@@ -0,0 +1,322 @@
|
|
|
+name: SmartMCB SMT006-8 energy meter
|
|
|
+products:
|
|
|
+ - id: 3xhdofmeo6lgpvd5
|
|
|
+ - id: i5mqmxkho1vahdt2
|
|
|
+primary_entity:
|
|
|
+ entity: switch
|
|
|
+ icon: "mdi:fuse"
|
|
|
+ name: Breaker
|
|
|
+ dps:
|
|
|
+ - id: 16
|
|
|
+ type: boolean
|
|
|
+ name: switch
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: fault_code
|
|
|
+ - id: 19
|
|
|
+ type: string
|
|
|
+ name: breaker_number
|
|
|
+ optional: true
|
|
|
+secondary_entities:
|
|
|
+ - entity: sensor
|
|
|
+ name: Energy
|
|
|
+ class: energy
|
|
|
+ dps:
|
|
|
+ - id: 1
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ class: total_increasing
|
|
|
+ unit: kWh
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Short circuit
|
|
|
+ class: problem
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - value: false
|
|
|
+ - dps_val: 1
|
|
|
+ value: true
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Surge
|
|
|
+ class: problem
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - value: false
|
|
|
+ - dps_val: 2
|
|
|
+ value: true
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Overload
|
|
|
+ class: problem
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - value: false
|
|
|
+ - dps_val: 4
|
|
|
+ value: true
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Leakage current
|
|
|
+ class: safety
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - value: false
|
|
|
+ - dps_val: 8
|
|
|
+ value: true
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: High temperature
|
|
|
+ class: heat
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - value: false
|
|
|
+ - dps_val: 16
|
|
|
+ value: True
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Fire
|
|
|
+ class: smoke
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - value: false
|
|
|
+ - dps_val: 32
|
|
|
+ value: true
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: High power
|
|
|
+ class: power
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - value: false
|
|
|
+ - dps_val: 64
|
|
|
+ value: true
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Self test
|
|
|
+ class: problem
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - value: false
|
|
|
+ - dps_val: 128
|
|
|
+ value: true
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Overcurrent
|
|
|
+ class: problem
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - value: false
|
|
|
+ - dps_val: 256
|
|
|
+ value: true
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Unbalanced
|
|
|
+ class: problem
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - value: false
|
|
|
+ - dps_val: 512
|
|
|
+ value: true
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Overvoltage
|
|
|
+ class: problem
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - value: false
|
|
|
+ - dps_val: 1024
|
|
|
+ value: true
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Undervoltage
|
|
|
+ class: problem
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - value: false
|
|
|
+ - dps_val: 2048
|
|
|
+ value: true
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Phase fault
|
|
|
+ class: problem
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - value: false
|
|
|
+ - dps_val: 4096
|
|
|
+ value: true
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Outage
|
|
|
+ class: power
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - value: true
|
|
|
+ - dps_val: 8192
|
|
|
+ value: false
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Magnetism
|
|
|
+ class: problem
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - value: false
|
|
|
+ - dps_val: 16384
|
|
|
+ value: true
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Low credit
|
|
|
+ class: battery
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - value: false
|
|
|
+ - dps_val: 32768
|
|
|
+ value: true
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Credit
|
|
|
+ class: plug
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - value: true
|
|
|
+ - dps_val: 65536
|
|
|
+ value: false
|
|
|
+ - entity: switch
|
|
|
+ name: Prepay
|
|
|
+ category: config
|
|
|
+ icon: "mdi:hand-coin"
|
|
|
+ dps:
|
|
|
+ - id: 11
|
|
|
+ type: boolean
|
|
|
+ name: switch
|
|
|
+ - entity: button
|
|
|
+ name: Energy reset
|
|
|
+ category: config
|
|
|
+ class: restart
|
|
|
+ dps:
|
|
|
+ - id: 12
|
|
|
+ type: boolean
|
|
|
+ name: button
|
|
|
+ - entity: sensor
|
|
|
+ name: Balance energy
|
|
|
+ category: diagnostic
|
|
|
+ icon: "mdi:home-lightning-bolt"
|
|
|
+ dps:
|
|
|
+ - id: 13
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kWh
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: sensor
|
|
|
+ name: Voltage A
|
|
|
+ class: voltage
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 6
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: V
|
|
|
+ mapping:
|
|
|
+ - mask: "FFFF000000000000"
|
|
|
+ scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ name: Current A
|
|
|
+ class: current
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 6
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: A
|
|
|
+ mapping:
|
|
|
+ - mask: "0000FFFFFF000000"
|
|
|
+ scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ name: Power A
|
|
|
+ class: power
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 6
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: kW
|
|
|
+ mapping:
|
|
|
+ - mask: "0000000000FFFFFF"
|
|
|
+ scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ name: Temperature
|
|
|
+ class: temperature
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 103
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: C
|
|
|
+ class: measurement
|
|
|
+ - entity: sensor
|
|
|
+ name: Leakage current
|
|
|
+ class: current
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 15
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: mA
|
|
|
+ class: measurement
|
|
|
+ optional: true
|