type: boolean
  76. - id: 118
  77. name: unknown_118
  78. type: boolean
  79. secondary_entities:
  80. - entity: binary_sensor
  81. class: problem
  82. name: Fault
  83. category: diagnostic
  84. dps:
  85. - id: 6
  86. type: bitfield
  87. name: sensor
  88. mapping:
  89. - dps_val: 0
  90. value: false
  91. - value: true
  92. - entity: sensor
  93. class: temperature
  94. name: Air inlet temperature
  95. dps:
  96. - id: 102
  97. name: sensor
  98. type: integer
  99. unit: "°C"
  100. class: measurement
  101. - entity: sensor
  102. class: temperature
  103. name: Gas out temperature
  104. dps:
  105. - id: 104
  106. name: sensor
  107. type: integer
  108. unit: "°C"
  109. class: measurement
  110. - entity: sensor
  111. class: temperature
  112. name: Air outlet temperature
  113. dps:
  114. - id: 105
  115. name: sensor
  116. type: integer
  117. unit: "°C"
  118. class: measurement
  119. - entity: sensor
  120. class: temperature
  121. name: Condensor temperature
  122. dps:
  123. - id: 107
  124. name: sensor
  125. type: integer
  126. unit: "°C"
  127. class: measurement
  128. - entity: sensor
  129. class: temperature
  130. name: Water inlet temperature
  131. dps:
  132. - id: 108
  133. name: sensor
  134. type: integer
  135. unit: "°C"
  136. class: measurement
  137. - entity: sensor
  138. class: temperature
  139. name: Water outlet temperature
  140. dps:
  141. - id: 109
  142. name: sensor
  143. type: integer
  144. unit: "°C"
  145. class: measurement
  146. - entity: binary_sensor
  147. name: Compressor active
  148. dps:
  149. - id: 112
  150. type: boolean
  151. name: sensor
  152. - entity: binary_sensor
  153. name: Fan active
  154. dps:
  155. - id: 115
  156. type: boolean
  157. name: sensor
  158. - entity: binary_sensor
  159. name: Circulation active
  160. dps:
  161. - id: 116