- name: Beca BHP-6000 Thermostat
- primary_entity:
- entity: climate
- dps:
- - id: 1
- name: hvac_mode
- type: boolean
- mapping:
- - dps_val: false
- value: "off"
- - dps_val: true
- value: "heat_cool"
- - id: 2
- name: temperature
- type: integer
- constraint: temperature_unit
- conditions:
- - dps_val: 1
- range:
- min: 5
- max: 35
- - dps_val: 2
- range:
- min: 5
- max: 35
- - dps_val: 3
- range:
- min: 40
- max: 95
- - id: 3
- name: current_temperature
- type: integer
- - id: 4
- name: level
- type: integer
- - id: 5
- name: temperature_unit
- type: integer
- mapping:
- - dps_val: 1
- value: C
- - dps_val: 2
- value: C
- - dps_val: 3
- value: F
- - id: 6
- name: preset_mode
- type: boolean
- mapping:
- - dps_val: false
- value: normal
- - dps_val: true
- value: eco
- secondary_entities:
- - entity: lock
- name: Child Lock
- dps:
- - id: 7
- name: lock
- type: boolean
|