@@ -0,0 +1,565 @@
|
|
|
+name: EV charger
|
|
|
+products:
|
|
|
+ - id: bf2dedfe80f14bc81czzwo
|
|
|
+ manufacturer: Dowell Technology Co., Ltd.
|
|
|
+ model: DCHS-K7 #(Dowell iOneAIO ESS - 32A - 7kW)
|
|
|
+entities:
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: status
|
|
|
+ icon: "mdi:ev-station"
|
|
|
+ class: enum
|
|
|
+ dps:
|
|
|
+ - id: 3 # work_state
|
|
|
+ type: string
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: charger_charging
|
|
|
+ value: charging
|
|
|
+ - dps_val: charger_free
|
|
|
+ value: available
|
|
|
+ - dps_val: charger_insert
|
|
|
+ value: plugged_in
|
|
|
+ - dps_val: charger_free_fault
|
|
|
+ value: fault_unplugged
|
|
|
+ - dps_val: charger_wait
|
|
|
+ value: waiting
|
|
|
+ - dps_val: charger_pause
|
|
|
+ value: paused
|
|
|
+ - dps_val: charger_end
|
|
|
+ value: charged
|
|
|
+ - dps_val: charger_fault
|
|
|
+ value: fault
|
|
|
+ - entity: sensor
|
|
|
+ name: meter_id
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 22 # meter_id
|
|
|
+ type: string
|
|
|
+ name: sensor
|
|
|
+ - entity: sensor
|
|
|
+ category: diagnostic
|
|
|
+ name: system_version
|
|
|
+ dps:
|
|
|
+ - id: 23 # system_version
|
|
|
+ type: string
|
|
|
+ name: sensor
|
|
|
+ - entity: sensor
|
|
|
+ name: Total electricity consumption
|
|
|
+ class: energy
|
|
|
+ dps:
|
|
|
+ - id: 1 # forward_energy_total
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ class: total_increasing
|
|
|
+ unit: kWh
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: sensor
|
|
|
+ category: diagnostic
|
|
|
+ class: battery
|
|
|
+ dps:
|
|
|
+ - id: 2 # battery_percentage
|
|
|
+ type: integer
|
|
|
+ optional: true
|
|
|
+ name: sensor
|
|
|
+ unit: "%"
|
|
|
+ - entity: number
|
|
|
+ name: Maximum charging current
|
|
|
+ category: config
|
|
|
+ class: current
|
|
|
+ mode: box
|
|
|
+ icon: "mdi:current-ac"
|
|
|
+ dps:
|
|
|
+ - id: 4 # charge_cur_set
|
|
|
+ type: integer
|
|
|
+ name: value
|
|
|
+ unit: A
|
|
|
+ optional: true
|
|
|
+ range:
|
|
|
+ min: 6
|
|
|
+ max: 80
|
|
|
+ mapping:
|
|
|
+ - scale: 1
|
|
|
+ - entity: number
|
|
|
+ name: Household load balancing
|
|
|
+ category: config
|
|
|
+ class: current
|
|
|
+ mode: box
|
|
|
+ icon: "mdi:current-ac"
|
|
|
+ dps:
|
|
|
+ - id: 107 # dlb_cur_set
|
|
|
+ type: integer
|
|
|
+ name: value
|
|
|
+ unit: A
|
|
|
+ optional: true
|
|
|
+ range:
|
|
|
+ min: 10
|
|
|
+ max: 140
|
|
|
+ mapping:
|
|
|
+ - scale: 1
|
|
|
+ - entity: sensor
|
|
|
+ class: power
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9 # power_total
|
|
|
+ type: integer
|
|
|
+ optional: true
|
|
|
+ name: sensor
|
|
|
+ unit: kW
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: binary_sensor
|
|
|
+ class: problem
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 10 # fault
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: 0
|
|
|
+ value: false
|
|
|
+ - value: true
|
|
|
+ - id: 10 # fault
|
|
|
+ type: bitfield
|
|
|
+ name: fault_code
|
|
|
+ - id: 10 # fault
|
|
|
+ type: bitfield
|
|
|
+ name: description
|
|
|
+ mapping:
|
|
|
+ - dps_val: 0
|
|
|
+ value: ov_cr
|
|
|
+ - dps_val: 1
|
|
|
+ value: ov2_cr_fault
|
|
|
+ - dps_val: 2
|
|
|
+ value: ov_vol
|
|
|
+ - dps_val: 4
|
|
|
+ value: undervoltage_alarm
|
|
|
+ - dps_val: 8
|
|
|
+ value: contactor_adhesion
|
|
|
+ - dps_val: 16
|
|
|
+ value: contactor_fault
|
|
|
+ - dps_val: 32
|
|
|
+ value: earth_fault
|
|
|
+ - dps_val: 64
|
|
|
+ value: meter_hardware_alarm
|
|
|
+ - dps_val: 128
|
|
|
+ value: scram_fault
|
|
|
+ - dps_val: 256
|
|
|
+ value: cp_fault
|
|
|
+ - dps_val: 512
|
|
|
+ value: meter_commu_fault
|
|
|
+ - dps_val: 1024
|
|
|
+ value: card_reader_fault
|
|
|
+ - dps_val: 2048
|
|
|
+ value: cir_short_fault
|
|
|
+ - dps_val: 4096
|
|
|
+ value: adhesion_fault
|
|
|
+ - dps_val: 8192
|
|
|
+ value: self_test_alarm
|
|
|
+ - dps_val: 16384
|
|
|
+ value: leakagecurr_alarm
|
|
|
+ - entity: sensor
|
|
|
+ name: Connection
|
|
|
+ icon: "mdi:ev-plug-type2"
|
|
|
+ class: enum
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 13 # connection_state
|
|
|
+ type: string
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: controlpi_12v
|
|
|
+ value: Standby
|
|
|
+ - dps_val: controlpi_12v_pwm
|
|
|
+ value: Communication initialising
|
|
|
+ - dps_val: controlpi_9v
|
|
|
+ value: Vehicle detected
|
|
|
+ - dps_val: controlpi_9v_pwm
|
|
|
+ value: Vehicle connected
|
|
|
+ - dps_val: controlpi_6v
|
|
|
+ value: Ready to charge
|
|
|
+ - dps_val: controlpi_6v_pwm
|
|
|
+ value: Charging
|
|
|
+ - dps_val: controlpi_error
|
|
|
+ value: Error
|
|
|
+ - entity: select
|
|
|
+ name: Charging mode
|
|
|
+ icon: "mdi:ev-station"
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 14 # work_mode
|
|
|
+ type: string
|
|
|
+ optional: true
|
|
|
+ name: option
|
|
|
+ mapping:
|
|
|
+ - dps_val: charge_now
|
|
|
+ value: Plug and Play
|
|
|
+ - dps_val: charge_energy
|
|
|
+ value: Normal mode
|
|
|
+ - dps_val: charge_schedule
|
|
|
+ value: Scheduled
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: voltage_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: A
|
|
|
+ class: voltage
|
|
|
+ dps:
|
|
|
+ - id: 6 # phase_a
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: V
|
|
|
+ mask: "FFFF000000000000"
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: current_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: A
|
|
|
+ class: current
|
|
|
+ dps:
|
|
|
+ - id: 6 # phase_a
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: A
|
|
|
+ mask: "0000FFFFFF000000"
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: power_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: A
|
|
|
+ class: power
|
|
|
+ dps:
|
|
|
+ - id: 6 # phase_a
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: kW
|
|
|
+ mask: "0000000000FFFFFF"
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: voltage_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: B
|
|
|
+ class: voltage
|
|
|
+ dps:
|
|
|
+ - id: 7 # phase_b
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: V
|
|
|
+ mask: "FFFF000000000000"
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: current_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: B
|
|
|
+ class: current
|
|
|
+ dps:
|
|
|
+ - id: 7 # phase_b
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: A
|
|
|
+ mask: "0000FFFFFF000000"
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: power_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: B
|
|
|
+ class: power
|
|
|
+ dps:
|
|
|
+ - id: 7 # phase_b
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: kW
|
|
|
+ mask: "0000000000FFFFFF"
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: voltage_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: C
|
|
|
+ class: voltage
|
|
|
+ dps:
|
|
|
+ - id: 8 # phase_c
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: V
|
|
|
+ mask: "FFFF000000000000"
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: current_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: C
|
|
|
+ class: current
|
|
|
+ dps:
|
|
|
+ - id: 8 # phase_c
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: A
|
|
|
+ mask: "0000FFFFFF000000"
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: power_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: C
|
|
|
+ class: power
|
|
|
+ dps:
|
|
|
+ - id: 8 # phase_c
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: kW
|
|
|
+ mask: "0000000000FFFFFF"
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ class: temperature
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 24 # temp_current
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: C
|
|
|
+ class: measurement
|
|
|
+ - entity: number
|
|
|
+ name: Remaining available power
|
|
|
+ category: diagnostic
|
|
|
+ class: energy_storage
|
|
|
+ dps:
|
|
|
+ - id: 15 # balance_energy
|
|
|
+ type: integer
|
|
|
+ optional: true
|
|
|
+ name: value
|
|
|
+ unit: kWh
|
|
|
+ range:
|
|
|
+ min: 0
|
|
|
+ max: 99999999
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: number
|
|
|
+ name: energy_charge
|
|
|
+ category: diagnostic
|
|
|
+ class: energy_storage
|
|
|
+ dps:
|
|
|
+ - id: 17 # energy_charge
|
|
|
+ type: integer
|
|
|
+ optional: true
|
|
|
+ name: value
|
|
|
+ unit: kWh
|
|
|
+ range:
|
|
|
+ min: 1
|
|
|
+ max: 20000000
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: number
|
|
|
+ name: Charge time
|
|
|
+ category: config
|
|
|
+ class: duration
|
|
|
+ icon: "mdi:timer"
|
|
|
+ dps:
|
|
|
+ - id: 19 # charge_time
|
|
|
+ type: integer
|
|
|
+ optional: true
|
|
|
+ name: value
|
|
|
+ unit: min
|
|
|
+ range:
|
|
|
+ min: 1
|
|
|
+ max: 1440
|
|
|
+ - entity: sensor
|
|
|
+ name: Charge energy
|
|
|
+ class: energy_storage
|
|
|
+ dps:
|
|
|
+ - id: 25 # charge_energy_once
|
|
|
+ type: integer
|
|
|
+ optional: true
|
|
|
+ name: value
|
|
|
+ unit: kWh
|
|
|
+ range:
|
|
|
+ min: 1
|
|
|
+ max: 20000000
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: switch
|
|
|
+ icon: "mdi:ev-station"
|
|
|
+ dps:
|
|
|
+ - id: 18 # switch
|
|
|
+ type: boolean
|
|
|
+ name: switch
|
|
|
+ - entity: sensor
|
|
|
+ name: Charging time
|
|
|
+ class: duration
|
|
|
+ dps:
|
|
|
+ - id: 101 # charging_time1
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: s
|
|
|
+ mask: "0000FFFF"
|
|
|
+ - entity: select
|
|
|
+ name: Mode
|
|
|
+ icon: "mdi:cogs"
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 102 # mode
|
|
|
+ type: string
|
|
|
+ optional: true
|
|
|
+ name: option
|
|
|
+ mapping:
|
|
|
+ - dps_val: home
|
|
|
+ value: Home
|
|
|
+ - dps_val: mode
|
|
|
+ value: Mode
|
|
|
+ - dps_val: recode
|
|
|
+ value: Recode
|
|
|
+ - dps_val: setting
|
|
|
+ value: Setting
|
|
|
+ - entity: sensor
|
|
|
+ name: Minimum current
|
|
|
+ class: current
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 103 # current_limit
|
|
|
+ type: base64
|
|
|
+ optional: true
|
|
|
+ name: sensor
|
|
|
+ unit: A
|
|
|
+ mask: "FFFF0000"
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ name: Maximum current
|
|
|
+ class: current
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 103 # current_limit
|
|
|
+ type: base64
|
|
|
+ optional: true
|
|
|
+ name: sensor
|
|
|
+ unit: A
|
|
|
+ mask: "0000FFFF"
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: button
|
|
|
+ name: Reset energy counter
|
|
|
+ class: restart
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 16 # clear_energy
|
|
|
+ type: boolean
|
|
|
+ optional: true
|
|
|
+ name: button
|
|
|
+ - entity: select
|
|
|
+ name: online_state
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 27 # online_state
|
|
|
+ type: string
|
|
|
+ optional: true
|
|
|
+ name: option
|
|
|
+ mapping:
|
|
|
+ - dps_val: offline
|
|
|
+ value: offline
|
|
|
+ - dps_val: online
|
|
|
+ value: online
|
|
|
+ - entity: switch
|
|
|
+ name: rf_enable
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 110 # rf_enable
|
|
|
+ type: boolean
|
|
|
+ optional: true
|
|
|
+ name: switch
|
|
|
+ - entity: switch
|
|
|
+ name: pen_enable
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 108 # pen_enable
|
|
|
+ type: boolean
|
|
|
+ optional: true
|
|
|
+ name: switch
|
|
|
+ - entity: binary_sensor
|
|
|
+ class: safety
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 106 # safety_notice
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: 0
|
|
|
+ value: false
|
|
|
+ - value: true
|
|
|
+ - id: 106 # safety_notice
|
|
|
+ type: bitfield
|
|
|
+ name: fault_code
|
|
|
+ - id: 106 # safety_notice
|
|
|
+ type: bitfield
|
|
|
+ name: description
|
|
|
+ mapping:
|
|
|
+ - dps_val: 0
|
|
|
+ value: software_safety
|
|
|
+ - dps_val: 1
|
|
|
+ value: case_open
|
|
|
+ - dps_val: 2
|
|
|
+ value: lock_fault
|
|
|
+ - dps_val: 4
|
|
|
+ value: software_change
|
|
|
+ - entity: text
|
|
|
+ name: occp_ip
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 104 # occp_ip
|
|
|
+ type: string
|
|
|
+ optional: true
|
|
|
+ name: value
|
|
|
+ - entity: text
|
|
|
+ name: occp_port
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 105 # occp_port
|
|
|
+ type: string
|
|
|
+ optional: true
|
|
|
+ name: value
|
|
|
+ - entity: text
|
|
|
+ name: password
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 109 # password
|
|
|
+ type: string
|
|
|
+ hidden: true
|
|
|
+ optional: true
|
|
|
+ name: value
|
|
|
+ - entity: text
|
|
|
+ name: car_binding
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 21 # car_binding
|
|
|
+ type: string
|
|
|
+ optional: true
|
|
|
+ name: value
|
|
|
+ - entity: sensor
|
|
|
+ name: alarm_set_1
|
|
|
+ dps:
|
|
|
+ - id: 11 # alarm_set_1
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ - entity: sensor
|
|
|
+ name: alarm_set_2
|
|
|
+ dps:
|
|
|
+ - id: 12 # alarm_set_2
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|