Просмотр исходного кода

remove feyree_wallbox, leaving only the combined feyree_ev_charger

Erőss Elemér 1 год назад
Родитель
Сommit
5c75591c47
1 измененных файлов с 0 добавлено и 289 удалено
  1. 0 289
      custom_components/tuya_local/devices/feyree_wallbox.yaml

+ 0 - 289
custom_components/tuya_local/devices/feyree_wallbox.yaml

@@ -1,289 +0,0 @@
-name: Feyree EV wallbox
-products:
-  - id: emvuyyax4lekiooj
-    name: A_32A_1L ChargePoint
-primary_entity:
-  entity: sensor
-  class: enum
-  name: Status
-  icon: "mdi:ev-station"
-  dps:
-    - id: 101
-      type: string
-      name: sensor
-      mapping:
-        - dps_val: no_connect
-          value: Disconnected
-        - dps_val: connect
-          value: Connected
-        - dps_val: charing            # typo from tuya
-          value: Charging
-        - dps_val: wait_rfid
-          value: Waiting for authorization
-        - dps_val: finish
-          value: Charged
-        - dps_val: wait_charing       # typo from tuya
-          value: Delaying charge
-        - dps_val: error
-          value: Error
-    - id: 3
-      type: string
-      optional: true
-      name: charger_status
-    - id: 11
-      type: string
-      optional: true
-      name: alarm_set_1
-    - id: 12
-      type: string
-      optional: true
-      name: alarm_set_2
-    - id: 14
-      type: string
-      optional: true
-      name: mode
-      mapping:
-        - dps_val: charge_now
-        - dps_val: charge_pct
-        - dps_val: charge_energy
-        - dps_val: charge_schedule
-    - id: 15
-      type: integer
-      optional: true
-      name: balance_energy
-      unit: kWh
-    - id: 18
-      type: string
-      optional: true
-      name: Meter ID
-      # 1. Device number
-      # 2, big-endian mode, string type
-      # 3, unit precision
-      # 4, message format
-      # 5, communication logic
-      # A, report three times during network configuration to
-      #    ensure successful reporting. If the pairing is successful,
-      #    the device number will be displayed on the panel.
-      # B, if the pairing is successful and the device number is not
-      #    displayed on the panel, you need to remove the device and
-      #    configure it again.
-      # C, every time the meter is powered on, it is also reported.
-    - id: 23
-      type: string
-      optional: true
-      name: system_version
-    - id: 25
-      type: integer
-      optional: true
-      name: charge_energy_once
-      unit: kWh
-    - id: 27
-      type: string
-      optional: true
-      name: online_state
-secondary_entities:
-  - entity: sensor
-    name: Alarm event
-    icon: 'mdi:alert-outline'
-    class: enum
-    dps:
-      - id: 10
-        type: bitfield
-        name: sensor
-        mapping:
-          - dps_val: 0
-            value: "Ready"
-          - dps_val: 1
-            value: "Under voltage protection"
-          - dps_val: 2
-            value: "Over voltage protection"
-          - dps_val: 3
-            value: "Over current protection"
-          - dps_val: 4
-            value: "Protective earth error"
-          - dps_val: 5
-            value: "Temperature is to high"
-          - dps_val: 6
-            value: "Control pilot line error"
-          - dps_val: 7
-            value: "Leak"
-          - dps_val: 8
-            value: "Relay socket"
-          - dps_val: 9
-            value: "Protective earth error 2"
-          - dps_val: 10
-            value: "Plug temperature is to high."
-          - dps_val: 11
-            value: "PCB temperature is to high."
-          - dps_val: 12
-            value: "Core temperature is to high."
-          - dps_val: 13
-            value: "ESB"
-          - dps_val: 14
-            value: "Socket protective earth error"
-          - dps_val: 15
-            value: "Socket leakage"
-          - dps_val: 16
-            value: "Socket temperature is to high."
-  - entity: button
-    name: Clear energy
-    class: restart
-    category: config
-    dps:
-      - id: 16
-        type: boolean
-        name: button
-        optional: true
-  - entity: button
-    name: Clear event
-    class: restart
-    category: config
-    dps:
-      - id: 20
-        type: boolean
-        name: button
-        optional: true
-  - entity: number
-    name: Set charge current
-    icon: "mdi:ev-plug-type2"
-    dps:
-      - id: 102
-        type: integer
-        name: value
-        unit: A
-        range:
-          min: 8
-          max: 32
-  - entity: switch
-    name: Leak enable
-    category: config
-    dps:
-      - id: 103
-        type: boolean
-        optional: true
-        force: true
-        name: switch
-        mapping:
-          - dps_val: false
-            value: false
-            default: true
-          - dps_val: true
-            value: true
-  - entity: number
-    name: Charge delay
-    category: config
-    icon: "mdi:car-clock"
-    dps:
-      - id: 104
-        type: integer
-        name: value
-        unit: h
-        range:
-          min: 0
-          max: 15
-  - entity: switch
-    name: Power switch
-    icon: "mdi:power"
-    category: config
-    dps:
-      - id: 105
-        type: boolean
-        optional: true
-        force: true
-        name: switch
-  - entity: sensor
-    class: energy
-    dps:
-      - id: 106
-        type: integer
-        name: sensor
-        unit: kWh
-        class: measurement
-        mapping:
-          - scale: 10
-  - entity: sensor
-    class: voltage
-    category: diagnostic
-    dps:
-      - id: 107
-        type: integer
-        name: sensor
-        unit: V
-        class: measurement
-  - entity: sensor
-    class: current
-    dps:
-      - id: 108
-        type: integer
-        name: sensor
-        unit: A
-        class: measurement
-        mapping:
-          - scale: 10
-  - entity: sensor
-    class: power
-    dps:
-      - id: 109
-        type: integer
-        name: sensor
-        unit: kW
-        class: measurement
-        mapping:
-          - scale: 10
-  - entity: sensor
-    class: temperature
-    category: diagnostic
-    dps:
-      - id: 110
-        type: integer
-        name: sensor
-        unit: C
-        class: measurement
-        mapping:
-          - scale: 10
-  - entity: number
-    name: Leakage calibration
-    category: config
-    dps:
-      - id: 111
-        type: integer
-        name: value
-        optional: true
-        force: true
-        range:
-          min: 20
-          max: 250
-        mapping:
-          - dps_val: 20
-            value: 20
-            default: true
-  - entity: button
-    name: Toggle charging       # Rfid Switch
-    dps:
-      - id: 112
-        type: boolean
-        name: button
-  - entity: sensor
-    name: Charging time
-    class: duration
-    category: diagnostic
-    dps:
-      - id: 113
-        type: integer
-        name: sensor
-        unit: h
-        class: measurement
-        mapping:
-          - scale: 10
-  - entity: number
-    name: Charging duration
-    category: config
-    icon: "mdi:car-clock"
-    dps:
-      - id: 114
-        type: integer
-        name: value
-        unit: h
-        range:
-          min: 0
-          max: 15