feat (devices): add VT-14N1 air quality monitor
- device is sold in 9-in-1, 14-in-1 and 15-in-1 variants (tuya portal
info says 9-in-1, 12-in-1, 14-in-1). Difference is the 15 and 14 in
1 have time and date (does not seem exposed to Tuya, if the config
is common as seems to be the case from the portal info), and the
14-in-1 (12-in-1?) is missing the CO sensor.
- Works with pth9bw_airquality config, but that is missing the CO
sensor, and has an alarm ringtone config that does not apply to this
device.