@@ -1,31 +1,45 @@
|
|
|
-name: PW040
|
|
|
+name: Water heat pump
|
|
|
products:
|
|
|
- id: 5oc9wmac3bbidekc
|
|
|
manufacturer: Powerworld / Michl
|
|
|
model: PW040 / SMP13
|
|
|
entities:
|
|
|
- - entity: number
|
|
|
- name: WarmwasserSoll_T # hot water target value
|
|
|
- category: config
|
|
|
+ - entity: water_heater
|
|
|
+ translation_key: water_air
|
|
|
dps:
|
|
|
- - id: 123
|
|
|
+ - id: 1
|
|
|
+ type: boolean
|
|
|
+ name: operation_mode
|
|
|
+ mapping:
|
|
|
+ - dps_val: false
|
|
|
+ value: "off"
|
|
|
+ - dps_val: true
|
|
|
+ constraint: work_mode
|
|
|
+ conditions:
|
|
|
+ - dps_val: heat
|
|
|
+ value: heat
|
|
|
+ - dps_val: wth
|
|
|
+ value: hotwater
|
|
|
+ - dps_val: cool
|
|
|
+ value: cool
|
|
|
+ - dps_val: wth_heat
|
|
|
+ value: hotwater_heat
|
|
|
+ - dps_val: wth_cool
|
|
|
+ value: hotwater_cool
|
|
|
+ - id: 5
|
|
|
+ type: string
|
|
|
+ name: work_mode
|
|
|
hidden: true
|
|
|
+ - id: 125
|
|
|
type: integer
|
|
|
- name: value
|
|
|
+ name: temperature
|
|
|
unit: C
|
|
|
range:
|
|
|
- min: 30
|
|
|
+ min: 28
|
|
|
max: 55
|
|
|
- - entity: sensor
|
|
|
- name: Warmwasser_T # hot water (actual value)
|
|
|
- class: temperature
|
|
|
- category: diagnostic
|
|
|
- dps:
|
|
|
- id: 108 # Warmwasser_T (ist): hot water (actual value)
|
|
|
type: integer
|
|
|
- unit: C
|
|
|
- name: sensor
|
|
|
- class: measurement
|
|
|
+ name: current_temperature
|
|
|
- id: 4
|
|
|
hidden: true
|
|
|
type: integer
|
|
|
@@ -34,25 +48,64 @@ entities:
|
|
|
range:
|
|
|
min: 0
|
|
|
max: 9999
|
|
|
- - entity: select
|
|
|
- name: Betrieb # operation
|
|
|
- category: config
|
|
|
+ - entity: climate
|
|
|
dps:
|
|
|
- id: 1
|
|
|
type: boolean
|
|
|
- name: option
|
|
|
+ name: hvac_mode
|
|
|
mapping:
|
|
|
- dps_val: false
|
|
|
- value: "aus" # off
|
|
|
+ value: "off"
|
|
|
+ available: wth_off
|
|
|
- dps_val: true
|
|
|
- value: "aktiv" # active
|
|
|
- - entity: select
|
|
|
- name: Energiemodus # energy mode
|
|
|
- category: config
|
|
|
- dps:
|
|
|
+ constraint: work_mode
|
|
|
+ conditions:
|
|
|
+ - dps_val: heat
|
|
|
+ value: heat
|
|
|
+ available: wth_off
|
|
|
+ - dps_val: cool
|
|
|
+ value: cool
|
|
|
+ available: wth_off
|
|
|
+ - dps_val: wth
|
|
|
+ value: "off"
|
|
|
+ available: wth_on
|
|
|
+ - dps_val: wth_heat
|
|
|
+ value: heat
|
|
|
+ available: wth_on
|
|
|
+ - dps_val: wth_cool
|
|
|
+ value: cool
|
|
|
+ available: wth_on
|
|
|
+ - id: 5
|
|
|
+ type: string
|
|
|
+ name: work_mode
|
|
|
+ hidden: true
|
|
|
+ - id: 5
|
|
|
+ type: string
|
|
|
+ name: wth_on
|
|
|
+ hidden: true
|
|
|
+ mapping:
|
|
|
+ - dps_val: wth
|
|
|
+ value: true
|
|
|
+ - dps_val: wth_heat
|
|
|
+ value: true
|
|
|
+ - dps_val: wth_cool
|
|
|
+ value: true
|
|
|
+ - value: false
|
|
|
+ - id: 5
|
|
|
+ type: string
|
|
|
+ name: wth_off
|
|
|
+ hidden: true
|
|
|
+ mapping:
|
|
|
+ - dps_val: wth
|
|
|
+ value: false
|
|
|
+ - dps_val: wth_heat
|
|
|
+ value: false
|
|
|
+ - dps_val: wth_cool
|
|
|
+ value: false
|
|
|
+ - value: true
|
|
|
- id: 2
|
|
|
type: string
|
|
|
- name: option
|
|
|
+ name: preset_mode
|
|
|
mapping:
|
|
|
- dps_val: smart
|
|
|
value: comfort
|
|
|
@@ -60,50 +113,48 @@ entities:
|
|
|
value: boost
|
|
|
- dps_val: mute
|
|
|
value: eco
|
|
|
- - entity: select
|
|
|
- name: Betriebsart # Operating mode
|
|
|
- category: config
|
|
|
- dps:
|
|
|
- - id: 5
|
|
|
- type: string
|
|
|
- name: option
|
|
|
+ - id: 101
|
|
|
+ type: integer
|
|
|
+ name: current_temperature
|
|
|
+ - id: 123
|
|
|
+ type: integer
|
|
|
+ name: temperature
|
|
|
+ unit: C
|
|
|
+ range:
|
|
|
+ min: 30
|
|
|
+ max: 55
|
|
|
mapping:
|
|
|
- - dps_val: heat
|
|
|
- value: nur Heizen # only heating
|
|
|
- - dps_val: wth # only hot water
|
|
|
- value: nur WW # only hot water
|
|
|
- - dps_val: cool
|
|
|
- value: Kuehlen # cooling
|
|
|
- - dps_val: wth_heat
|
|
|
- value: WW und Heizen # hot water and heating
|
|
|
- - dps_val: wth_cool
|
|
|
- value: WW und Kuehlen # hot water and cooling
|
|
|
+ - constraint: work_mode
|
|
|
+ conditions:
|
|
|
+ - dps_val:
|
|
|
+ - cool
|
|
|
+ - wth_cool
|
|
|
+ value_redirect: cooling_temp
|
|
|
+ range:
|
|
|
+ min: 7
|
|
|
+ max: 30
|
|
|
+ - id: 124
|
|
|
+ hidden: true
|
|
|
+ type: integer
|
|
|
+ unit: C
|
|
|
+ name: cooling_temp
|
|
|
+ range:
|
|
|
+ min: 7
|
|
|
+ max: 30
|
|
|
- entity: select
|
|
|
- name: Heiz-RL-Steuerung # heating return flow control
|
|
|
+ name: Heating return
|
|
|
category: config
|
|
|
dps:
|
|
|
- id: 132
|
|
|
type: string
|
|
|
name: option
|
|
|
mapping:
|
|
|
- - dps_val: 0 # manuelle RLsoll_T - take return flow target value
|
|
|
- value: manuell # boost
|
|
|
- - dps_val: 1 # HeizKennlinie aktiv
|
|
|
- value: Heizkennlinie # eco - characteristic curve
|
|
|
- - entity: sensor
|
|
|
- name: WpRL_T
|
|
|
- class: temperature
|
|
|
- category: diagnostic
|
|
|
- dps:
|
|
|
- - id: 101
|
|
|
- type: integer
|
|
|
- unit: C
|
|
|
- name: sensor
|
|
|
- range:
|
|
|
- min: -30
|
|
|
- max: 99
|
|
|
+ - dps_val: 0
|
|
|
+ value: Manual
|
|
|
+ - dps_val: 1
|
|
|
+ value: Eco
|
|
|
- entity: sensor
|
|
|
- name: WpVL_T # outlet temperature
|
|
|
+ name: Outlet temperature
|
|
|
class: temperature
|
|
|
category: diagnostic
|
|
|
dps:
|
|
|
@@ -111,12 +162,9 @@ entities:
|
|
|
type: integer
|
|
|
unit: C
|
|
|
name: sensor
|
|
|
- range:
|
|
|
- min: -30
|
|
|
- max: 99
|
|
|
- entity: sensor
|
|
|
- name: Umgebung_T # ambient temperature
|
|
|
class: temperature
|
|
|
+ name: Ambient temperature
|
|
|
category: diagnostic
|
|
|
dps:
|
|
|
- id: 103
|
|
|
@@ -124,11 +172,8 @@ entities:
|
|
|
unit: C
|
|
|
name: sensor
|
|
|
class: measurement
|
|
|
- range:
|
|
|
- min: -30
|
|
|
- max: 99
|
|
|
- entity: sensor
|
|
|
- name: GasVL_T # gas outlet temperature
|
|
|
+ name: Gas outlet temperature
|
|
|
class: temperature
|
|
|
category: diagnostic
|
|
|
dps:
|
|
|
@@ -141,7 +186,7 @@ entities:
|
|
|
min: -30
|
|
|
max: 99
|
|
|
- entity: sensor
|
|
|
- name: GasRL_T # gas temperature return flow
|
|
|
+ name: Gas return temperature
|
|
|
class: temperature
|
|
|
category: diagnostic
|
|
|
dps:
|
|
|
@@ -150,11 +195,8 @@ entities:
|
|
|
unit: C
|
|
|
name: sensor
|
|
|
class: measurement
|
|
|
- range:
|
|
|
- min: -30
|
|
|
- max: 99
|
|
|
- entity: sensor
|
|
|
- name: Verdampfer_T # vaporiser temperature
|
|
|
+ name: Vaporiser temperature
|
|
|
class: temperature
|
|
|
category: diagnostic
|
|
|
dps:
|
|
|
@@ -167,7 +209,7 @@ entities:
|
|
|
min: -30
|
|
|
max: 99
|
|
|
- entity: sensor
|
|
|
- name: Kuehlschlangen_T # coil temperature
|
|
|
+ name: Coil temperature
|
|
|
class: temperature
|
|
|
category: diagnostic
|
|
|
dps:
|
|
|
@@ -179,8 +221,8 @@ entities:
|
|
|
range:
|
|
|
min: -30
|
|
|
max: 99
|
|
|
- - entity: sensor # main expansion valve opening level
|
|
|
- name: Ventiloeffnung_HauptExpansion_P
|
|
|
+ - entity: sensor
|
|
|
+ name: EEV opening
|
|
|
category: diagnostic
|
|
|
dps:
|
|
|
- id: 109
|
|
|
@@ -192,7 +234,7 @@ entities:
|
|
|
min: 0
|
|
|
max: 500
|
|
|
- entity: sensor # enthalpy expansion valve opening level
|
|
|
- name: Ventiloeffnung_EnthalpieExpansion_P
|
|
|
+ name: EEV2 opening
|
|
|
category: diagnostic
|
|
|
dps:
|
|
|
- id: 111
|
|
|
@@ -204,7 +246,6 @@ entities:
|
|
|
min: 0
|
|
|
max: 500
|
|
|
- entity: sensor
|
|
|
- name: Kompressor_I # Compressor current
|
|
|
class: current
|
|
|
category: diagnostic
|
|
|
dps:
|
|
|
@@ -217,7 +258,6 @@ entities:
|
|
|
min: 0
|
|
|
max: 65
|
|
|
- entity: sensor
|
|
|
- name: Kompressor_f # Compressor frequency
|
|
|
class: frequency
|
|
|
category: diagnostic
|
|
|
dps:
|
|
|
@@ -230,7 +270,7 @@ entities:
|
|
|
min: -99
|
|
|
max: 150
|
|
|
- entity: sensor
|
|
|
- name: Kuehlkoerper_T # Heat sink temperature
|
|
|
+ name: Heatsink temperature
|
|
|
class: temperature
|
|
|
category: diagnostic
|
|
|
dps:
|
|
|
@@ -243,7 +283,7 @@ entities:
|
|
|
min: -99
|
|
|
max: 150
|
|
|
- entity: sensor
|
|
|
- name: Bus_Udc # bus dc voltage
|
|
|
+ name: DC voltage
|
|
|
class: voltage
|
|
|
category: diagnostic
|
|
|
dps:
|
|
|
@@ -256,7 +296,7 @@ entities:
|
|
|
min: 0
|
|
|
max: 999
|
|
|
- entity: sensor
|
|
|
- name: DcLuefter1_vWind # dc fan 1 speed
|
|
|
+ name: DC fan 1
|
|
|
category: diagnostic
|
|
|
dps:
|
|
|
- id: 116
|
|
|
@@ -268,7 +308,7 @@ entities:
|
|
|
min: 0
|
|
|
max: 1500
|
|
|
- entity: sensor
|
|
|
- name: DcLuefter2_vWind # dc fan 2 speed
|
|
|
+ name: DC fan 2
|
|
|
category: diagnostic
|
|
|
dps:
|
|
|
- id: 15
|
|
|
@@ -280,31 +320,19 @@ entities:
|
|
|
range:
|
|
|
min: 0
|
|
|
max: 1500
|
|
|
- - entity: number # manual heat water temperature
|
|
|
- name: Heizwasser_Tsoll manuell # e_HeizRLsoll_T_ohneKennlinie (einstellbar)
|
|
|
- category: config
|
|
|
- dps:
|
|
|
- - id: 125
|
|
|
- type: integer
|
|
|
- name: value
|
|
|
- unit: C
|
|
|
- range:
|
|
|
- min: 28
|
|
|
- max: 55
|
|
|
- - entity: number # return flow to cool target value (delta temperature)
|
|
|
- name: RLzuKuehlsoll_dT # e_RL_zu_KuehlSoll_dT
|
|
|
+ - entity: number
|
|
|
+ name: Cooling hysteresis
|
|
|
category: config
|
|
|
dps:
|
|
|
- id: 121
|
|
|
- hidden: true
|
|
|
type: integer
|
|
|
name: value
|
|
|
unit: C
|
|
|
range:
|
|
|
min: 2
|
|
|
max: 18
|
|
|
- - entity: number # return flow to return flow target value (delta temp.)
|
|
|
- name: RLzuRLsoll_dT # e_RL_zu_RLsoll_dT
|
|
|
+ - entity: number
|
|
|
+ name: Heating hysteresis
|
|
|
category: config
|
|
|
dps:
|
|
|
- id: 122
|
|
|
@@ -314,21 +342,8 @@ entities:
|
|
|
range:
|
|
|
min: 2
|
|
|
max: 18
|
|
|
- - entity: number # cooling target value (temperature)
|
|
|
- name: Kuehlsoll_T # e_KuehlSoll_T
|
|
|
- class: temperature
|
|
|
- category: config
|
|
|
- dps:
|
|
|
- - id: 124
|
|
|
- hidden: true
|
|
|
- type: integer
|
|
|
- unit: C
|
|
|
- name: value
|
|
|
- range:
|
|
|
- min: 7
|
|
|
- max: 30
|
|
|
- - entity: number # water compensation temperature
|
|
|
- name: WasserAusgleich_T # e_WasserAusgleich_T
|
|
|
+ - entity: number
|
|
|
+ name: Water temperature offset
|
|
|
class: temperature
|
|
|
category: config
|
|
|
dps:
|
|
|
@@ -340,7 +355,7 @@ entities:
|
|
|
min: -5
|
|
|
max: 15
|
|
|
- entity: number # temperature offset of characteristic curve
|
|
|
- name: Kennlinie_Offset_T # ea_Offset_T
|
|
|
+ name: Characteristic curve offset
|
|
|
class: temperature
|
|
|
category: config
|
|
|
dps:
|
|
|
@@ -351,8 +366,8 @@ entities:
|
|
|
range:
|
|
|
min: 0
|
|
|
max: 40
|
|
|
- - entity: number # gradient of characteristic curve
|
|
|
- name: Kennlinie_m_x10 # ea_Steigung_m_x10
|
|
|
+ - entity: number
|
|
|
+ name: Characteristic curve gradient
|
|
|
category: config
|
|
|
dps:
|
|
|
- id: 134
|
|
|
@@ -361,21 +376,20 @@ entities:
|
|
|
range:
|
|
|
min: 1
|
|
|
max: 30
|
|
|
- - entity: select # compressor frequency @ target temperature
|
|
|
- name: Kompressor_f @Zieltemperatur # ea_f_at_ZielTemp_str
|
|
|
+ - entity: select
|
|
|
+ name: Target temperature action
|
|
|
category: config
|
|
|
dps:
|
|
|
- id: 135
|
|
|
type: string
|
|
|
- unit: Hz
|
|
|
name: option
|
|
|
mapping:
|
|
|
- - dps_val: 0
|
|
|
- value: FreqBeibehalten
|
|
|
- - dps_val: 1
|
|
|
- value: FreqReduktion
|
|
|
- - entity: number # pipe heater start temperature
|
|
|
- name: RohrheizungStart_T # ea_RohrheizungStart_T
|
|
|
+ - dps_val: "0"
|
|
|
+ value: Compressor off
|
|
|
+ - dps_val: "1"
|
|
|
+ value: Compressor reduced frequency
|
|
|
+ - entity: number
|
|
|
+ name: Pipe heating start temperature
|
|
|
class: temperature
|
|
|
category: config
|
|
|
dps:
|
|
|
@@ -387,7 +401,7 @@ entities:
|
|
|
min: -20
|
|
|
max: 20
|
|
|
- entity: number
|
|
|
- name: WarmwasserStart_t # hot water start time
|
|
|
+ name: Hot water start temperature
|
|
|
category: config
|
|
|
dps:
|
|
|
- id: 137
|
|
|
@@ -397,8 +411,8 @@ entities:
|
|
|
range:
|
|
|
min: 0
|
|
|
max: 60
|
|
|
- - entity: select # water pump stop config
|
|
|
- name: Modus WP-Wasserpumpe # ea_WasserpumpenStopp_str
|
|
|
+ - entity: select
|
|
|
+ name: Water pump stop mode
|
|
|
category: config
|
|
|
dps:
|
|
|
- id: 138
|
|
|
@@ -406,11 +420,11 @@ entities:
|
|
|
name: option
|
|
|
mapping:
|
|
|
- dps_val: 0
|
|
|
- value: Stopp # stop immediately
|
|
|
+ value: Immediate stop
|
|
|
- dps_val: 1
|
|
|
- value: Nachlauf # stop after trail
|
|
|
+ value: Ramp down
|
|
|
- entity: number # defrost start temperature
|
|
|
- name: Abtau_Tstart # ew_AbtauenStart_T
|
|
|
+ name: Defrost start temperature
|
|
|
class: temperature
|
|
|
category: config
|
|
|
dps:
|
|
|
@@ -421,8 +435,8 @@ entities:
|
|
|
range:
|
|
|
min: -15
|
|
|
max: -1
|
|
|
- - entity: number # defrost stop temperature
|
|
|
- name: Abtau_Tstopp # ew_AbtauenEnde_T
|
|
|
+ - entity: number
|
|
|
+ name: Defrost stop temperature
|
|
|
class: temperature
|
|
|
category: config
|
|
|
dps:
|
|
|
@@ -433,8 +447,8 @@ entities:
|
|
|
range:
|
|
|
min: 1
|
|
|
max: 40
|
|
|
- - entity: number # defrost hysteresis (delta temperature)
|
|
|
- name: Abtau_dT # ew_Abtauen_dT (Hysterese)
|
|
|
+ - entity: number
|
|
|
+ name: Defrost hysteresis
|
|
|
class: temperature
|
|
|
category: config
|
|
|
dps:
|
|
|
@@ -445,8 +459,8 @@ entities:
|
|
|
range:
|
|
|
min: 0
|
|
|
max: 15
|
|
|
- - entity: number # compressor minimal frequency @ target temperature
|
|
|
- name: Kompressor_fMin @Zieltemperatur # ew_fMin_at_ZielTemp
|
|
|
+ - entity: number
|
|
|
+ name: Minimum compressor frequency
|
|
|
class: frequency
|
|
|
category: config
|
|
|
dps:
|
|
|
@@ -457,8 +471,8 @@ entities:
|
|
|
range:
|
|
|
min: 30
|
|
|
max: 120
|
|
|
- - entity: number # compressor maximal frequency @ target temperature
|
|
|
- name: Kompressor_fMax @Zieltemperatur # ew_fMax_at_ZielTemp
|
|
|
+ - entity: number
|
|
|
+ name: Maximum compressor frequency
|
|
|
class: frequency
|
|
|
category: config
|
|
|
dps:
|
|
|
@@ -469,8 +483,8 @@ entities:
|
|
|
range:
|
|
|
min: 30
|
|
|
max: 120
|
|
|
- - entity: number # compressor hot water frequency compensation
|
|
|
- name: Kompressor_fWW-Kompensation # ew_fWarmwasser_Kompensation
|
|
|
+ - entity: number
|
|
|
+ name: Compressor hot water frequency compensation
|
|
|
class: frequency
|
|
|
category: config
|
|
|
dps:
|