smartplugv2_energyv3.yaml 3.4 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169
  1. name: Energy monitoring smartplug
  2. products:
  3. - id: 2iepauebcvo74ujc
  4. name: Aubess 20A
  5. - id: wrz6vzch8htux2zp
  6. name: Elivco CB2S-16DL
  7. - id: 3lbgj7cu27nsmh0w
  8. name: AT-Q-SY2-JWT
  9. primary_entity:
  10. entity: switch
  11. class: outlet
  12. dps:
  13. - id: 1
  14. type: boolean
  15. name: switch
  16. - id: 21
  17. type: integer
  18. name: test_bit
  19. - id: 26
  20. type: bitfield
  21. name: fault_code
  22. - id: 42
  23. type: base64
  24. name: cycle_timer
  25. optional: true
  26. - id: 43
  27. type: base64
  28. name: random_timer
  29. optional: true
  30. - id: 44
  31. type: base64
  32. name: inching
  33. optional: true
  34. secondary_entities:
  35. - entity: number
  36. category: config
  37. name: Timer
  38. icon: "mdi:timer"
  39. dps:
  40. - id: 9
  41. type: integer
  42. name: value
  43. unit: min
  44. range:
  45. min: 0
  46. max: 86400
  47. mapping:
  48. - scale: 60
  49. step: 60
  50. - entity: sensor
  51. category: diagnostic
  52. name: Energy
  53. dps:
  54. - id: 17
  55. name: sensor
  56. type: integer
  57. unit: Wh
  58. optional: true
  59. - id: 25
  60. type: integer
  61. name: calibration
  62. # seems to be present even when 17 is missing, but for consistency
  63. optional: true
  64. - entity: sensor
  65. category: diagnostic
  66. class: current
  67. name: Current
  68. dps:
  69. - id: 18
  70. name: sensor
  71. type: integer
  72. class: measurement
  73. force: true
  74. unit: mA
  75. - id: 23
  76. type: integer
  77. name: calibration
  78. - entity: sensor
  79. category: diagnostic
  80. class: power
  81. name: Power
  82. dps:
  83. - id: 19
  84. name: sensor
  85. type: integer
  86. class: measurement
  87. force: true
  88. unit: W
  89. mapping:
  90. - scale: 10
  91. - id: 24
  92. type: integer
  93. name: calibration
  94. - entity: sensor
  95. category: diagnostic
  96. class: voltage
  97. name: Voltage
  98. dps:
  99. - id: 20
  100. name: sensor
  101. type: integer
  102. class: measurement
  103. force: true
  104. unit: V
  105. mapping:
  106. - scale: 10
  107. - id: 22
  108. type: integer
  109. name: calibration
  110. - entity: binary_sensor
  111. class: problem
  112. category: diagnostic
  113. name: Error
  114. dps:
  115. - id: 26
  116. type: bitfield
  117. name: sensor
  118. mapping:
  119. - dps_val: 0
  120. value: false
  121. - value: true
  122. - entity: select
  123. category: config
  124. name: Initial state
  125. icon: "mdi:toggle-switch"
  126. dps:
  127. - id: 38
  128. type: string
  129. name: option
  130. mapping:
  131. - dps_val: "on"
  132. value: "On"
  133. - dps_val: "off"
  134. value: "Off"
  135. - dps_val: memory
  136. value: "Last State"
  137. - entity: lock
  138. name: Child Lock
  139. category: config
  140. icon: "mdi:hand-back-right-off"
  141. dps:
  142. - id: 41
  143. type: boolean
  144. name: lock
  145. - entity: select
  146. name: Light mode
  147. category: config
  148. icon: "mdi:lightbulb"
  149. dps:
  150. - id: 40
  151. type: string
  152. name: option
  153. mapping:
  154. - dps_val: relay
  155. value: State
  156. - dps_val: pos
  157. value: Position
  158. - dps_val: none
  159. value: "Off"
  160. - dps_val: "on"
  161. value: "On"
  162. - entity: switch
  163. name: Overcharge protection
  164. category: config
  165. dps:
  166. - id: 39
  167. type: boolean