@@ -0,0 +1,245 @@
|
|
|
+name: Portable EV charger
|
|
|
+products:
|
|
|
+ - id: ypdfdnwauasb8rje
|
|
|
+ manufacturer: Vevor
|
|
|
+ model: SS EU Mode2 3.7kW
|
|
|
+entities:
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: status
|
|
|
+ class: enum
|
|
|
+ icon: "mdi:ev-station"
|
|
|
+ dps:
|
|
|
+ - id: 3
|
|
|
+ type: string
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: charger_free
|
|
|
+ value: available
|
|
|
+ - dps_val: charger_insert
|
|
|
+ value: plugged_in
|
|
|
+ - dps_val: charger_free_fault
|
|
|
+ value: fault_unplugged
|
|
|
+ - dps_val: charger_wait
|
|
|
+ value: waiting
|
|
|
+ - dps_val: charger_charging
|
|
|
+ value: charging
|
|
|
+ - dps_val: charger_pause
|
|
|
+ value: paused
|
|
|
+ - dps_val: charger_end
|
|
|
+ value: charged
|
|
|
+ - dps_val: charger_fault
|
|
|
+ value: fault
|
|
|
+ - id: 23
|
|
|
+ type: string
|
|
|
+ name: system_version
|
|
|
+ - id: 33
|
|
|
+ type: string
|
|
|
+ optional: true
|
|
|
+ name: mode_set
|
|
|
+ - entity: sensor
|
|
|
+ class: energy
|
|
|
+ dps:
|
|
|
+ - id: 1
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kWh
|
|
|
+ class: total_increasing
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: number
|
|
|
+ name: Charge current
|
|
|
+ category: config
|
|
|
+ class: current
|
|
|
+ dps:
|
|
|
+ - id: 4
|
|
|
+ type: integer
|
|
|
+ name: value
|
|
|
+ unit: A
|
|
|
+ range:
|
|
|
+ min: 6
|
|
|
+ max: 16
|
|
|
+ - entity: sensor
|
|
|
+ name: Single phase power
|
|
|
+ class: power
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 5
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: kW
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ name: Phase A power
|
|
|
+ class: power
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 6
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: kW
|
|
|
+ mask: "0000000000FFFFFF"
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ class: voltage
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 6
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: V
|
|
|
+ mask: "FFFF000000000000"
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ class: current
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 6
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: A
|
|
|
+ mask: "0000FFFFFF000000"
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ class: power
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: kW
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: binary_sensor
|
|
|
+ class: problem
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 10
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: 0
|
|
|
+ value: false
|
|
|
+ - value: true
|
|
|
+ - id: 10
|
|
|
+ type: bitfield
|
|
|
+ name: fault_code
|
|
|
+ - entity: sensor
|
|
|
+ name: Connection state
|
|
|
+ class: enum
|
|
|
+ icon: "mdi:ev-plug-type2"
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 13
|
|
|
+ type: string
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: controlpi_12v
|
|
|
+ value: Standby
|
|
|
+ - dps_val: controlpi_12v_pwn
|
|
|
+ value: Communication initialising
|
|
|
+ - dps_val: controlpi_9v
|
|
|
+ value: Vehicle detected
|
|
|
+ - dps_val: controlpi_9v_pwm
|
|
|
+ value: Vehicle connected
|
|
|
+ - dps_val: controlpi_6v
|
|
|
+ value: Ready to charge
|
|
|
+ - dps_val: controlpi_6v_pwm
|
|
|
+ value: Charging
|
|
|
+ - dps_val: controlpi_error
|
|
|
+ value: Error
|
|
|
+ - entity: select
|
|
|
+ name: Mode
|
|
|
+ icon: "mdi:ev-station"
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 14
|
|
|
+ type: string
|
|
|
+ optional: true
|
|
|
+ name: option
|
|
|
+ mapping:
|
|
|
+ - dps_val: charge_now
|
|
|
+ value: Immediate
|
|
|
+ - dps_val: charge_pct
|
|
|
+ value: Charge to percent
|
|
|
+ - dps_val: charge_energy
|
|
|
+ value: Fixed charge
|
|
|
+ - dps_val: charge_schedule
|
|
|
+ value: Scheduled charge
|
|
|
+ - dps_val: charge_delay
|
|
|
+ value: Delayed charge
|
|
|
+ - entity: button
|
|
|
+ name: Clear energy
|
|
|
+ class: restart
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 16
|
|
|
+ type: boolean
|
|
|
+ optional: true
|
|
|
+ name: button
|
|
|
+ - entity: switch
|
|
|
+ icon: "mdi:power"
|
|
|
+ dps:
|
|
|
+ - id: 18
|
|
|
+ type: boolean
|
|
|
+ name: switch
|
|
|
+ - entity: sensor
|
|
|
+ class: temperature
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 24
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: C
|
|
|
+ class: measurement
|
|
|
+ - entity: sensor
|
|
|
+ name: Last charge
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 25
|
|
|
+ type: integer
|
|
|
+ optional: true
|
|
|
+ name: sensor
|
|
|
+ unit: kWh
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+
|
|
|
+ - entity: switch
|
|
|
+ category: config
|
|
|
+ name: Live updates
|
|
|
+ icon: "mdi:chart-bar"
|
|
|
+ dps:
|
|
|
+ - id: 27
|
|
|
+ type: string
|
|
|
+ name: switch
|
|
|
+ optional: true
|
|
|
+ mapping:
|
|
|
+ - dps_val: online
|
|
|
+ value: true
|
|
|
+ - dps_val: offline
|
|
|
+ value: false
|
|
|
+ - value: false
|
|
|
+ hidden: true
|
|
|
+ - entity: number
|
|
|
+ name: Delay time
|
|
|
+ category: config
|
|
|
+ icon: "mdi:clock"
|
|
|
+ dps:
|
|
|
+ - id: 28
|
|
|
+ type: integer
|
|
|
+ optional: true
|
|
|
+ name: value
|
|
|
+ unit: h
|
|
|
+ range:
|
|
|
+ min: 0
|
|
|
+ max: 12
|