@@ -14,25 +14,24 @@ from homeassistant.components.climate.const import (
|
|
|
SUPPORT_PRESET_MODE,
|
|
|
SUPPORT_TARGET_TEMPERATURE,
|
|
|
)
|
|
|
-from homeassistant.const import STATE_UNAVAILABLE, TEMP_CELSIUS, TEMP_FAHRENHEIT
|
|
|
-from unittest.mock import ANY
|
|
|
+from homeassistant.const import TEMP_CELSIUS, TEMP_FAHRENHEIT
|
|
|
|
|
|
from ..const import SASWELL_T29UTK_THERMOSTAT_PAYLOAD
|
|
|
from ..helpers import assert_device_properties_set
|
|
|
from .base_device_tests import TuyaDeviceTestCase
|
|
|
|
|
|
POWER_DPS = "1"
|
|
|
-SETTEMP_DPS = "2"
|
|
|
+TEMPERATURE_DPS = "2"
|
|
|
CURRENTTEMP_DPS = "3"
|
|
|
-HVACACTION_DPS = "4"
|
|
|
+HVACMODE_DPS = "4"
|
|
|
FAN_DPS = "5"
|
|
|
UNITS_DPS = "19"
|
|
|
AWAY_DPS = "101"
|
|
|
PROGRAM_DPS = "102"
|
|
|
-HVACMODE_DPS = "103"
|
|
|
+HVACACTION_DPS = "103"
|
|
|
UNKNOWN112_DPS = "112"
|
|
|
UNKNOWN113_DPS = "113"
|
|
|
-TEMPERATURE_DPS = "114"
|
|
|
+TEMPC_DPS = "114"
|
|
|
CURTEMPC_DPS = "115"
|
|
|
TEMPF_DPS = "116"
|
|
|
CURTEMPF_DPS = "117"
|
|
|
@@ -55,15 +54,12 @@ class TestSaswellT29UTKThermostat(TuyaDeviceTestCase):
|
|
|
|
|
|
def test_icon(self):
|
|
|
self.dps[POWER_DPS] = True
|
|
|
- self.dps[HVACACTION_DPS] = "cold"
|
|
|
+ self.dps[HVACMODE_DPS] = "cold"
|
|
|
self.assertEqual(self.subject.icon, "mdi:thermometer-minus")
|
|
|
|
|
|
- self.dps[HVACACTION_DPS] = "hot"
|
|
|
+ self.dps[HVACMODE_DPS] = "hot"
|
|
|
self.assertEqual(self.subject.icon, "mdi:thermometer-plus")
|
|
|
|
|
|
- self.dps[HVACACTION_DPS] = "off"
|
|
|
- self.assertEqual(self.subject.icon, "mdi:thermometer")
|
|
|
-
|
|
|
self.dps[POWER_DPS] = False
|
|
|
self.assertEqual(self.subject.icon, "mdi:thermometer-off")
|
|
|
|
|
|
@@ -76,13 +72,15 @@ class TestSaswellT29UTKThermostat(TuyaDeviceTestCase):
|
|
|
|
|
|
def test_target_temperature(self):
|
|
|
self.dps[UNITS_DPS] = "C"
|
|
|
- self.dps[TEMPERATURE_DPS] = 25
|
|
|
- self.dps[TEMPF_DPS] = 75
|
|
|
+ self.dps[TEMPERATURE_DPS] = 250
|
|
|
self.assertEqual(self.subject.target_temperature, 25)
|
|
|
self.dps[UNITS_DPS] = "F"
|
|
|
+ self.dps[TEMPERATURE_DPS] = 750
|
|
|
self.assertEqual(self.subject.target_temperature, 75)
|
|
|
|
|
|
def test_target_temperature_step(self):
|
|
|
+ self.assertEqual(self.subject.target_temperature_step, 0.5)
|
|
|
+ self.dps[UNITS_DPS] = "F"
|
|
|
self.assertEqual(self.subject.target_temperature_step, 1)
|
|
|
|
|
|
def test_minimum_target_temperature(self):
|
|
|
@@ -101,7 +99,7 @@ class TestSaswellT29UTKThermostat(TuyaDeviceTestCase):
|
|
|
self.dps[UNITS_DPS] = "C"
|
|
|
async with assert_device_properties_set(
|
|
|
self.subject._device,
|
|
|
- {TEMPERATURE_DPS: 24},
|
|
|
+ {TEMPERATURE_DPS: 240},
|
|
|
):
|
|
|
await self.subject.async_set_target_temperature(24)
|
|
|
|
|
|
@@ -109,15 +107,15 @@ class TestSaswellT29UTKThermostat(TuyaDeviceTestCase):
|
|
|
self.dps[UNITS_DPS] = "F"
|
|
|
async with assert_device_properties_set(
|
|
|
self.subject._device,
|
|
|
- {TEMPF_DPS: 74},
|
|
|
+ {TEMPERATURE_DPS: 740},
|
|
|
):
|
|
|
await self.subject.async_set_target_temperature(74)
|
|
|
|
|
|
async def test_set_target_temperature_fails_outside_valid_range(self):
|
|
|
with self.assertRaisesRegex(
|
|
|
- ValueError, "temperature \\(4\\) must be between 5 and 35"
|
|
|
+ ValueError, "temperature \\(4.5\\) must be between 5.0 and 35.0"
|
|
|
):
|
|
|
- await self.subject.async_set_target_temperature(4)
|
|
|
+ await self.subject.async_set_target_temperature(4.5)
|
|
|
|
|
|
def test_current_temperature(self):
|
|
|
self.dps[CURRENTTEMP_DPS] = 250
|
|
|
@@ -142,7 +140,7 @@ class TestSaswellT29UTKThermostat(TuyaDeviceTestCase):
|
|
|
|
|
|
async def test_turn_off(self):
|
|
|
async with assert_device_properties_set(
|
|
|
- self.subject._device, {POWER_DPS: False, HVACMODE_DPS: ANY}
|
|
|
+ self.subject._device, {POWER_DPS: False, HVACMODE_DPS: "off"}
|
|
|
):
|
|
|
await self.subject.async_set_hvac_mode(HVAC_MODE_OFF)
|
|
|
|
|
|
@@ -165,8 +163,6 @@ class TestSaswellT29UTKThermostat(TuyaDeviceTestCase):
|
|
|
|
|
|
self.dps[HVACACTION_DPS] = "hot"
|
|
|
self.assertEqual(self.subject.hvac_action, CURRENT_HVAC_HEAT)
|
|
|
- self.dps[HVACACTION_DPS] = "off"
|
|
|
- self.assertEqual(self.subject.hvac_action, CURRENT_HVAC_IDLE)
|
|
|
|
|
|
self.dps[POWER_DPS] = False
|
|
|
self.assertEqual(self.subject.hvac_action, CURRENT_HVAC_OFF)
|
|
|
@@ -233,9 +229,9 @@ class TestSaswellT29UTKThermostat(TuyaDeviceTestCase):
|
|
|
await self.subject.async_set_preset_mode("Program")
|
|
|
|
|
|
def test_device_state_attributes(self):
|
|
|
- self.dps[SETTEMP_DPS] = 2
|
|
|
self.dps[UNKNOWN112_DPS] = "unknown112"
|
|
|
self.dps[UNKNOWN113_DPS] = 113
|
|
|
+ self.dps[TEMPC_DPS] = 114
|
|
|
self.dps[CURTEMPC_DPS] = 115
|
|
|
self.dps[TEMPF_DPS] = 116
|
|
|
self.dps[CURTEMPF_DPS] = 117
|
|
|
@@ -243,9 +239,9 @@ class TestSaswellT29UTKThermostat(TuyaDeviceTestCase):
|
|
|
self.assertDictEqual(
|
|
|
self.subject.device_state_attributes,
|
|
|
{
|
|
|
- "set_temperature": 0.2,
|
|
|
"unknown_112": "unknown112",
|
|
|
"unknown_113": 113,
|
|
|
+ "temperature_c": 114,
|
|
|
"current_temperature_c": 115,
|
|
|
"temperature_f": 116,
|
|
|
"current_temperature_f": 117,
|