@@ -0,0 +1,88 @@
|
|
|
+name: Grill
|
|
|
+products:
|
|
|
+ - id: js3ouva4uggbifzo
|
|
|
+ manufacturer: RecTeq
|
|
|
+ model: RT-800DB
|
|
|
+entities:
|
|
|
+ - entity: climate
|
|
|
+ icon: "mdi:grill"
|
|
|
+ dps:
|
|
|
+ - id: 1
|
|
|
+ type: boolean
|
|
|
+ name: hvac_mode
|
|
|
+ mapping:
|
|
|
+ - dps_val: false
|
|
|
+ value: "off"
|
|
|
+ - dps_val: true
|
|
|
+ value: heat
|
|
|
+ - id: 101
|
|
|
+ type: integer
|
|
|
+ name: temperature
|
|
|
+ range:
|
|
|
+ min: 180
|
|
|
+ max: 700
|
|
|
+ unit: F
|
|
|
+ - id: 102
|
|
|
+ type: integer
|
|
|
+ name: current_temperature
|
|
|
+ unit: F
|
|
|
+ - entity: sensor
|
|
|
+ name: Probe A temperature
|
|
|
+ class: temperature
|
|
|
+ dps:
|
|
|
+ - id: 103
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: F
|
|
|
+ - entity: sensor
|
|
|
+ name: Probe B temperature
|
|
|
+ class: temperature
|
|
|
+ dps:
|
|
|
+ - id: 104
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: F
|
|
|
+ - entity: number
|
|
|
+ name: Minimum feed rate
|
|
|
+ dps:
|
|
|
+ - id: 105
|
|
|
+ type: integer
|
|
|
+ name: value
|
|
|
+ range:
|
|
|
+ min: 0
|
|
|
+ max: 255
|
|
|
+ mapping:
|
|
|
+ - step: 5
|
|
|
+ - entity: number
|
|
|
+ translation_key: temperature_calibration
|
|
|
+ class: temperature_delta
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 106
|
|
|
+ type: integer
|
|
|
+ name: value
|
|
|
+ unit: F
|
|
|
+ range:
|
|
|
+ min: -127
|
|
|
+ max: 128
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Power failure
|
|
|
+ class: problem
|
|
|
+ dps:
|
|
|
+ - id: 107
|
|
|
+ type: boolean
|
|
|
+ name: sensor
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Ignition failure
|
|
|
+ class: problem
|
|
|
+ dps:
|
|
|
+ - id: 108
|
|
|
+ type: boolean
|
|
|
+ name: sensor
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Probe fault
|
|
|
+ class: problem
|
|
|
+ dps:
|
|
|
+ - id: 109
|
|
|
+ type: boolean
|
|
|
+ name: sensor
|