@@ -1,239 +0,0 @@
|
|
|
-from homeassistant.components.climate.const import ClimateEntityFeature, HVACMode
|
|
|
-from homeassistant.components.number.const import NumberDeviceClass
|
|
|
-from homeassistant.components.sensor import SensorDeviceClass, SensorStateClass
|
|
|
-from homeassistant.const import UnitOfTemperature, UnitOfTime
|
|
|
-
|
|
|
-from ..const import JIAHONG_ET72W_PAYLOAD
|
|
|
-from ..mixins.climate import TargetTemperatureTests
|
|
|
-from ..mixins.lock import BasicLockTests
|
|
|
-from ..mixins.number import BasicNumberTests
|
|
|
-from ..mixins.select import MultiSelectTests
|
|
|
-from ..mixins.sensor import MultiSensorTests
|
|
|
-from .base_device_tests import TuyaDeviceTestCase
|
|
|
-
|
|
|
-POWER_DPS = "101"
|
|
|
-TEMPERATURE_DPS = "102"
|
|
|
-HVACMODE_DPS = "103"
|
|
|
-UNKNOWN104_DPS = "104"
|
|
|
-CURRENTTEMP_DPS = "105"
|
|
|
-FLOORTEMP_DPS = "106"
|
|
|
-UNIT_DPS = "107"
|
|
|
-LOCK_DPS = "108"
|
|
|
-UNKNOWN109_DPS = "109"
|
|
|
-SCHED_DPS = "110"
|
|
|
-SENSOR_DPS = "111"
|
|
|
-UNKNOWN112_DPS = "112"
|
|
|
-UNKNOWN113_DPS = "113"
|
|
|
-CALIB_DPS = "116"
|
|
|
-RUNTIME_DPS = "117"
|
|
|
-HVACACTION_DPS = "118"
|
|
|
-TEMPLIMIT_DPS = "121"
|
|
|
-
|
|
|
-
|
|
|
-class TestJiahongEt72wThermostat(
|
|
|
- BasicLockTests,
|
|
|
- BasicNumberTests,
|
|
|
- MultiSelectTests,
|
|
|
- MultiSensorTests,
|
|
|
- TargetTemperatureTests,
|
|
|
- TuyaDeviceTestCase,
|
|
|
-):
|
|
|
- __test__ = True
|
|
|
-
|
|
|
- def setUp(self):
|
|
|
- self.setUpForConfig(
|
|
|
- "jiahong_et72w_thermostat.yaml",
|
|
|
- JIAHONG_ET72W_PAYLOAD,
|
|
|
- )
|
|
|
- self.subject = self.entities.get("climate")
|
|
|
- self.setUpTargetTemperature(
|
|
|
- TEMPERATURE_DPS,
|
|
|
- self.subject,
|
|
|
- min=5.0,
|
|
|
- max=40.0,
|
|
|
- scale=10,
|
|
|
- step=5,
|
|
|
- )
|
|
|
- self.setUpBasicLock(LOCK_DPS, self.entities.get("lock_screen_lock"))
|
|
|
- self.setUpMultiSelect(
|
|
|
- [
|
|
|
- {
|
|
|
- "dps": SCHED_DPS,
|
|
|
- "name": "select_auto_schedule",
|
|
|
- "options": {
|
|
|
- 0: "7",
|
|
|
- 1: "5+1+1",
|
|
|
- 2: "7 (Adaptive)",
|
|
|
- 3: "5+1+1 (Adaptive)",
|
|
|
- },
|
|
|
- },
|
|
|
- {
|
|
|
- "dps": UNIT_DPS,
|
|
|
- "name": "select_temperature_unit",
|
|
|
- "options": {
|
|
|
- False: "celsius",
|
|
|
- True: "fahrenheit",
|
|
|
- },
|
|
|
- },
|
|
|
- {
|
|
|
- "dps": SENSOR_DPS,
|
|
|
- "name": "select_temperature_sensor",
|
|
|
- "options": {
|
|
|
- "0": "Room",
|
|
|
- "1": "Floor",
|
|
|
- "2": "Both",
|
|
|
- },
|
|
|
- },
|
|
|
- ],
|
|
|
- )
|
|
|
- self.setUpBasicNumber(
|
|
|
- TEMPLIMIT_DPS,
|
|
|
- self.entities.get("number_room_temperature_limit"),
|
|
|
- device_class=NumberDeviceClass.TEMPERATURE,
|
|
|
- min=10.0,
|
|
|
- max=40.0,
|
|
|
- step=0.5,
|
|
|
- scale=10,
|
|
|
- unit=UnitOfTemperature.CELSIUS,
|
|
|
- )
|
|
|
- self.setUpMultiSensors(
|
|
|
- [
|
|
|
- {
|
|
|
- "dps": CURRENTTEMP_DPS,
|
|
|
- "name": "sensor_room_temperature",
|
|
|
- "device_class": SensorDeviceClass.TEMPERATURE,
|
|
|
- "state_class": SensorStateClass.MEASUREMENT,
|
|
|
- "unit": UnitOfTemperature.CELSIUS,
|
|
|
- "testdata": (195, 19.5),
|
|
|
- },
|
|
|
- {
|
|
|
- "dps": FLOORTEMP_DPS,
|
|
|
- "name": "sensor_floor_temperature",
|
|
|
- "device_class": SensorDeviceClass.TEMPERATURE,
|
|
|
- "state_class": SensorStateClass.MEASUREMENT,
|
|
|
- "unit": UnitOfTemperature.CELSIUS,
|
|
|
- "testdata": (214, 21.4),
|
|
|
- },
|
|
|
- {
|
|
|
- "dps": RUNTIME_DPS,
|
|
|
- "name": "sensor_runtime",
|
|
|
- "unit": UnitOfTime.MINUTES,
|
|
|
- "testdata": (1234, 1234),
|
|
|
- },
|
|
|
- ]
|
|
|
- )
|
|
|
- self.mark_secondary(
|
|
|
- [
|
|
|
- "lock_screen_lock",
|
|
|
- "number_room_temperature_limit",
|
|
|
- "select_auto_schedule",
|
|
|
- "select_temperature_sensor",
|
|
|
- "select_temperature_unit",
|
|
|
- ],
|
|
|
- )
|
|
|
-
|
|
|
- def test_supported_features(self):
|
|
|
- self.assertEqual(
|
|
|
- self.subject.supported_features,
|
|
|
- ClimateEntityFeature.TARGET_TEMPERATURE
|
|
|
- | ClimateEntityFeature.TURN_OFF
|
|
|
- | ClimateEntityFeature.TURN_ON,
|
|
|
- )
|
|
|
-
|
|
|
- def test_temperature_unit(self):
|
|
|
- self.dps[UNIT_DPS] = False
|
|
|
- self.assertEqual(
|
|
|
- self.subject.temperature_unit,
|
|
|
- UnitOfTemperature.CELSIUS,
|
|
|
- )
|
|
|
- self.assertEqual(self.subject.target_temperature_step, 0.5)
|
|
|
-
|
|
|
- self.dps[UNIT_DPS] = True
|
|
|
- self.assertEqual(
|
|
|
- self.subject.temperature_unit,
|
|
|
- UnitOfTemperature.FAHRENHEIT,
|
|
|
- )
|
|
|
- self.assertEqual(self.subject.target_temperature_step, 3.0)
|
|
|
-
|
|
|
- def test_current_temperature(self):
|
|
|
- self.dps[CURRENTTEMP_DPS] = 385
|
|
|
- self.assertEqual(self.subject.current_temperature, 38.5)
|
|
|
-
|
|
|
- def test_farenheit(self):
|
|
|
- self.dps[UNIT_DPS] = True
|
|
|
- # these seem suspicious, but are the values provided by the device
|
|
|
- # owner in the config. Basically in C they translate to:
|
|
|
- # Setting C F
|
|
|
- # min temp 5 12F = -11C
|
|
|
- # max temp 40 75F = 24C
|
|
|
- # temp step 0.5 3F = 2C
|
|
|
- # It seems more likely that it should be 40 - 100 with step 1
|
|
|
- # (or in the config, 400 - 1000, step 10, scale 10)
|
|
|
- self.assertEqual(self.subject.min_temp, 12.0)
|
|
|
- self.assertEqual(self.subject.max_temp, 75.0)
|
|
|
- self.assertEqual(self.subject.target_temperature_step, 3.0)
|
|
|
-
|
|
|
- def test_hvac_mode(self):
|
|
|
- self.dps[POWER_DPS] = False
|
|
|
- self.dps[HVACMODE_DPS] = "Smart"
|
|
|
- self.assertEqual(self.subject.hvac_mode, HVACMode.OFF)
|
|
|
-
|
|
|
- self.dps[POWER_DPS] = True
|
|
|
- self.assertEqual(self.subject.hvac_mode, HVACMode.AUTO)
|
|
|
-
|
|
|
- self.dps[HVACMODE_DPS] = "Manual"
|
|
|
- self.assertEqual(self.subject.hvac_mode, HVACMode.HEAT)
|
|
|
-
|
|
|
- self.dps[HVACMODE_DPS] = "Anti_frozen"
|
|
|
- self.assertEqual(self.subject.hvac_mode, HVACMode.COOL)
|
|
|
-
|
|
|
- def test_hvac_modes(self):
|
|
|
- self.assertCountEqual(
|
|
|
- self.subject.hvac_modes,
|
|
|
- [
|
|
|
- HVACMode.AUTO,
|
|
|
- HVACMode.COOL,
|
|
|
- HVACMode.HEAT,
|
|
|
- HVACMode.OFF,
|
|
|
- ],
|
|
|
- )
|
|
|
-
|
|
|
- async def test_set_target_temperature_fails_outside_valid_range(self):
|
|
|
- with self.assertRaisesRegex(
|
|
|
- ValueError,
|
|
|
- "temperature \\(4.5\\) must be between 5.0 and 40.0",
|
|
|
- ):
|
|
|
- await self.subject.async_set_target_temperature(4.5)
|
|
|
- with self.assertRaisesRegex(
|
|
|
- ValueError,
|
|
|
- "temperature \\(41\\) must be between 5.0 and 40.0",
|
|
|
- ):
|
|
|
- await self.subject.async_set_target_temperature(41)
|
|
|
-
|
|
|
- def test_extra_state_attributes(self):
|
|
|
- self.dps[UNKNOWN104_DPS] = 104
|
|
|
- self.dps[UNKNOWN109_DPS] = True
|
|
|
- self.dps[UNKNOWN112_DPS] = 112
|
|
|
- self.dps[UNKNOWN113_DPS] = 113
|
|
|
- self.assertDictEqual(
|
|
|
- self.subject.extra_state_attributes,
|
|
|
- {
|
|
|
- "unknown_104": 104,
|
|
|
- "unknown_109": True,
|
|
|
- "unknown_112": 112,
|
|
|
- "unknown_113": 113,
|
|
|
- },
|
|
|
- )
|
|
|
-
|
|
|
- def test_multi_sensor_extra_state_attributes(self):
|
|
|
- self.dps[CALIB_DPS] = 321
|
|
|
- self.assertEqual(
|
|
|
- self.multiSensor["sensor_runtime"].extra_state_attributes,
|
|
|
- {"calibration": 321},
|
|
|
- )
|
|
|
-
|
|
|
- def test_icons(self):
|
|
|
- self.dps[LOCK_DPS] = True
|
|
|
- self.assertEqual(self.basicLock.icon, "mdi:hand-back-right-off")
|
|
|
- self.dps[LOCK_DPS] = False
|
|
|
- self.assertEqual(self.basicLock.icon, "mdi:hand-back-right")
|