name: Thermostat # products: Nashone MTS-700-WB entities: - entity: climate dps: - id: 1 type: boolean name: hvac_mode mapping: - dps_val: false value: "off" - dps_val: true constraint: mode conditions: - dps_val: cold value: cool - dps_val: hot value: heat - id: 2 type: string name: mode hidden: true - id: 3 type: string name: work_state - id: 16 type: integer name: temperature range: min: -20 max: 105 mapping: - constraint: temperature_unit conditions: - dps_val: f value_redirect: temp_f range: min: -4 max: 221 - id: 17 type: integer name: temp_f range: min: -4 max: 221 hidden: true - id: 23 type: string name: temperature_unit mapping: - dps_val: c value: C - dps_val: f value: F - id: 24 type: integer name: current_temperature mapping: - constraint: temperature_unit conditions: - dps_val: f value_redirect: temp_current_f - id: 29 type: integer name: temp_current_f hidden: true - entity: number category: config translation_key: temperature_calibration dps: - id: 27 type: integer name: value unit: ° range: min: -5 max: 5 - entity: button translation_key: factory_reset category: config dps: - id: 39 type: boolean name: button - entity: select translation_key: timer category: config dps: - id: 41 type: string name: option mapping: - dps_val: cancel value: cancel - dps_val: "1h" value: "1h" - entity: sensor category: diagnostic translation_key: time_remaining class: duration dps: - id: 42 type: integer unit: s name: sensor