aubess_1gang_switch.yaml 1.8 KB

1234567891011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556575859606162636465666768697071727374757677787980818283848586878889909192
  1. name: Aubess energy monitor switch
  2. primary_entity:
  3. entity: switch
  4. dps:
  5. - id: 1
  6. name: switch
  7. type: boolean
  8. - id: 24
  9. name: test_bit
  10. type: integer
  11. - id: 42
  12. name: random_time
  13. type: string
  14. - id: 43
  15. name: cycle_time
  16. type: string
  17. - id: 44
  18. name: switch_inching
  19. type: string
  20. secondary_entities:
  21. - entity: number
  22. name: Timer
  23. category: config
  24. icon: "mdi:timer"
  25. dps:
  26. - id: 9
  27. name: value
  28. type: integer
  29. range:
  30. min: 0
  31. max: 86400
  32. mapping:
  33. - scale: 60
  34. step: 60
  35. - entity: select
  36. name: Restore power state
  37. category: config
  38. icon: "mdi:toggle-switch"
  39. dps:
  40. - id: 38
  41. type: string
  42. name: option
  43. mapping:
  44. - dps_val: "0"
  45. value: "Off"
  46. - dps_val: "1"
  47. value: "On"
  48. - dps_val: "2"
  49. value: Remember last state
  50. - entity: sensor
  51. name: Energy
  52. category: diagnostic
  53. dps:
  54. - id: 20
  55. name: sensor
  56. type: integer
  57. optional: true
  58. unit: Wh
  59. - entity: sensor
  60. class: current
  61. category: diagnostic
  62. dps:
  63. - id: 21
  64. name: sensor
  65. type: integer
  66. class: measurement
  67. force: true
  68. unit: mA
  69. - entity: sensor
  70. class: power
  71. category: diagnostic
  72. dps:
  73. - id: 22
  74. name: sensor
  75. type: integer
  76. class: measurement
  77. force: true
  78. unit: W
  79. mapping:
  80. - scale: 10
  81. - entity: sensor
  82. class: voltage
  83. category: diagnostic
  84. dps:
  85. - id: 23
  86. name: sensor
  87. type: integer
  88. force: true
  89. class: measurement
  90. unit: V
  91. mapping:
  92. - scale: 10