smartplugv2_energyv3.yaml 3.3 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167
  1. name: Energy monitoring smartplug
  2. products:
  3. - id: 2iepauebcvo74ujc
  4. name: Aubess 20A
  5. - id: wrz6vzch8htux2zp
  6. name: Elivco CB2S-16DL
  7. primary_entity:
  8. entity: switch
  9. class: outlet
  10. dps:
  11. - id: 1
  12. type: boolean
  13. name: switch
  14. - id: 21
  15. type: integer
  16. name: test_bit
  17. - id: 26
  18. type: bitfield
  19. name: fault_code
  20. - id: 42
  21. type: base64
  22. name: cycle_timer
  23. optional: true
  24. - id: 43
  25. type: base64
  26. name: random_timer
  27. optional: true
  28. - id: 44
  29. type: base64
  30. name: inching
  31. optional: true
  32. secondary_entities:
  33. - entity: number
  34. category: config
  35. name: Timer
  36. icon: "mdi:timer"
  37. dps:
  38. - id: 9
  39. type: integer
  40. name: value
  41. unit: min
  42. range:
  43. min: 0
  44. max: 86400
  45. mapping:
  46. - scale: 60
  47. step: 60
  48. - entity: sensor
  49. category: diagnostic
  50. name: Energy
  51. dps:
  52. - id: 17
  53. name: sensor
  54. type: integer
  55. unit: Wh
  56. optional: true
  57. - id: 25
  58. type: integer
  59. name: calibration
  60. # seems to be present even when 17 is missing, but for consistency
  61. optional: true
  62. - entity: sensor
  63. category: diagnostic
  64. class: current
  65. name: Current
  66. dps:
  67. - id: 18
  68. name: sensor
  69. type: integer
  70. class: measurement
  71. force: true
  72. unit: mA
  73. - id: 23
  74. type: integer
  75. name: calibration
  76. - entity: sensor
  77. category: diagnostic
  78. class: power
  79. name: Power
  80. dps:
  81. - id: 19
  82. name: sensor
  83. type: integer
  84. class: measurement
  85. force: true
  86. unit: W
  87. mapping:
  88. - scale: 10
  89. - id: 24
  90. type: integer
  91. name: calibration
  92. - entity: sensor
  93. category: diagnostic
  94. class: voltage
  95. name: Voltage
  96. dps:
  97. - id: 20
  98. name: sensor
  99. type: integer
  100. class: measurement
  101. force: true
  102. unit: V
  103. mapping:
  104. - scale: 10
  105. - id: 22
  106. type: integer
  107. name: calibration
  108. - entity: binary_sensor
  109. class: problem
  110. category: diagnostic
  111. name: Error
  112. dps:
  113. - id: 26
  114. type: bitfield
  115. name: sensor
  116. mapping:
  117. - dps_val: 0
  118. value: false
  119. - value: true
  120. - entity: select
  121. category: config
  122. name: Initial state
  123. icon: "mdi:toggle-switch"
  124. dps:
  125. - id: 38
  126. type: string
  127. name: option
  128. mapping:
  129. - dps_val: "on"
  130. value: "On"
  131. - dps_val: "off"
  132. value: "Off"
  133. - dps_val: memory
  134. value: "Last State"
  135. - entity: lock
  136. name: Child Lock
  137. category: config
  138. icon: "mdi:hand-back-right-off"
  139. dps:
  140. - id: 41
  141. type: boolean
  142. name: lock
  143. - entity: select
  144. name: Light mode
  145. category: config
  146. icon: "mdi:lightbulb"
  147. dps:
  148. - id: 40
  149. type: string
  150. name: option
  151. mapping:
  152. - dps_val: relay
  153. value: State
  154. - dps_val: pos
  155. value: Position
  156. - dps_val: none
  157. value: "Off"
  158. - dps_val: "on"
  159. value: "On"
  160. - entity: switch
  161. name: Overcharge protection
  162. category: config
  163. dps:
  164. - id: 39
  165. type: boolean