| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158 |
- name: Circuit breaker energy meter
- products:
- - id: rrmpzckqm5pfd642
- name: TOMPD-63LW
- - id: psjg8ldomxnelfp5
- name: TOMZN-63A
- primary_entity:
- entity: switch
- dps:
- - id: 16
- name: switch
- type: boolean
- - id: 17
- name: alarm_set_1
- optional: true
- type: string
- - id: 18
- name: alarm_set_2
- optional: true
- type: string
- - id: 6
- name: phase_a
- type: base64
- optional: true
- force: true
- - id: 9
- name: fault
- type: bitfield
- optional: true
- mapping:
- - dps_val: 0
- value: OK
- - id: 19
- name: breaker_number
- type: string
- secondary_entities:
- - entity: switch
- name: Prepayment
- icon: "mdi:cash-multiple"
- category: config
- dps:
- - id: 11
- type: boolean
- name: switch
- - entity: button
- name: Energy reset
- class: restart
- category: config
- dps:
- - id: 12
- type: boolean
- name: button
- optional: true
- - entity: button
- name: Refresh sensors
- class: restart
- category: config
- dps:
- - id: 106
- type: boolean
- name: button
- optional: true
- - entity: sensor
- name: Balance energy
- category: diagnostic
- class: energy_storage
- dps:
- - id: 13
- type: integer
- name: sensor
- unit: kWh
- mapping:
- - scale: 10
- - entity: number
- name: Charge energy
- category: config
- class: energy_storage
- icon: "mdi:cash"
- dps:
- - id: 14
- type: integer
- name: value
- optional: true
- unit: kWh
- range:
- min: 0
- max: 99999
- mapping:
- - scale: 10
- - entity: sensor
- name: Leakage current
- class: current
- category: diagnostic
- dps:
- - id: 15
- type: integer
- name: sensor
- unit: mA
- class: measurement
- optional: true
- - entity: button
- name: Earth leak test
- icon: "mdi:current-ac"
- category: config
- dps:
- - id: 21
- type: boolean
- name: button
- optional: true
- - entity: sensor
- class: energy
- dps:
- - id: 1
- type: integer
- name: sensor
- unit: kWh
- class: total_increasing
- mapping:
- - scale: 100
- - entity: sensor
- name: Voltage A
- class: voltage
- category: diagnostic
- dps:
- - id: 6
- type: base64
- name: sensor
- optional: true
- unit: V
- mapping:
- - mask: "FFFF000000000000"
- scale: 10
- - entity: sensor
- name: Current A
- class: current
- category: diagnostic
- dps:
- - id: 6
- type: base64
- name: sensor
- optional: true
- unit: A
- mapping:
- - mask: "0000FFFFFF000000"
- scale: 1000
- - entity: sensor
- name: Power A
- class: power
- category: diagnostic
- dps:
- - id: 6
- type: base64
- name: sensor
- optional: true
- unit: kW
- mapping:
- - mask: "0000000000FFFFFF"
- scale: 1000
|