@@ -0,0 +1,161 @@
|
|
|
+name: Energy recovery ventilator
|
|
|
+
|
|
|
+products:
|
|
|
+ - id: jqjrmutjj0zfhjzr
|
|
|
+ manufacturer: Pioneer
|
|
|
+ model: ECOasis 150
|
|
|
+
|
|
|
+entities:
|
|
|
+ #################################################################
|
|
|
+ # Controls
|
|
|
+ #################################################################
|
|
|
+
|
|
|
+ - entity: fan
|
|
|
+ translation_only_key: fan_with_presets
|
|
|
+ dps:
|
|
|
+ - id: 1
|
|
|
+ type: boolean
|
|
|
+ name: switch
|
|
|
+
|
|
|
+ - id: 2
|
|
|
+ type: string
|
|
|
+ name: preset_mode
|
|
|
+ mapping:
|
|
|
+ # Device firmware reports the truncated value "manua" (confirmed
|
|
|
+ # from the raw Tuya IoT portal JSON), not "manual".
|
|
|
+ - dps_val: manua
|
|
|
+ value: manual
|
|
|
+ - dps_val: auto
|
|
|
+ value: auto
|
|
|
+ - dps_val: sleep
|
|
|
+ value: sleep
|
|
|
+ - dps_val: "4"
|
|
|
+ value: low
|
|
|
+ - dps_val: "5"
|
|
|
+ value: medium
|
|
|
+ - dps_val: "6"
|
|
|
+ value: high
|
|
|
+
|
|
|
+ - entity: fan
|
|
|
+ name: Supply
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 101
|
|
|
+ type: integer
|
|
|
+ name: speed
|
|
|
+ range:
|
|
|
+ min: 0
|
|
|
+ max: 8
|
|
|
+ - id: 1
|
|
|
+ type: boolean
|
|
|
+ name: power
|
|
|
+ - id: 2
|
|
|
+ type: string
|
|
|
+ name: available
|
|
|
+ mapping:
|
|
|
+ - dps_val: manua
|
|
|
+ value_redirect: power
|
|
|
+ - value: false
|
|
|
+
|
|
|
+ - entity: fan
|
|
|
+ name: Exhaust
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 102
|
|
|
+ type: integer
|
|
|
+ name: speed
|
|
|
+ range:
|
|
|
+ min: 0
|
|
|
+ max: 8
|
|
|
+ - id: 1
|
|
|
+ type: boolean
|
|
|
+ name: power
|
|
|
+ - id: 2
|
|
|
+ type: string
|
|
|
+ name: available
|
|
|
+ mapping:
|
|
|
+ - dps_val: manua
|
|
|
+ value_redirect: power
|
|
|
+ - value: false
|
|
|
+
|
|
|
+ #################################################################
|
|
|
+ # Sensors
|
|
|
+ #################################################################
|
|
|
+
|
|
|
+ - entity: sensor
|
|
|
+ class: pm25
|
|
|
+ dps:
|
|
|
+ - id: 3
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: "µg/m³"
|
|
|
+ class: measurement
|
|
|
+
|
|
|
+ - entity: sensor
|
|
|
+ class: carbon_dioxide
|
|
|
+ dps:
|
|
|
+ - id: 6
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: ppm
|
|
|
+ class: measurement
|
|
|
+
|
|
|
+ - entity: sensor
|
|
|
+ class: volatile_organic_compounds_parts
|
|
|
+ dps:
|
|
|
+ - id: 7
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: ppb
|
|
|
+ class: measurement
|
|
|
+
|
|
|
+ - entity: sensor
|
|
|
+ class: humidity
|
|
|
+ dps:
|
|
|
+ - id: 8
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: "%"
|
|
|
+ class: measurement
|
|
|
+
|
|
|
+ - entity: sensor
|
|
|
+ class: temperature
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: F
|
|
|
+ class: measurement
|
|
|
+
|
|
|
+ #################################################################
|
|
|
+ # Diagnostics: filter and fault state
|
|
|
+ #################################################################
|
|
|
+
|
|
|
+ - entity: button
|
|
|
+ translation_key: filter_reset
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 13
|
|
|
+ type: boolean
|
|
|
+ name: button
|
|
|
+ # Filter status codes 0-3 are undocumented; exposed as a raw
|
|
|
+ # attribute rather than an entity until their meaning is known.
|
|
|
+ - id: 105
|
|
|
+ type: string
|
|
|
+ name: filter_status
|
|
|
+
|
|
|
+ - entity: binary_sensor
|
|
|
+ class: problem
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 18
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: 0
|
|
|
+ value: false
|
|
|
+ - value: true
|
|
|
+ # Retain the raw fault bitmap for diagnostics.
|
|
|
+ - id: 18
|
|
|
+ type: bitfield
|
|
|
+ name: fault_code
|