|
|
@@ -1,234 +0,0 @@
|
|
|
-name: Pool pump
|
|
|
-products:
|
|
|
- - id: i0elff0w1pehctax
|
|
|
- manufacturer: AquaForte
|
|
|
- model: Inverter VSP
|
|
|
-entities:
|
|
|
- - entity: valve
|
|
|
- class: water
|
|
|
- dps:
|
|
|
- - id: 105
|
|
|
- type: boolean
|
|
|
- name: valve
|
|
|
- - entity: select
|
|
|
- name: Pump mode
|
|
|
- icon: "mdi:pump"
|
|
|
- category: config
|
|
|
- dps:
|
|
|
- - id: 103
|
|
|
- type: string
|
|
|
- name: option
|
|
|
- mapping:
|
|
|
- - dps_val: "MI"
|
|
|
- value: "Manual"
|
|
|
- - dps_val: "AI"
|
|
|
- value: "AI Flow"
|
|
|
- - dps_val: "backwash"
|
|
|
- value: "Boost"
|
|
|
- - entity: select
|
|
|
- name: Pump flow units
|
|
|
- category: config
|
|
|
- dps:
|
|
|
- - id: 110
|
|
|
- type: string
|
|
|
- name: option
|
|
|
- mapping:
|
|
|
- - dps_val: "m3_h"
|
|
|
- value: "m³/h"
|
|
|
- - dps_val: "l_min"
|
|
|
- value: "L/min"
|
|
|
- - dps_val: "us_gpm"
|
|
|
- value: "US gpm"
|
|
|
- - dps_val: "ipm_gpm"
|
|
|
- value: "Imperial gpm"
|
|
|
- - entity: number
|
|
|
- name: Boost timer
|
|
|
- translation_key: timer
|
|
|
- class: duration
|
|
|
- category: config
|
|
|
- mode: box
|
|
|
- dps:
|
|
|
- - id: 104
|
|
|
- type: integer
|
|
|
- name: value
|
|
|
- range:
|
|
|
- min: 0
|
|
|
- max: 1500
|
|
|
- unit: s
|
|
|
- - entity: number
|
|
|
- name: AI flow rate
|
|
|
- class: volume_flow_rate
|
|
|
- category: config
|
|
|
- mode: slider
|
|
|
- dps:
|
|
|
- - id: 106
|
|
|
- type: integer
|
|
|
- name: value
|
|
|
- range:
|
|
|
- min: 0
|
|
|
- max: 1000
|
|
|
- - id: 101
|
|
|
- type: integer
|
|
|
- name: maximum
|
|
|
- - id: 107
|
|
|
- type: integer
|
|
|
- name: minimum
|
|
|
- - id: 113
|
|
|
- type: integer
|
|
|
- name: step
|
|
|
- - id: 110
|
|
|
- type: string
|
|
|
- name: unit
|
|
|
- mapping:
|
|
|
- - dps_val: "m3_h"
|
|
|
- value: "m³/h"
|
|
|
- - dps_val: "l_min"
|
|
|
- value: "L/min"
|
|
|
- - dps_val: "us_gpm"
|
|
|
- value: "gal/min"
|
|
|
- - dps_val: "ipm_gpm"
|
|
|
- value: "gal/min"
|
|
|
- - entity: number
|
|
|
- name: Manual percentage power
|
|
|
- category: config
|
|
|
- mode: slider
|
|
|
- dps:
|
|
|
- - id: 111
|
|
|
- type: integer
|
|
|
- name: value
|
|
|
- range:
|
|
|
- min: 30
|
|
|
- max: 120
|
|
|
- unit: "%"
|
|
|
- - entity: sensor
|
|
|
- name: Boost time remaining
|
|
|
- class: duration
|
|
|
- category: diagnostic
|
|
|
- dps:
|
|
|
- - id: 108
|
|
|
- type: integer
|
|
|
- name: sensor
|
|
|
- unit: s
|
|
|
- - entity: sensor
|
|
|
- class: power
|
|
|
- category: diagnostic
|
|
|
- dps:
|
|
|
- - id: 5
|
|
|
- type: integer
|
|
|
- name: sensor
|
|
|
- unit: W
|
|
|
- - entity: sensor
|
|
|
- class: volume_flow_rate
|
|
|
- category: diagnostic
|
|
|
- dps:
|
|
|
- - id: 112
|
|
|
- type: integer
|
|
|
- name: sensor
|
|
|
- - id: 110
|
|
|
- type: string
|
|
|
- name: unit
|
|
|
- mapping:
|
|
|
- - dps_val: "m3_h"
|
|
|
- value: "m³/h"
|
|
|
- - dps_val: "l_min"
|
|
|
- value: "L/min"
|
|
|
- - dps_val: "us_gpm"
|
|
|
- value: "gal/min"
|
|
|
- - dps_val: "ipm_gpm"
|
|
|
- value: "gal/min"
|
|
|
- - entity: sensor
|
|
|
- class: energy
|
|
|
- category: diagnostic
|
|
|
- dps:
|
|
|
- - id: 109
|
|
|
- type: integer
|
|
|
- name: sensor
|
|
|
- class: total_increasing
|
|
|
- unit: kWh
|
|
|
- mapping:
|
|
|
- - scale: 100
|
|
|
- - entity: sensor
|
|
|
- name: Actual pump speed
|
|
|
- category: diagnostic
|
|
|
- dps:
|
|
|
- - id: 102
|
|
|
- type: integer
|
|
|
- name: sensor
|
|
|
- unit: "%"
|
|
|
- range:
|
|
|
- min: 30
|
|
|
- max: 120
|
|
|
- - entity: binary_sensor
|
|
|
- category: diagnostic
|
|
|
- class: problem
|
|
|
- dps:
|
|
|
- - id: 2
|
|
|
- type: bitfield
|
|
|
- name: sensor
|
|
|
- mapping:
|
|
|
- - dps_val: 0
|
|
|
- value: false
|
|
|
- - value: true
|
|
|
- - id: 2
|
|
|
- type: bitfield
|
|
|
- name: fault_code
|
|
|
- - id: 2
|
|
|
- type: bitfield
|
|
|
- name: description
|
|
|
- mapping:
|
|
|
- - dps_val: 0
|
|
|
- value: "None"
|
|
|
- - dps_val: "E001"
|
|
|
- value: "E001 - Abnormal input voltage"
|
|
|
- - dps_val: "E002"
|
|
|
- value: "E002 - Output over current"
|
|
|
- - dps_val: "E101"
|
|
|
- value: "E101 - Heat sink over heat"
|
|
|
- - dps_val: "E102"
|
|
|
- value: "E102 - Heat sink sensor error"
|
|
|
- - dps_val: "E103"
|
|
|
- value: "E103 - Master driver board error"
|
|
|
- - dps_val: "E104"
|
|
|
- value: "E104 - Phase-deficient protection"
|
|
|
- - dps_val: "E105"
|
|
|
- value: "E105 - AC current sampling circuit failure"
|
|
|
- - dps_val: "E106"
|
|
|
- value: "E106 - DC abnormal voltage"
|
|
|
- - dps_val: "E107"
|
|
|
- value: "E107 - PFC protection"
|
|
|
- - dps_val: "E108"
|
|
|
- value: "E108 - Motor power overload"
|
|
|
- - dps_val: "E201"
|
|
|
- value: "E201 - Circuit board error"
|
|
|
- - dps_val: "E202"
|
|
|
- value: "E202 - Master board EEPROM reading failure"
|
|
|
- - dps_val: "E203"
|
|
|
- value: "E203 - RTC time reading error"
|
|
|
- - dps_val: "E204"
|
|
|
- value: "E204 - Display Board EEPROM reading failure"
|
|
|
- - dps_val: "E205"
|
|
|
- value: "E205 - Communication Error"
|
|
|
- - dps_val: "E206"
|
|
|
- value: "E206 - RS485 communication Error"
|
|
|
- - dps_val: "E207"
|
|
|
- value: "E207 - No water protection"
|
|
|
- - dps_val: "E208"
|
|
|
- value: "E208 - Pressure sensor failure"
|
|
|
- - dps_val: "E209"
|
|
|
- value: "E209 - Loss of prime"
|
|
|
- - dps_val: "AL01"
|
|
|
- value: "AL01 - High temperature warning deceleration"
|
|
|
- - dps_val: "AL02"
|
|
|
- value: "AL02 - AC voltage low droop"
|
|
|
- - dps_val: "AL03"
|
|
|
- value: "AL03 - Anti Freezing"
|
|
|
- - dps_val: "E003"
|
|
|
- value: "E003 - No water protection"
|
|
|
- - entity: binary_sensor
|
|
|
- name: Flow pressure warning
|
|
|
- category: diagnostic
|
|
|
- class: problem
|
|
|
- dps:
|
|
|
- - id: 114
|
|
|
- type: boolean
|
|
|
- name: sensor
|