trotec_pac-w_heatpump.yaml 1.7 KB

12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273747576777879808182838485868788
  1. name: Air conditioner
  2. products:
  3. - id: 6r9as02gkiaaxelt
  4. name: Trotec PAC-W 2600 SH
  5. primary_entity:
  6. entity: climate
  7. dps:
  8. - id: 1
  9. type: boolean
  10. name: hvac_mode
  11. mapping:
  12. - dps_val: false
  13. value: "off"
  14. - dps_val: true
  15. constraint: mode
  16. conditions:
  17. - dps_val: COOL
  18. value: cool
  19. - dps_val: DRY
  20. value: dry
  21. - dps_val: FAN
  22. value: fan_only
  23. - dps_val: HEAT
  24. value: heat
  25. - id: 2
  26. type: integer
  27. name: temperature
  28. range:
  29. min: 16
  30. max: 30
  31. unit: C
  32. - id: 3
  33. type: integer
  34. name: current_temperature
  35. - id: 4
  36. type: string
  37. name: mode
  38. hidden: true
  39. - id: 5
  40. name: fan_mode
  41. type: string
  42. mapping:
  43. - dps_val: "1"
  44. value: low
  45. - dps_val: "2"
  46. value: medium
  47. - dps_val: "3"
  48. value: high
  49. - id: 19
  50. name: temperature_unit
  51. type: string
  52. - id: 101
  53. name: sleep
  54. type: boolean
  55. - id: 102
  56. name: defrost
  57. type: boolean
  58. - id: 103
  59. name: timer
  60. type: integer
  61. - id: 104
  62. name: swing_mode
  63. type: boolean
  64. mapping:
  65. - dps_val: true
  66. value: "vertical"
  67. - dps_val: false
  68. value: "off"
  69. - id: 105
  70. name: countdown
  71. type: integer
  72. - id: 106
  73. name: fault_code
  74. type: bitfield
  75. - id: 110
  76. name: model
  77. type: string
  78. - id: 111
  79. name: fault_code2
  80. type: bitfield
  81. secondary_entities:
  82. - entity: switch
  83. translation_key: sleep
  84. category: config
  85. dps:
  86. - id: 101
  87. type: boolean
  88. name: switch