@@ -0,0 +1,64 @@
+name: Ferroli Titano Twin
+products:
+ - id: lci0ebsz7ftaruaf
+ name: DT EWH
+primary_entity:
+ entity: climate
+ dps:
+ - id: 1
+ name: hvac_mode
+ type: boolean
+ mapping:
+ - dps_val: false
+ value: "off"
+ - dps_val: true
+ constraint: preset_mode
+ conditions:
+ - dps_val: manual
+ value: heat_cool
+ - dps_val: eco
+ value: heat
+ - id: 2
+ name: preset_mode
+ type: string
+ value: "eco"
+ - id: 4
+ name: disinfection
+ value: "on"
+ - id: 9
+ type: integer
+ name: temperature
+ range:
+ min: 40
+ max: 80
+ - step: 5
+ unit: C
+ step: 5
+ - id: 10
+ name: current_temperature
+ - id: 101
+ name: fault_code
+ - id: 102
+ name: workstate
+ - id: 103
+ name: antifreeze
+ - id: 104
+ name: target_temperature