@@ -0,0 +1,153 @@
|
|
|
+name: Tuya Wifi Energy Consumption Meter
|
|
|
+products:
|
|
|
+ - id: 79a7z01v3n35kytb
|
|
|
+ name: V-WIFI-DL02-ES
|
|
|
+primary_entity:
|
|
|
+ entity: sensor
|
|
|
+ category: diagnostic
|
|
|
+ name: Total Energy
|
|
|
+ class: energy
|
|
|
+ dps:
|
|
|
+ - id: 123
|
|
|
+ name: sensor
|
|
|
+ type: integer
|
|
|
+ unit: kWh
|
|
|
+ class: total_increasing
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - id: 103
|
|
|
+ name: Device State
|
|
|
+ type: string
|
|
|
+ mapping:
|
|
|
+ - dps_val: close
|
|
|
+ value: close
|
|
|
+ default: true
|
|
|
+ - dps_val: monitor
|
|
|
+ value: monitor
|
|
|
+ - dps_val: working
|
|
|
+ value: working
|
|
|
+ - dps_val: warning
|
|
|
+ value: warning
|
|
|
+secondary_entities:
|
|
|
+ - entity: sensor
|
|
|
+ name: Power A
|
|
|
+ category: diagnostic
|
|
|
+ class: power
|
|
|
+ dps:
|
|
|
+ - id: 105
|
|
|
+ name: sensor
|
|
|
+ type: integer
|
|
|
+ unit: W
|
|
|
+ force: true
|
|
|
+ class: measurement
|
|
|
+ - entity: sensor
|
|
|
+ name: Current A
|
|
|
+ category: diagnostic
|
|
|
+ class: current
|
|
|
+ dps:
|
|
|
+ - id: 106
|
|
|
+ name: sensor
|
|
|
+ type: integer
|
|
|
+ unit: A
|
|
|
+ class: measurement
|
|
|
+ force: true
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ name: Voltage A
|
|
|
+ category: diagnostic
|
|
|
+ class: voltage
|
|
|
+ dps:
|
|
|
+ - id: 107
|
|
|
+ name: sensor
|
|
|
+ type: integer
|
|
|
+ unit: V
|
|
|
+ class: measurement
|
|
|
+ force: true
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ category: diagnostic
|
|
|
+ name: Total Energy A
|
|
|
+ class: energy
|
|
|
+ dps:
|
|
|
+ - id: 108
|
|
|
+ name: sensor
|
|
|
+ type: integer
|
|
|
+ unit: kWh
|
|
|
+ class: total_increasing
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ category: diagnostic
|
|
|
+ name: Today Energy A
|
|
|
+ class: energy
|
|
|
+ dps:
|
|
|
+ - id: 109
|
|
|
+ name: sensor
|
|
|
+ type: integer
|
|
|
+ unit: kWh
|
|
|
+ class: total_increasing
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ name: Power B
|
|
|
+ category: diagnostic
|
|
|
+ class: power
|
|
|
+ dps:
|
|
|
+ - id: 115
|
|
|
+ name: sensor
|
|
|
+ type: integer
|
|
|
+ unit: W
|
|
|
+ force: true
|
|
|
+ class: measurement
|
|
|
+ - entity: sensor
|
|
|
+ name: Current B
|
|
|
+ category: diagnostic
|
|
|
+ class: current
|
|
|
+ dps:
|
|
|
+ - id: 116
|
|
|
+ name: sensor
|
|
|
+ type: integer
|
|
|
+ unit: A
|
|
|
+ class: measurement
|
|
|
+ force: true
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ name: Voltage B
|
|
|
+ category: diagnostic
|
|
|
+ class: voltage
|
|
|
+ dps:
|
|
|
+ - id: 117
|
|
|
+ name: sensor
|
|
|
+ type: integer
|
|
|
+ unit: V
|
|
|
+ class: measurement
|
|
|
+ force: true
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ category: diagnostic
|
|
|
+ name: Total Energy B
|
|
|
+ class: energy
|
|
|
+ dps:
|
|
|
+ - id: 118
|
|
|
+ name: sensor
|
|
|
+ type: integer
|
|
|
+ unit: kWh
|
|
|
+ class: total_increasing
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ category: diagnostic
|
|
|
+ name: Today Energy B
|
|
|
+ class: energy
|
|
|
+ dps:
|
|
|
+ - id: 119
|
|
|
+ name: sensor
|
|
|
+ type: integer
|
|
|
+ unit: kWh
|
|
|
+ class: total_increasing
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|