| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256 |
- name: Dual meter
- products:
- - id: bfa88129148596f2f0oeht
- name: Dcenta dual clamp meter
- primary_entity:
- entity: sensor
- name: Energy consumed
- class: energy
- dps:
- - id: 1
- type: integer
- name: sensor
- unit: kWh
- class: total_increasing
- mapping:
- - scale: 100
- secondary_entities:
- - entity: sensor
- name: Energy produced
- class: energy
- dps:
- - id: 2
- type: integer
- name: sensor
- unit: kWh
- class: total_increasing
- mapping:
- - scale: 100
- - entity: sensor
- name: Energy flow A
- category: diagnostic
- dps:
- - id: 102
- type: string
- name: sensor
- - entity: sensor
- name: Energy flow B
- category: diagnostic
- dps:
- - id: 104
- type: string
- name: sensor
- - entity: sensor
- name: Power A
- class: power
- category: diagnostic
- dps:
- - id: 101
- type: integer
- name: sensor
- unit: W
- class: measurement
- mapping:
- - scale: 10
- - id: 118
- type: integer
- name: calibration
- mapping:
- - scale: 1000
- - entity: sensor
- name: Power B
- class: power
- category: diagnostic
- dps:
- - id: 105
- type: integer
- name: sensor
- unit: W
- class: measurement
- mapping:
- - scale: 10
- - id: 124
- type: integer
- name: calibration
- mapping:
- - scale: 1000
- - entity: sensor
- name: Energy consumed A
- class: energy
- category: diagnostic
- dps:
- - id: 106
- type: integer
- name: sensor
- unit: kWh
- class: total_increasing
- mapping:
- - scale: 100
- - id: 119
- type: integer
- name: calibration
- mapping:
- - scale: 1000
- - entity: sensor
- name: Energy produced A
- class: energy
- category: diagnostic
- dps:
- - id: 107
- type: integer
- name: sensor
- unit: kWh
- class: total_increasing
- mapping:
- - scale: 100
- - id: 127
- type: integer
- name: calibration
- mapping:
- - scale: 1000
- - entity: sensor
- name: Energy consumed B
- class: energy
- category: diagnostic
- dps:
- - id: 108
- type: integer
- name: sensor
- unit: kWh
- class: total_increasing
- mapping:
- - scale: 100
- - id: 125
- type: integer
- name: calibration
- mapping:
- - scale: 1000
- - entity: sensor
- name: Energy produced B
- class: energy
- category: diagnostic
- dps:
- - id: 109
- type: integer
- name: sensor
- unit: kWh
- class: total_increasing
- mapping:
- - scale: 100
- - id: 128
- type: integer
- name: calibration
- mapping:
- - scale: 1000
- - entity: sensor
- name: Power factor A
- class: power_factor
- category: diagnostic
- dps:
- - id: 110
- type: integer
- name: sensor
- unit: "%"
- class: measurement
- - entity: sensor
- class: frequency
- category: diagnostic
- dps:
- - id: 111
- type: integer
- name: sensor
- unit: Hz
- class: measurement
- mapping:
- - scale: 100
- - id: 122
- type: integer
- name: calibration
- mapping:
- - scale: 1000
- - entity: sensor
- class: voltage
- category: diagnostic
- dps:
- - id: 112
- type: integer
- name: sensor
- unit: V
- class: measurement
- mapping:
- - scale: 10
- - id: 116
- type: integer
- name: calibration
- mapping:
- - scale: 1000
- - entity: sensor
- name: Current A
- class: current
- category: diagnostic
- dps:
- - id: 113
- type: integer
- name: sensor
- unit: A
- class: measurement
- mapping:
- - scale: 1000
- - id: 117
- type: integer
- name: calibration
- mapping:
- - scale: 1000
- - entity: sensor
- name: Current B
- class: current
- category: diagnostic
- dps:
- - id: 114
- type: integer
- name: sensor
- unit: A
- class: measurement
- mapping:
- - scale: 1000
- - id: 123
- type: integer
- name: calibration
- mapping:
- - scale: 1000
- - entity: sensor
- name: Total power
- class: power
- category: diagnostic
- dps:
- - id: 115
- type: integer
- name: sensor
- unit: W
- class: measurement
- mapping:
- - scale: 10
- - entity: sensor
- name: Power factor B
- class: power_factor
- category: diagnostic
- dps:
- - id: 121
- type: integer
- name: sensor
- unit: "%"
- class: measurement
- mapping:
- - scale: 100
- - entity: number
- name: Reporting rate
- category: config
- icon: "mdi:timer-refresh"
- dps:
- - id: 129
- type: integer
- name: value
- unit: s
- range:
- min: 3
- max: 60
|