| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106 |
- name: Water heater
- products:
- - id: lci0ebsz7ftaruaf
- manufacturer: Ferroli
- model: Titano Twin
- model_id: DT EWH
- entities:
- - entity: water_heater
- dps:
- - id: 1
- name: operation_mode
- type: boolean
- mapping:
- - dps_val: false
- value: "off"
- - dps_val: true
- constraint: work_mode
- conditions:
- - dps_val: manual
- value: electric
- - dps_val: eco
- value: eco
- - id: 2
- type: string
- name: work_mode
- hidden: true
- - id: 9
- type: integer
- name: temperature
- range:
- min: 40
- max: 80
- mapping:
- - step: 5
- unit: C
- - id: 10
- type: integer
- name: current_temperature
- - entity: switch
- name: Anti-legionella
- category: config
- dps:
- - id: 4
- type: boolean
- name: switch
- mapping:
- - dps_val: true
- icon: "mdi:shield-cross-outline"
- - dps_val: false
- icon: "mdi:shield-remove-outline"
- - entity: binary_sensor
- class: problem
- category: diagnostic
- dps:
- - id: 101
- type: bitfield
- name: sensor
- mapping:
- - dps_val: 0
- value: false
- - value: true
- - id: 101
- type: bitfield
- name: fault_code
- - id: 101
- type: bitfield
- name: description
- mapping:
- - dps_val: 0
- value: OK
- - dps_val: 1
- value: E2 Operating without water
- - dps_val: 2
- value: E3 NTC temperature sensor
- - dps_val: 4
- value: E4 Water overheating
- - dps_val: 16
- value: E6 clock RTC failure
- - entity: binary_sensor
- name: Heating status
- class: running
- category: diagnostic
- dps:
- - id: 102
- type: string
- name: sensor
- mapping:
- - dps_val: Heating
- value: true
- - value: false
- - entity: binary_sensor
- translation_key: defrost
- category: diagnostic
- dps:
- - id: 103
- type: boolean
- name: sensor
- - entity: sensor
- name: Target temperature
- class: temperature
- category: diagnostic
- dps:
- - id: 104
- type: integer
- name: sensor
- unit: C
|