beca_bhp6000_thermostat_mapped.yaml 1.8 KB

12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273747576777879808182
  1. name: Thermostat
  2. products:
  3. - id: drwezxukumr9ohuh
  4. manufacturer: Beca
  5. model: BHP-6000 (mapped °C)
  6. entities:
  7. - entity: climate
  8. translation_only_key: thermostat
  9. dps:
  10. - id: 2
  11. name: temperature
  12. type: integer
  13. unit: C
  14. precision: 0
  15. range:
  16. min: 42
  17. max: 102
  18. # These mappings are not quite F to C, but appear to be what is used
  19. # by the thermostat when set to C (issue #215)
  20. mapping:
  21. - target_range:
  22. min: 5
  23. max: 35
  24. - id: 3
  25. name: current_temperature
  26. type: integer
  27. precision: 1
  28. range:
  29. min: 41
  30. max: 112
  31. mapping:
  32. - target_range:
  33. min: 5
  34. max: 40.5
  35. - id: 4
  36. name: preset_mode
  37. type: integer
  38. mapping:
  39. - dps_val: 1
  40. value: program
  41. - dps_val: 2
  42. value: temp_override
  43. - dps_val: 3
  44. value: perm_override
  45. - dps_val: 4
  46. value: away
  47. - id: 5
  48. name: hvac_mode
  49. type: integer
  50. mapping:
  51. - dps_val: 1
  52. value: cool
  53. - dps_val: 2
  54. value: heat
  55. - dps_val: 3
  56. value: "off"
  57. - dps_val: 4
  58. value: heat_cool
  59. - dps_val: 5
  60. value: auto
  61. - id: 6
  62. name: fan_mode
  63. type: boolean
  64. mapping:
  65. - dps_val: false
  66. value: auto
  67. - dps_val: true
  68. value: "on"
  69. - entity: lock
  70. translation_key: child_lock
  71. category: config
  72. dps:
  73. - id: 7
  74. name: lock
  75. type: boolean
  76. - entity: light
  77. translation_key: display
  78. category: config
  79. dps:
  80. - id: 1
  81. name: switch