@@ -0,0 +1,306 @@
|
|
|
+name: Heat pump water heater
|
|
|
+products:
|
|
|
+ - id: zcuzgqkr3aef1hap
|
|
|
+ manufacturer: Aqua Plus
|
|
|
+ model: APAIO270
|
|
|
+entities:
|
|
|
+ - entity: water_heater
|
|
|
+ dps:
|
|
|
+ - id: 1
|
|
|
+ type: boolean
|
|
|
+ name: operation_mode
|
|
|
+ mapping:
|
|
|
+ - dps_val: false
|
|
|
+ value: "off"
|
|
|
+ - dps_val: true
|
|
|
+ constraint: mode
|
|
|
+ conditions:
|
|
|
+ - dps_val: Stand
|
|
|
+ value: heat_pump
|
|
|
+ - dps_val: Boost
|
|
|
+ value: performance
|
|
|
+ - dps_val: ELE
|
|
|
+ value: electric
|
|
|
+ - id: 2
|
|
|
+ type: string
|
|
|
+ name: mode
|
|
|
+ hidden: true
|
|
|
+ - id: 4
|
|
|
+ type: integer
|
|
|
+ name: temperature
|
|
|
+ unit: C
|
|
|
+ range:
|
|
|
+ min: 15
|
|
|
+ max: 75
|
|
|
+ - id: 21
|
|
|
+ type: integer
|
|
|
+ name: current_temperature
|
|
|
+ unit: C
|
|
|
+ # Target/tank temperature are intentionally not duplicated as standalone
|
|
|
+ # sensors here (see PR #5548 discussion) - only the current/measured value
|
|
|
+ # convention has precedent elsewhere in this repo, and even that was
|
|
|
+ # rejected upstream. If long-term statistics for these values are wanted,
|
|
|
+ # add `template:` sensors in your own HA config instead.
|
|
|
+ - entity: binary_sensor
|
|
|
+ translation_key: defrost
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 7
|
|
|
+ type: boolean
|
|
|
+ name: sensor
|
|
|
+ - entity: sensor
|
|
|
+ name: Expansion valve position
|
|
|
+ icon: "mdi:pipe-valve"
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 14
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ - entity: binary_sensor
|
|
|
+ class: problem
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 15
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: 0
|
|
|
+ value: false
|
|
|
+ - value: true
|
|
|
+ - id: 15
|
|
|
+ type: bitfield
|
|
|
+ name: fault_code
|
|
|
+ - entity: sensor
|
|
|
+ name: Phase sequence module
|
|
|
+ class: enum
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 17
|
|
|
+ type: string
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: "NO"
|
|
|
+ value: Nothing
|
|
|
+ # "normal" and "ERR" are unconfirmed guesses - never observed live
|
|
|
+ - dps_val: normal
|
|
|
+ value: Normal
|
|
|
+ - dps_val: ERR
|
|
|
+ value: Error
|
|
|
+ - entity: sensor
|
|
|
+ name: Fan speed
|
|
|
+ class: enum
|
|
|
+ translation_key: status
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 19
|
|
|
+ type: string
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: "OFF"
|
|
|
+ value: "off"
|
|
|
+ - dps_val: LOW
|
|
|
+ value: low
|
|
|
+ - dps_val: High
|
|
|
+ value: high
|
|
|
+ - entity: sensor
|
|
|
+ name: Suction temperature
|
|
|
+ class: temperature
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 20
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: C
|
|
|
+ class: measurement
|
|
|
+ - entity: sensor
|
|
|
+ name: Return water temperature
|
|
|
+ class: temperature
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 22
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: C
|
|
|
+ class: measurement
|
|
|
+ - entity: sensor
|
|
|
+ name: Coil temperature
|
|
|
+ class: temperature
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 23
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: C
|
|
|
+ class: measurement
|
|
|
+ - entity: sensor
|
|
|
+ name: Discharge temperature
|
|
|
+ class: temperature
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 24
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: C
|
|
|
+ class: measurement
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: ambient_temperature
|
|
|
+ class: temperature
|
|
|
+ dps:
|
|
|
+ - id: 26
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: C
|
|
|
+ class: measurement
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Compressor
|
|
|
+ class: running
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 27
|
|
|
+ type: boolean
|
|
|
+ name: sensor
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Four-way valve
|
|
|
+ class: opening
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 28
|
|
|
+ type: boolean
|
|
|
+ name: sensor
|
|
|
+ - entity: sensor
|
|
|
+ name: Circulation mode
|
|
|
+ class: enum
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 30
|
|
|
+ type: boolean
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: true
|
|
|
+ value: Fluorine
|
|
|
+ - dps_val: false
|
|
|
+ value: Water
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Low pressure switch
|
|
|
+ class: opening
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 29
|
|
|
+ type: boolean
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: true
|
|
|
+ value: false
|
|
|
+ - dps_val: false
|
|
|
+ value: true
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Water pump
|
|
|
+ class: running
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 31
|
|
|
+ type: boolean
|
|
|
+ name: sensor
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Electric heating element
|
|
|
+ class: running
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 32
|
|
|
+ type: boolean
|
|
|
+ name: sensor
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: High pressure switch
|
|
|
+ class: opening
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 33
|
|
|
+ type: boolean
|
|
|
+ name: sensor
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Linked switch
|
|
|
+ class: opening
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ # true/false to Close/Open confirmed via app; significance of the
|
|
|
+ # linkage feature itself (likely PV/solar interlock) is unconfirmed
|
|
|
+ - id: 106
|
|
|
+ type: boolean
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: true
|
|
|
+ value: false
|
|
|
+ - dps_val: false
|
|
|
+ value: true
|
|
|
+ - entity: sensor
|
|
|
+ name: Compressor runtime before defrost
|
|
|
+ class: duration
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 41
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: min
|
|
|
+ - entity: sensor
|
|
|
+ class: current
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 101
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: A
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ class: voltage
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 102
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: V
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ class: power
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 103
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: W
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ name: Total energy
|
|
|
+ class: energy
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 104
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kWh
|
|
|
+ class: total_increasing
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - id: 18
|
|
|
+ type: integer
|
|
|
+ name: daily
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: binary_sensor
|
|
|
+ name: Water flow switch
|
|
|
+ class: opening
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 107
|
|
|
+ type: boolean
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: true
|
|
|
+ value: false
|
|
|
+ - dps_val: false
|
|
|
+ value: true
|