Add notes in README about partially working devices.

- setting speed on Anko fan is not working.
- setting and anything on Inkbird thermostat is not working.

Based on dps values, speed on Anko heater should be a string, even though it is a number, so stringify it.
Jason Rumney 4 yıl önce
ebeveyn
işleme
8899242870

+ 5 - 0
README.md

@@ -117,12 +117,17 @@ When child lock is enabled, the heater's display will flash with the child lock
 
 When setting the target temperature, different heaters have different behaviour, which you may need to compensate for.  From observation, GPPH heaters allow the temperature to reach 3 degrees higher than the set temperature before turning off, and 1 degree lower before turning on again.  Kogan Heaters on the other hand turn off when the temperature reaches 1 degree over the targetin LOW mode, and turn on again 3 degrees below the target.  To make these heaters act the same in LOW power mode, you need to set the Kogan thermostat 2 degrees higher than the GPPH thermostat.  In HIGH power mode however, they seem to act the same as the GPPH heaters.
 
+The Inkbird thermostat switch does not seem to work for setting anything.  If you can figure out how to make setting temperatures and presets work, please leave feedback in Issue #19.
+
 ## Fan gotchas
 
 Fans should be configured as `fan` entities, with any auxilary functions such as panel lighting control, child locks or additional switches configured as `light`, `lock` or `switch` entities.  Configuration of Goldair fans as `climate` entities is supported for backward compatibility but is deprecated, and may be removed in future.
 
 Reportedly, Goldair fans can be a bit flaky. If they become unresponsive, give them about 60 seconds to wake up again.
 
+Anko fans mostly work, except setting the speed does not seem to work. If you can figure out how to set the speed through the Tuya protocol for these devices, please leave feedback on Issue #22.
+
+
 ## Humidifiers and dehumidifiers
 
 Humidifiers and Dehumidifiers should be configuured as `humidifier` entities, probably with `fan` entities as well if the fan speed can also be controlled, and any other auxilary features such as panel lighting, child locks or additional switches configured as `light`, `lock` or `switch` entities.  Configration of Goldair Dehumidifiers and Eanons Humidifiers as `climate` entities is also supported for backwards compatibility, but is deprecated and may be removed in future.  In particular, when humidifiers are represented as `climate` entities, the running mode will show as `Dry`, as the climate entity only supports functions commonly found on air conditioners/heatpumps.

+ 1 - 0
custom_components/tuya_local/devices/anko_fan.yaml

@@ -17,6 +17,7 @@ primary_entity:
           value: sleep
     - id: 3
       type: integer
+      stringify: true
       name: speed
       range:
         min: 1