@@ -0,0 +1,403 @@
|
|
|
+# AmperePoint Q Series capability profile.
|
|
|
+# Product IDs are sourced from the AmperePoint Tuya product export. Optional
|
|
|
+# entities are exposed only when their datapoints are reported by the device.
|
|
|
+name: EV charger
|
|
|
+products:
|
|
|
+ - id: kvldga0omutrnify
|
|
|
+ manufacturer: AmperePoint
|
|
|
+ model: Q Series
|
|
|
+ - id: anmnwqqojlg9og2t
|
|
|
+ manufacturer: AmperePoint
|
|
|
+ model: Q Series
|
|
|
+ - id: pt6e5u40nasunnsp
|
|
|
+ manufacturer: AmperePoint
|
|
|
+ model: Q Series
|
|
|
+ - id: g5pkcqekcb7hhnm4
|
|
|
+ manufacturer: AmperePoint
|
|
|
+ model: Q Series
|
|
|
+ - id: 1qu8ca6etdubbigj
|
|
|
+ manufacturer: AmperePoint
|
|
|
+ model: Q Series
|
|
|
+ - id: c2sgesr3zo1met7q
|
|
|
+ manufacturer: AmperePoint
|
|
|
+ model: Q Series
|
|
|
+ - id: 3axf0fkgiop0ukhb
|
|
|
+ manufacturer: AmperePoint
|
|
|
+ model: Q Series
|
|
|
+ - id: cu111poj2mtikvls
|
|
|
+ manufacturer: AmperePoint
|
|
|
+ model: Q Series
|
|
|
+ - id: jhlyzpk5nfk28nrh
|
|
|
+ manufacturer: AmperePoint
|
|
|
+ model: Q Series
|
|
|
+ - id: fdfjiphjxtc9qyhd
|
|
|
+ manufacturer: AmperePoint
|
|
|
+ model: Q Series
|
|
|
+entities:
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: status
|
|
|
+ icon: "mdi:ev-station"
|
|
|
+ class: enum
|
|
|
+ dps:
|
|
|
+ - id: 3
|
|
|
+ type: string
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: charger_charging
|
|
|
+ value: charging
|
|
|
+ - dps_val: charger_free
|
|
|
+ value: available
|
|
|
+ - dps_val: charger_insert
|
|
|
+ value: plugged_in
|
|
|
+ - dps_val: charger_free_fault
|
|
|
+ value: fault_unplugged
|
|
|
+ - dps_val: charger_wait
|
|
|
+ value: waiting
|
|
|
+ - dps_val: charger_pause
|
|
|
+ value: paused
|
|
|
+ - dps_val: charger_end
|
|
|
+ value: charged
|
|
|
+ - dps_val: charger_fault
|
|
|
+ value: fault
|
|
|
+ - id: 23
|
|
|
+ type: string
|
|
|
+ optional: true
|
|
|
+ name: system_version
|
|
|
+ - entity: sensor
|
|
|
+ class: energy
|
|
|
+ dps:
|
|
|
+ - id: 1
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kWh
|
|
|
+ class: total_increasing
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: number
|
|
|
+ name: Charging current
|
|
|
+ category: config
|
|
|
+ class: current
|
|
|
+ icon: "mdi:ev-plug-type2"
|
|
|
+ dps:
|
|
|
+ - id: 4
|
|
|
+ type: integer
|
|
|
+ name: value
|
|
|
+ unit: A
|
|
|
+ range:
|
|
|
+ min: 6
|
|
|
+ max: 32
|
|
|
+ # When present, a phase payload is 7 bytes: voltage /10 V,
|
|
|
+ # current /1000 A and power /1000 kW. These entities stay disabled by
|
|
|
+ # default because some firmware reports malformed phase payloads.
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: voltage_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: A
|
|
|
+ class: voltage
|
|
|
+ category: diagnostic
|
|
|
+ hidden: true
|
|
|
+ dps:
|
|
|
+ - id: 6
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: V
|
|
|
+ mask: "FFFF0000000000"
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: current_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: A
|
|
|
+ class: current
|
|
|
+ category: diagnostic
|
|
|
+ hidden: true
|
|
|
+ dps:
|
|
|
+ - id: 6
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: A
|
|
|
+ mask: "0000FFFFFF0000"
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: power_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: A
|
|
|
+ class: power
|
|
|
+ category: diagnostic
|
|
|
+ hidden: true
|
|
|
+ dps:
|
|
|
+ - id: 6
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: kW
|
|
|
+ class: measurement
|
|
|
+ mask: "0000000000FFFF"
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: voltage_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: B
|
|
|
+ class: voltage
|
|
|
+ category: diagnostic
|
|
|
+ hidden: true
|
|
|
+ dps:
|
|
|
+ - id: 7
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: V
|
|
|
+ mask: "FFFF0000000000"
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: current_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: B
|
|
|
+ class: current
|
|
|
+ category: diagnostic
|
|
|
+ hidden: true
|
|
|
+ dps:
|
|
|
+ - id: 7
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: A
|
|
|
+ mask: "0000FFFFFF0000"
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: power_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: B
|
|
|
+ class: power
|
|
|
+ category: diagnostic
|
|
|
+ hidden: true
|
|
|
+ dps:
|
|
|
+ - id: 7
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: kW
|
|
|
+ class: measurement
|
|
|
+ mask: "0000000000FFFF"
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: voltage_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: C
|
|
|
+ class: voltage
|
|
|
+ category: diagnostic
|
|
|
+ hidden: true
|
|
|
+ dps:
|
|
|
+ - id: 8
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: V
|
|
|
+ mask: "FFFF0000000000"
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: current_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: C
|
|
|
+ class: current
|
|
|
+ category: diagnostic
|
|
|
+ hidden: true
|
|
|
+ dps:
|
|
|
+ - id: 8
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: A
|
|
|
+ mask: "0000FFFFFF0000"
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: power_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: C
|
|
|
+ class: power
|
|
|
+ category: diagnostic
|
|
|
+ hidden: true
|
|
|
+ dps:
|
|
|
+ - id: 8
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: kW
|
|
|
+ class: measurement
|
|
|
+ mask: "0000000000FFFF"
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ class: power
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kW
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: binary_sensor
|
|
|
+ class: problem
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 10
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ mapping:
|
|
|
+ - dps_val: 0
|
|
|
+ value: false
|
|
|
+ - value: true
|
|
|
+ - id: 10
|
|
|
+ type: bitfield
|
|
|
+ name: fault_code
|
|
|
+ optional: true
|
|
|
+ - id: 10
|
|
|
+ type: bitfield
|
|
|
+ name: description
|
|
|
+ optional: true
|
|
|
+ mapping:
|
|
|
+ - dps_val: 0
|
|
|
+ value: "Ok"
|
|
|
+ - dps_val: 1
|
|
|
+ value: "Ov Cr"
|
|
|
+ - dps_val: 2
|
|
|
+ value: "Ov2 Cr Fault"
|
|
|
+ - dps_val: 4
|
|
|
+ value: "Overvoltage alarm"
|
|
|
+ - dps_val: 8
|
|
|
+ value: "Undervoltage alarm"
|
|
|
+ - dps_val: 16
|
|
|
+ value: "Contactor adhesion"
|
|
|
+ - dps_val: 32
|
|
|
+ value: "Contactor fault"
|
|
|
+ - dps_val: 64
|
|
|
+ value: "Earth fault"
|
|
|
+ - dps_val: 128
|
|
|
+ value: "Meter hardware alarm"
|
|
|
+ - dps_val: 256
|
|
|
+ value: "Scram fault"
|
|
|
+ - dps_val: 512
|
|
|
+ value: "CP fault"
|
|
|
+ - dps_val: 1024
|
|
|
+ value: "Meter communication fault"
|
|
|
+ - dps_val: 2048
|
|
|
+ value: "Card reader fault"
|
|
|
+ - dps_val: 4096
|
|
|
+ value: "Circuit short fault"
|
|
|
+ - dps_val: 8192
|
|
|
+ value: "Adhesion fault"
|
|
|
+ - dps_val: 16384
|
|
|
+ value: "Self test alarm"
|
|
|
+ - dps_val: 32768
|
|
|
+ value: "Leakage current alarm"
|
|
|
+ - dps_val: 65536
|
|
|
+ value: "Over temperature fault"
|
|
|
+ - entity: sensor
|
|
|
+ name: Connection
|
|
|
+ icon: "mdi:ev-plug-type2"
|
|
|
+ class: enum
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 13
|
|
|
+ type: string
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: controlpi_12v
|
|
|
+ value: standby
|
|
|
+ - dps_val: controlpi_12v_pwm
|
|
|
+ value: communication_initialising
|
|
|
+ - dps_val: controlpi_9v
|
|
|
+ value: vehicle_detected
|
|
|
+ - dps_val: controlpi_9v_pwm
|
|
|
+ value: vehicle_connected
|
|
|
+ - dps_val: controlpi_6v
|
|
|
+ value: ready_to_charge
|
|
|
+ - dps_val: controlpi_6v_pwm
|
|
|
+ value: charging
|
|
|
+ - dps_val: controlpi_error
|
|
|
+ value: error
|
|
|
+ - entity: select
|
|
|
+ translation_key: charging_mode
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 14
|
|
|
+ type: string
|
|
|
+ optional: true
|
|
|
+ name: option
|
|
|
+ mapping:
|
|
|
+ - dps_val: charge_now
|
|
|
+ value: immediate
|
|
|
+ - dps_val: charge_energy
|
|
|
+ value: fixed_charge
|
|
|
+ - dps_val: charge_schedule
|
|
|
+ value: scheduled_charge
|
|
|
+ - entity: number
|
|
|
+ name: Target energy
|
|
|
+ category: config
|
|
|
+ icon: "mdi:battery-charging-high"
|
|
|
+ dps:
|
|
|
+ - id: 17
|
|
|
+ type: integer
|
|
|
+ name: value
|
|
|
+ optional: true
|
|
|
+ unit: kWh
|
|
|
+ range:
|
|
|
+ min: 1
|
|
|
+ max: 200
|
|
|
+ - entity: switch
|
|
|
+ icon: "mdi:ev-station"
|
|
|
+ dps:
|
|
|
+ - id: 18
|
|
|
+ type: boolean
|
|
|
+ name: switch
|
|
|
+ - entity: sensor
|
|
|
+ name: Schedule charging payload
|
|
|
+ category: diagnostic
|
|
|
+ hidden: true
|
|
|
+ dps:
|
|
|
+ - id: 19
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ - entity: sensor
|
|
|
+ class: temperature
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 24
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: C
|
|
|
+ class: measurement
|
|
|
+ - entity: sensor
|
|
|
+ name: Last session energy
|
|
|
+ class: energy_storage
|
|
|
+ dps:
|
|
|
+ - id: 25
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ optional: true
|
|
|
+ unit: kWh
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: sensor
|
|
|
+ name: Charge mode payload
|
|
|
+ category: diagnostic
|
|
|
+ hidden: true
|
|
|
+ dps:
|
|
|
+ - id: 33
|
|
|
+ type: base64
|
|
|
+ name: sensor
|
|
|
+ optional: true
|