@@ -0,0 +1,377 @@
|
|
|
+name: Energy meter
|
|
|
+products:
|
|
|
+ - id: fzxonzodwjiugioz
|
|
|
+ name: Zemismart SDM01-TW0-12-ZM
|
|
|
+primary_entity:
|
|
|
+ entity: sensor
|
|
|
+ class: energy
|
|
|
+ translation_key: energy_consumed
|
|
|
+ dps:
|
|
|
+ - id: 1
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kWh
|
|
|
+ class: total_increasing
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ # Standard phase dps do not appear in log, and data appears to be covered
|
|
|
+ # as X/Y/Z below, so not decoded
|
|
|
+ - id: 6
|
|
|
+ type: string
|
|
|
+ optional: true
|
|
|
+ name: phase_a
|
|
|
+ - id: 7
|
|
|
+ type: string
|
|
|
+ optional: true
|
|
|
+ name: phase_b
|
|
|
+ - id: 8
|
|
|
+ type: string
|
|
|
+ optional: true
|
|
|
+ name: phase_c
|
|
|
+ # Alarms are binary encoded and do not appear in logs, so not decoded
|
|
|
+ - id: 17
|
|
|
+ type: string
|
|
|
+ optional: true
|
|
|
+ name: alarm_set_1
|
|
|
+ - id: 18
|
|
|
+ type: string
|
|
|
+ optional: true
|
|
|
+ name: alarm_set_2
|
|
|
+ - id: 19
|
|
|
+ type: string
|
|
|
+ name: breaker_id
|
|
|
+ - id: 131
|
|
|
+ type: integer
|
|
|
+ name: r485_address
|
|
|
+ - id: 132
|
|
|
+ type: string
|
|
|
+ name: r485_baud_rate
|
|
|
+ - id: 133
|
|
|
+ type: string
|
|
|
+ name: r485_data_format
|
|
|
+secondary_entities:
|
|
|
+ - entity: binary_sensor
|
|
|
+ class: problem
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: 0
|
|
|
+ value: false
|
|
|
+ - value: true
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: fault_code
|
|
|
+ - entity: button
|
|
|
+ name: Clear energy
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 12
|
|
|
+ type: boolean
|
|
|
+ optional: true
|
|
|
+ name: button
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: energy_produced
|
|
|
+ class: energy
|
|
|
+ dps:
|
|
|
+ - id: 23
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kWh
|
|
|
+ class: total_increasing
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: sensor
|
|
|
+ class: power
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 29
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kW
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ class: frequency
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 32
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: Hz
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: binary_sensor
|
|
|
+ class: connectivity
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 35
|
|
|
+ type: string
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: online
|
|
|
+ value: true
|
|
|
+ - dps_val: offline
|
|
|
+ value: false
|
|
|
+ - entity: sensor
|
|
|
+ class: power_factor
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 50
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: switch
|
|
|
+ name: Locator
|
|
|
+ category: config
|
|
|
+ icon: "mdi:led-on"
|
|
|
+ dps:
|
|
|
+ - id: 101
|
|
|
+ type: boolean
|
|
|
+ name: switch
|
|
|
+ - entity: number
|
|
|
+ name: Reporting interval
|
|
|
+ category: config
|
|
|
+ icon: "mdi:autorenew"
|
|
|
+ dps:
|
|
|
+ - id: 102
|
|
|
+ type: integer
|
|
|
+ name: value
|
|
|
+ unit: s
|
|
|
+ range:
|
|
|
+ min: 5
|
|
|
+ max: 3600
|
|
|
+ - entity: sensor
|
|
|
+ name: Voltage X
|
|
|
+ class: voltage
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 103
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: V
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ name: Current X
|
|
|
+ class: current
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 104
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: A
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ name: Power X
|
|
|
+ class: power
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 105
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kW
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ name: Power factor X
|
|
|
+ class: power_factor
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 108
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ class: measurement
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: energy_consumed_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: X
|
|
|
+ class: energy
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 109
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kWh
|
|
|
+ class: total_increasing
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: energy_produced_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: X
|
|
|
+ class: energy
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 110
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kWh
|
|
|
+ class: total_increasing
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: sensor
|
|
|
+ name: Voltage Y
|
|
|
+ class: voltage
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 112
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: V
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ name: Current Y
|
|
|
+ class: current
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 113
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: A
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ name: Power Y
|
|
|
+ class: power
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 114
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kW
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ name: Power factor Y
|
|
|
+ class: power_factor
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 117
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ class: measurement
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: energy_consumed_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: Y
|
|
|
+ class: energy
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 118
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kWh
|
|
|
+ class: total_increasing
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: energy_produced_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: Y
|
|
|
+ class: energy
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 119
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kWh
|
|
|
+ class: total_increasing
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: sensor
|
|
|
+ name: Voltage Z
|
|
|
+ class: voltage
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 121
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: V
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ name: Current Z
|
|
|
+ class: current
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 122
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: A
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ name: Power Z
|
|
|
+ class: power
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 123
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kW
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ name: Power factor Z
|
|
|
+ class: power_factor
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 126
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ class: measurement
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: energy_consumed_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: Z
|
|
|
+ class: energy
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 127
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kWh
|
|
|
+ class: total_increasing
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: energy_produced_x
|
|
|
+ translation_placeholders:
|
|
|
+ x: Z
|
|
|
+ class: energy
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 128
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kWh
|
|
|
+ class: total_increasing
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: sensor
|
|
|
+ name: Current imbalance
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 130
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: "%"
|
|
|
+ class: measurement
|