فهرست منبع

fix (morento_mr5866_air_purifier): make the config match the log

Issue #4682

Needed to make dp 11 optional. Also added optional dp 19 (time remaining), which
only seems to be reported when the timer is running.
Jason Rumney 14 ساعت پیش
والد
کامیت
8a97683121
1فایلهای تغییر یافته به همراه12 افزوده شده و 0 حذف شده
  1. 12 0
      custom_components/tuya_local/devices/morento_mr5866_air_purifier.yaml

+ 12 - 0
custom_components/tuya_local/devices/morento_mr5866_air_purifier.yaml

@@ -69,6 +69,7 @@ entities:
     dps:
       - id: 11
         name: button
+        optional: true
         type: boolean
 
   - entity: select
@@ -88,6 +89,17 @@ entities:
           - dps_val: 8h
             value: 8h
 
+  - entity: sensor
+    translation_key: time_remaining
+    class: duration
+    category: diagnostic
+    dps:
+      - id: 19
+        type: integer
+        optional: true
+        name: sensor
+        unit: min
+
   - entity: sensor
     translation_key: air_quality
     class: enum