@@ -0,0 +1,226 @@
+name: Moes thermostat WHT-009
+products:
+  - id: 14bmxdarlb4ravgd
+    name: Moes thermostat WHT-009
+primary_entity:
+  entity: climate
+  dps:
+    - id: 1
+      name: hvac_mode
+      type: boolean
+      mapping:
+        - dps_val: false
+          value: "off"
+        - dps_val: true
+          value: heat
+    - id: 2
+      name: preset_mode
+      type: string
+      mapping:
+        - dps_val: manual
+          value: Manual
+        - dps_val: auto
+          value: Auto
+    - id: 16
+      name: temperature
+      type: integer
+      unit: C
+      range:
+        min: 50
+        max: 450
+      mapping:
+        - scale: 10
+          step: 5
+    - id: 24
+      name: current_temperature
+      type: integer
+      mapping:
+        - scale: 10
+          step: 5
+    - id: 19
+      type: integer
+      name: max_temperature
+      mapping:
+        - scale: 10
+    - id: 26
+      type: integer
+      name: min_temperature
+      mapping:
+        - scale: 10
+    - id: 36
+      type: string
+      name: hvac_action
+      mapping:
+        - dps_val: open
+          value: heating
+        - dps_val: close
+          value: idle
+    - id: 71
+      type: string
+      optional: true
+      name: week_program
+
+secondary_entities:
+  - entity: number
+    name: Maximum temperature
+    class: temperature
+    category: config
+    icon: "mdi:thermometer-chevron-up"
+    dps:
+      - id: 19
+        type: integer
+        name: value
+        optional: true
+        unit: C
+        range:
+          min: 150
+          max: 450
+        mapping:
+          - scale: 10
+            step: 10
+  - entity: sensor
+    name: Current temperature
+    class: temperature
+    dps:
+      - id: 24
+        type: integer
+        name: sensor
+        class: measurement
+        unit: C
+        mapping:
+          - scale: 10
+            step: 5
+  - entity: number
+    name: Minimum temperature
+    class: temperature
+    category: config
+    icon: "mdi:thermometer-chevron-down"
+    dps:
+      - id: 26
+        type: integer
+        name: value
+        optional: true
+        unit: C
+        range:
+          min: 50
+          max: 150
+        mapping:
+          - scale: 10
+            step: 10
+  - entity: number
+    name: Temperature correction
+    category: config
+    icon: "mdi:thermometer-check"
+    dps:
+      - id: 27
+        type: integer
+        optional: true
+        name: value
+        range:
+          min: -9
+          max: 9
+  - entity: sensor
+    name: Hvac action
+    dps:
+      - id: 36
+        type: string
+        name: sensor
+  - entity: lock
+    translation_key: child_lock
+    category: config
+    dps:
+      - id: 40
+        type: boolean
+        name: lock
+  - entity: sensor
+    name: External temperature
+    class: temperature
+    dps:
+      - id: 101
+        type: integer
+        name: sensor
+        class: measurement
+        unit: C
+        mapping:
+          - scale: 10
+            step: 5
+  - entity: select
+    name: Temperature sensor type
+    icon: "mdi:home-thermometer"
+    category: config
+    dps:
+      - id: 102
+        type: string
+        optional: true
+        name: option
+        mapping:
+          - dps_val: IN
+            value: Internal
+          - dps_val: OU
+            value: External
+          - dps_val: AL
+            value: Both
+  - entity: number
+    name: Temperature hysteresis
+    category: config
+    icon: "mdi:thermometer-plus"
+    dps:
+      - id: 103
+        type: integer
+        optional: true
+        name: value
+        unit: °
+        range:
+          min: 1
+          max: 5
+  - entity: number
+    name: High protection temperature setting
+    class: temperature
+    category: config
+    icon: "mdi:thermometer-chevron-up"
+    dps:
+      - id: 104
+        type: integer
+        name: value
+        optional: true
+        unit: C
+        range:
+          min: 100
+          max: 700
+        mapping:
+          - scale: 10
+            step: 10
+  - entity: number
+    name: Low protection temperature setting
+    class: temperature
+    category: config
+    icon: "mdi:thermometer-chevron-down"
+    dps:
+      - id: 105
+        type: integer
+        name: value
+        optional: true
+        unit: C
+        range:
+          min: 0
+          max: 100
+        mapping:
+          - scale: 10
+            step: 10
+  - entity: number
+    name: Eco mode temperature setting
+    class: temperature
+    category: config
+    icon: "mdi:leaf"
+    dps:
+      - id: 106
+        type: integer
+        name: value
+        optional: true
+        unit: C
+        range:
+          min: 0
+          max: 300
+        mapping:
+          - scale: 10
+            step: 10