@@ -0,0 +1,533 @@
|
|
|
+name: MPPT Solar Charge Controller
|
|
|
+products:
|
|
|
+ - id: vf7vdxbt6zd5xyuz
|
|
|
+ manufacturer: Demuda, Bluetti and a lot of others using this hardware
|
|
|
+ model: LM 4048/6048
|
|
|
+entities:
|
|
|
+# energy
|
|
|
+ - entity: sensor
|
|
|
+ name: Cumulative power
|
|
|
+ class: energy
|
|
|
+ dps:
|
|
|
+ - id: 103
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kWh
|
|
|
+ class: total_increasing
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ name: Daily power
|
|
|
+ class: energy
|
|
|
+ dps:
|
|
|
+ - id: 102
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kWh
|
|
|
+ class: total
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: switch
|
|
|
+ name: Switch (unknown)
|
|
|
+ hidden: true
|
|
|
+ dps:
|
|
|
+ - id: 6
|
|
|
+ type: boolean
|
|
|
+ name: switch
|
|
|
+ optional: true
|
|
|
+ - entity: switch
|
|
|
+ name: USB2 (unknown)
|
|
|
+ hidden: true
|
|
|
+ dps:
|
|
|
+ - id: 17
|
|
|
+ type: boolean
|
|
|
+ name: switch
|
|
|
+ optional: true
|
|
|
+ - entity: button
|
|
|
+ name: Self-checking
|
|
|
+ dps:
|
|
|
+ - id: 14
|
|
|
+ type: boolean
|
|
|
+ name: button
|
|
|
+ optional: true
|
|
|
+ - entity: button
|
|
|
+ hidden: true
|
|
|
+ name: Factory-reset (not tested)
|
|
|
+ dps:
|
|
|
+ - id: 16
|
|
|
+ type: boolean
|
|
|
+ name: button
|
|
|
+ optional: true
|
|
|
+ - entity: button
|
|
|
+ name: Refresh
|
|
|
+ dps:
|
|
|
+ - id: 120
|
|
|
+ type: boolean
|
|
|
+ name: button
|
|
|
+ optional: true
|
|
|
+# configuation
|
|
|
+ - entity: button
|
|
|
+ name: Save value
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 109
|
|
|
+ type: boolean
|
|
|
+ name: button
|
|
|
+ optional: true
|
|
|
+ - entity: button
|
|
|
+ name: Read value from device
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 107
|
|
|
+ type: boolean
|
|
|
+ name: button
|
|
|
+ optional: true
|
|
|
+ - entity: switch
|
|
|
+ name: Load (unknown)
|
|
|
+ hidden: true
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 15
|
|
|
+ type: boolean
|
|
|
+ name: switch
|
|
|
+ optional: true
|
|
|
+ - entity: number
|
|
|
+ name: Over-voltage value
|
|
|
+ category: config
|
|
|
+ class: battery
|
|
|
+ dps:
|
|
|
+ - id: 11
|
|
|
+ type: integer
|
|
|
+ optional: true
|
|
|
+ name: value
|
|
|
+ unit: V
|
|
|
+ range:
|
|
|
+ min: 0
|
|
|
+ max: 9999
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: number
|
|
|
+ name: Under-voltage value
|
|
|
+ category: config
|
|
|
+ class: battery
|
|
|
+ dps:
|
|
|
+ - id: 12
|
|
|
+ type: integer
|
|
|
+ optional: true
|
|
|
+ name: value
|
|
|
+ unit: V
|
|
|
+ range:
|
|
|
+ min: 0
|
|
|
+ max: 9999
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: number
|
|
|
+ name: Recovery-voltage value
|
|
|
+ category: config
|
|
|
+ class: battery
|
|
|
+ dps:
|
|
|
+ - id: 110
|
|
|
+ type: integer
|
|
|
+ optional: true
|
|
|
+ name: value
|
|
|
+ unit: V
|
|
|
+ range:
|
|
|
+ min: 0
|
|
|
+ max: 9999
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: select
|
|
|
+ name: Charging method (unknown)
|
|
|
+ hidden: true
|
|
|
+ category: config
|
|
|
+ class: battery
|
|
|
+ dps:
|
|
|
+ - id: 1
|
|
|
+ type: string
|
|
|
+ optional: true
|
|
|
+ name: option
|
|
|
+ mapping:
|
|
|
+ - dps_val: mode_1
|
|
|
+ value: mode 1
|
|
|
+ - dps_val: mode_2
|
|
|
+ value: mode 2
|
|
|
+ - dps_val: mode_3
|
|
|
+ value: mode 3
|
|
|
+ - entity: number
|
|
|
+ name: Load Voltage (unknown)
|
|
|
+ hidden: true
|
|
|
+ category: config
|
|
|
+ class: voltage
|
|
|
+ dps:
|
|
|
+ - id: 3
|
|
|
+ type: integer
|
|
|
+ optional: true
|
|
|
+ name: value
|
|
|
+ unit: V
|
|
|
+ range:
|
|
|
+ min: 0
|
|
|
+ max: 9999
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: number
|
|
|
+ name: Load power (unknown)
|
|
|
+ hidden: true
|
|
|
+ category: config
|
|
|
+ class: power
|
|
|
+ dps:
|
|
|
+ - id: 5
|
|
|
+ type: integer
|
|
|
+ optional: true
|
|
|
+ name: value
|
|
|
+ unit: W
|
|
|
+ range:
|
|
|
+ min: 0
|
|
|
+ max: 10000
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: number
|
|
|
+ name: Load mode (unknown)
|
|
|
+ hidden: true
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 8
|
|
|
+ type: string
|
|
|
+ optional: true
|
|
|
+ name: value
|
|
|
+ range:
|
|
|
+ min: 1
|
|
|
+ max: 9999
|
|
|
+ - entity: select
|
|
|
+ name: Battery voltage
|
|
|
+ category: config
|
|
|
+ class: battery
|
|
|
+ dps:
|
|
|
+ - id: 111
|
|
|
+ type: string
|
|
|
+ optional: true
|
|
|
+ name: option
|
|
|
+ mapping:
|
|
|
+ - dps_val: 12V
|
|
|
+ value: 12V-14.8V
|
|
|
+ - dps_val: 24V
|
|
|
+ value: 24V-29.6V
|
|
|
+ - dps_val: 36V
|
|
|
+ value: 36V-44.4V
|
|
|
+ - dps_val: 48V
|
|
|
+ value: 48V-59.2
|
|
|
+ - dps_val: auto
|
|
|
+ value: auto
|
|
|
+ - entity: select
|
|
|
+ name: Bat type
|
|
|
+ category: config
|
|
|
+ class: battery
|
|
|
+ dps:
|
|
|
+ - id: 112
|
|
|
+ type: string
|
|
|
+ optional: true
|
|
|
+ name: option
|
|
|
+ mapping:
|
|
|
+ - dps_val: USE
|
|
|
+ value: USE
|
|
|
+ - dps_val: FLD
|
|
|
+ value: FLD
|
|
|
+ - dps_val: GEL
|
|
|
+ value: GEL
|
|
|
+ - dps_val: SLD
|
|
|
+ value: SLD
|
|
|
+ - dps_val: Li
|
|
|
+ value: Li
|
|
|
+ - entity: number
|
|
|
+ name: Load Mode
|
|
|
+ category: config
|
|
|
+ mode: box
|
|
|
+ dps:
|
|
|
+ - id: 113
|
|
|
+ type: integer
|
|
|
+ optional: true
|
|
|
+ name: value
|
|
|
+ unit: H
|
|
|
+ range:
|
|
|
+ min: 0
|
|
|
+ max: 24
|
|
|
+ - entity: number
|
|
|
+ name: Charging power
|
|
|
+ category: config
|
|
|
+ mode: box
|
|
|
+ class: battery
|
|
|
+ dps:
|
|
|
+ - id: 114
|
|
|
+ type: integer
|
|
|
+ optional: true
|
|
|
+ name: value
|
|
|
+ unit: "%"
|
|
|
+ range:
|
|
|
+ min: 0
|
|
|
+ max: 100
|
|
|
+ - entity: number
|
|
|
+ name: Over-current protection (unknown)
|
|
|
+ hidden: true
|
|
|
+ category: config
|
|
|
+ class: current
|
|
|
+ dps:
|
|
|
+ - id: 13
|
|
|
+ type: integer
|
|
|
+ optional: true
|
|
|
+ name: value
|
|
|
+ unit: V
|
|
|
+ range:
|
|
|
+ min: 1
|
|
|
+ max: 999
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+# Diagnostics
|
|
|
+ - entity: sensor
|
|
|
+ name: BAT power
|
|
|
+ class: power
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 101
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: W
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ name: Device temp
|
|
|
+ class: temperature
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 108
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: C
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 1
|
|
|
+ - entity: sensor
|
|
|
+ name: Photovoltaic voltage (unknown)
|
|
|
+ hidden: true
|
|
|
+ class: voltage
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 2
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: V
|
|
|
+ class: measurement
|
|
|
+ - entity: sensor
|
|
|
+ name: Load current (unknown)
|
|
|
+ hidden: true
|
|
|
+ class: current
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 4
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: A
|
|
|
+ class: measurement
|
|
|
+ - entity: binary_sensor
|
|
|
+ class: problem
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 7
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: 1
|
|
|
+ value: false
|
|
|
+ - dps_val: 64
|
|
|
+ value: false
|
|
|
+ - value: true
|
|
|
+ - id: 7
|
|
|
+ type: bitfield
|
|
|
+ name: fault_code
|
|
|
+ - id: 7
|
|
|
+ type: bitfield
|
|
|
+ name: description
|
|
|
+ mapping:
|
|
|
+ - dps_val: 0
|
|
|
+ value: "No status"
|
|
|
+ - dps_val: 1
|
|
|
+ value: "Standby"
|
|
|
+ - dps_val: 2
|
|
|
+ value: "Bat_over-voltage"
|
|
|
+ - dps_val: 4
|
|
|
+ value: "Bat_under-voltage"
|
|
|
+ - dps_val: 8
|
|
|
+ value: "Pv_over-voltage"
|
|
|
+ - dps_val: 16
|
|
|
+ value: "Load_short-circuit"
|
|
|
+ - dps_val: 32
|
|
|
+ value: "Load_over-voltage"
|
|
|
+ - dps_val: 64
|
|
|
+ value: "Charging"
|
|
|
+ - dps_val: 128
|
|
|
+ value: "Discharging"
|
|
|
+ - entity: sensor
|
|
|
+ name: Total runing-time (unknown)
|
|
|
+ hidden: true
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: string
|
|
|
+ name: sensor
|
|
|
+ unit: H
|
|
|
+ - entity: sensor
|
|
|
+ name: Total power (unknown)
|
|
|
+ hidden: true
|
|
|
+ class: energy
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 10
|
|
|
+ type: string
|
|
|
+ name: sensor
|
|
|
+ unit: kWh
|
|
|
+ class: total
|
|
|
+ mapping:
|
|
|
+ - scale: 2
|
|
|
+ - entity: sensor
|
|
|
+ name: Controller model
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 118
|
|
|
+ type: string
|
|
|
+ name: sensor
|
|
|
+ - entity: sensor
|
|
|
+ name: MAC address
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 119
|
|
|
+ type: string
|
|
|
+ name: sensor
|
|
|
+# base64 Diagnostic
|
|
|
+ - entity: sensor
|
|
|
+ name: PV voltage
|
|
|
+ class: voltage
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 104
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ unit: V
|
|
|
+ optional: true
|
|
|
+ force: true
|
|
|
+ class: measurement
|
|
|
+ mask: "FFFF00000000"
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ name: PV current
|
|
|
+ class: current
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 104
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ unit: A
|
|
|
+ optional: true
|
|
|
+ class: measurement
|
|
|
+ mask: "0000FFFF0000"
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ name: PV power
|
|
|
+ class: power
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 104
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ unit: W
|
|
|
+ optional: true
|
|
|
+ class: measurement
|
|
|
+ mask: "00000000FFFF"
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ name: BAT voltage
|
|
|
+ class: voltage
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 105
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ unit: V
|
|
|
+ optional: true
|
|
|
+ force: true
|
|
|
+ class: measurement
|
|
|
+ mask: "FFFF00000000"
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ name: Bat current
|
|
|
+ class: current
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 105
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ unit: A
|
|
|
+ optional: true
|
|
|
+ class: measurement
|
|
|
+ mask: "0000FFFF0000"
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ name: Battery charge %
|
|
|
+ class: battery
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 105
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ unit: "%"
|
|
|
+ optional: true
|
|
|
+ class: measurement
|
|
|
+ mask: "00000000FFFF"
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ name: Load voltage
|
|
|
+ class: voltage
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 106
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ unit: V
|
|
|
+ optional: true
|
|
|
+ force: true
|
|
|
+ class: measurement
|
|
|
+ mask: "FFFF00000000"
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ name: Load current
|
|
|
+ class: current
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 106
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ unit: A
|
|
|
+ optional: true
|
|
|
+ class: measurement
|
|
|
+ mask: "0000FFFF0000"
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ name: Load power
|
|
|
+ class: power
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 106
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ unit: W
|
|
|
+ optional: true
|
|
|
+ class: measurement
|
|
|
+ mask: "00000000FFFF"
|
|
|
+ mapping:
|
|
|
+ - scale: 0.1
|