fix (smartplug_usb): disable energy sensor by default and make optional

Other sensors are optional, but energy sensor (which is the least reliable
in general) was not. This should be hidden by default, as even when present
the add_ele (dp 17) sensors on Tuya smartplugs are not generally usable as
energy sensors.
Jason Rumney 1 tháng trước cách đây
mục cha
commit
c42be5fe62
1 tập tin đã thay đổi với 2 bổ sung0 xóa
  1. 2 0
      custom_components/tuya_local/devices/smartplug_usb.yaml

+ 2 - 0
custom_components/tuya_local/devices/smartplug_usb.yaml

@@ -103,9 +103,11 @@ entities:
   - entity: sensor
     class: energy
     category: diagnostic
+    hidden: true
     dps:
       - id: 17
         type: integer
+        optional: true
         name: sensor
         unit: kWh
         class: total_increasing