smartplugv2_energyv3.yaml 3.5 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173
  1. name: Energy monitoring smartplug
  2. products:
  3. - id: 2iepauebcvo74ujc
  4. name: Aubess 20A
  5. - id: wrz6vzch8htux2zp
  6. name: Elivco CB2S-16DL
  7. - id: 3lbgj7cu27nsmh0w
  8. name: AT-Q-SY2-JWT
  9. primary_entity:
  10. entity: switch
  11. class: outlet
  12. dps:
  13. - id: 1
  14. type: boolean
  15. name: switch
  16. - id: 21
  17. type: integer
  18. name: test_bit
  19. - id: 26
  20. type: bitfield
  21. name: fault_code
  22. - id: 42
  23. type: base64
  24. name: cycle_timer
  25. optional: true
  26. - id: 43
  27. type: base64
  28. name: random_timer
  29. optional: true
  30. - id: 44
  31. type: base64
  32. name: inching
  33. optional: true
  34. secondary_entities:
  35. - entity: number
  36. category: config
  37. name: Timer
  38. icon: "mdi:timer"
  39. dps:
  40. - id: 9
  41. type: integer
  42. name: value
  43. unit: min
  44. range:
  45. min: 0
  46. max: 86400
  47. mapping:
  48. - scale: 60
  49. step: 60
  50. - entity: sensor
  51. category: diagnostic
  52. name: Energy
  53. dps:
  54. - id: 17
  55. name: sensor
  56. type: integer
  57. unit: Wh
  58. optional: true
  59. - id: 25
  60. type: integer
  61. name: calibration
  62. # seems to be present even when 17 is missing, but for consistency
  63. optional: true
  64. - entity: sensor
  65. category: diagnostic
  66. class: current
  67. dps:
  68. - id: 18
  69. name: sensor
  70. type: integer
  71. class: measurement
  72. force: true
  73. unit: mA
  74. - id: 23
  75. type: integer
  76. name: calibration
  77. - entity: sensor
  78. category: diagnostic
  79. class: power
  80. dps:
  81. - id: 19
  82. name: sensor
  83. type: integer
  84. class: measurement
  85. force: true
  86. unit: W
  87. mapping:
  88. - scale: 10
  89. constraint: switch
  90. conditions:
  91. - dps_val: false
  92. value: 0
  93. - id: 1
  94. type: boolean
  95. name: switch
  96. - id: 24
  97. type: integer
  98. name: calibration
  99. - entity: sensor
  100. category: diagnostic
  101. class: voltage
  102. dps:
  103. - id: 20
  104. name: sensor
  105. type: integer
  106. class: measurement
  107. force: true
  108. unit: V
  109. mapping:
  110. - scale: 10
  111. - id: 22
  112. type: integer
  113. name: calibration
  114. - entity: binary_sensor
  115. class: problem
  116. category: diagnostic
  117. name: Error
  118. dps:
  119. - id: 26
  120. type: bitfield
  121. name: sensor
  122. mapping:
  123. - dps_val: 0
  124. value: false
  125. - value: true
  126. - entity: select
  127. category: config
  128. name: Initial state
  129. icon: "mdi:toggle-switch"
  130. dps:
  131. - id: 38
  132. type: string
  133. name: option
  134. mapping:
  135. - dps_val: "on"
  136. value: "On"
  137. - dps_val: "off"
  138. value: "Off"
  139. - dps_val: memory
  140. value: "Last State"
  141. - entity: lock
  142. name: Child Lock
  143. category: config
  144. icon: "mdi:hand-back-right-off"
  145. dps:
  146. - id: 41
  147. type: boolean
  148. name: lock
  149. - entity: select
  150. name: Light mode
  151. category: config
  152. icon: "mdi:lightbulb"
  153. dps:
  154. - id: 40
  155. type: string
  156. name: option
  157. mapping:
  158. - dps_val: relay
  159. value: State
  160. - dps_val: pos
  161. value: Position
  162. - dps_val: none
  163. value: "Off"
  164. - dps_val: "on"
  165. value: "On"
  166. - entity: switch
  167. name: Overcharge protection
  168. category: config
  169. dps:
  170. - id: 39
  171. type: boolean
  172. name: switch
  173. optional: true