@@ -0,0 +1,492 @@
|
|
|
+name: EV charger
|
|
|
+products:
|
|
|
+ - id: tj9l3ghsjnbdjom6
|
|
|
+ manufacturer: Absina
|
|
|
+ model: wallbox 11kw
|
|
|
+entities:
|
|
|
+ # Always charger_free, function unclear
|
|
|
+ # - entity: sensor # work_state -3- enum
|
|
|
+ # name: Charger State
|
|
|
+ # #translation_key: status
|
|
|
+ # icon: "mdi:ev-station"
|
|
|
+ # class: enum
|
|
|
+ # dps:
|
|
|
+ # - id: 3
|
|
|
+ # type: string
|
|
|
+ # name: sensor
|
|
|
+ # mapping:
|
|
|
+ # - dps_val: charger_free
|
|
|
+ # value: available
|
|
|
+ # - dps_val: charger_insert
|
|
|
+ # value: plugged_in
|
|
|
+ # - dps_val: charger_free_fault
|
|
|
+ # value: fault_unplugged
|
|
|
+ # - dps_val: charger_wait
|
|
|
+ # value: waiting
|
|
|
+ # - dps_val: charger_charging
|
|
|
+ # value: charging
|
|
|
+ # - dps_val: charger_pause
|
|
|
+ # value: paused
|
|
|
+ # - dps_val: charger_end
|
|
|
+ # value: charged
|
|
|
+ # - dps_val: charger_fault
|
|
|
+ # value: fault
|
|
|
+ # - id: 11 # alarm_set_1 -11-
|
|
|
+ # optional: true
|
|
|
+ # type: string
|
|
|
+ # name: alarm_set_1
|
|
|
+ # - id: 12 # alarm_set_2 -12-
|
|
|
+ # optional: true
|
|
|
+ # type: string
|
|
|
+ # name: alarm_set_2
|
|
|
+ # - id: 23 # system_version -23-
|
|
|
+ # type: string
|
|
|
+ # optional: true
|
|
|
+ # name: system_version
|
|
|
+
|
|
|
+ - entity: binary_sensor # fault -10- OK
|
|
|
+ class: problem
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 10
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: 0
|
|
|
+ value: false
|
|
|
+ - value: true
|
|
|
+ - id: 10
|
|
|
+ type: bitfield
|
|
|
+ name: fault_code
|
|
|
+ - id: 10
|
|
|
+ type: bitfield
|
|
|
+ name: description
|
|
|
+ mapping:
|
|
|
+ - dps_val: 0
|
|
|
+ value: "Ready"
|
|
|
+ - dps_val: 1
|
|
|
+ value: "err_uvp"
|
|
|
+ - dps_val: 2
|
|
|
+ value: "err_ovp"
|
|
|
+ - dps_val: 4
|
|
|
+ value: "err_ocp"
|
|
|
+ - dps_val: 8
|
|
|
+ value: "err_pe"
|
|
|
+ - dps_val: 16
|
|
|
+ value: "err_temp"
|
|
|
+ - dps_val: 32
|
|
|
+ value: "err_cp"
|
|
|
+ - dps_val: 64
|
|
|
+ value: "err_leak"
|
|
|
+ - dps_val: 128
|
|
|
+ value: "err_leaksc"
|
|
|
+ - dps_val: 256
|
|
|
+ value: "err_pe2"
|
|
|
+ - dps_val: 512
|
|
|
+ value: "err_temp_plug"
|
|
|
+ - dps_val: 1024
|
|
|
+ value: "err_temp_pcb"
|
|
|
+ - dps_val: 2048
|
|
|
+ value: "err_temp_core"
|
|
|
+ - dps_val: 4096
|
|
|
+ value: "err_esb"
|
|
|
+ - dps_val: 8192
|
|
|
+ value: "err_pe_sck"
|
|
|
+
|
|
|
+ # Duplicate to Setting, only filled up after change
|
|
|
+ # - entity: sensor # work_mode -14- OK
|
|
|
+ # name: Chg mode
|
|
|
+ # #translation_key: status
|
|
|
+ # icon: "mdi:ev-station"
|
|
|
+ # class: enum
|
|
|
+ # dps:
|
|
|
+ # - id: 14
|
|
|
+ # type: string
|
|
|
+ # name: sensor
|
|
|
+ # mapping:
|
|
|
+ # - dps_val: charge_now
|
|
|
+ # value: Immediate
|
|
|
+ # - dps_val: charge_pct
|
|
|
+ # value: Charge to percent
|
|
|
+ # - dps_val: charge_energy
|
|
|
+ # value: Fixed charge
|
|
|
+ # - dps_val: charge_schedule
|
|
|
+ # value: Scheduled charge
|
|
|
+
|
|
|
+ - entity: select # work_mode -14- OK
|
|
|
+ name: Charging mode
|
|
|
+ icon: "mdi:ev-station"
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 14
|
|
|
+ type: string
|
|
|
+ name: option
|
|
|
+ mapping:
|
|
|
+ - dps_val: charge_now
|
|
|
+ value: Immediate charge
|
|
|
+ - dps_val: charge_schedule
|
|
|
+ value: Scheduled charge
|
|
|
+ - dps_val: charge_pct
|
|
|
+ value: Charge to percent
|
|
|
+ - dps_val: charge_energy
|
|
|
+ value: Fixed charge
|
|
|
+
|
|
|
+ # Always 0, function unclear
|
|
|
+ # - entity: sensor # balance_energy -15-
|
|
|
+ # name: balance_energy
|
|
|
+ # class: energy
|
|
|
+ # dps:
|
|
|
+ # - id: 15
|
|
|
+ # type: integer
|
|
|
+ # name: sensor
|
|
|
+ # unit: kWh
|
|
|
+ # range:
|
|
|
+ # min: 0
|
|
|
+ # max: 99999999
|
|
|
+ # step: 1
|
|
|
+ # mapping:
|
|
|
+ # - scale: 1000
|
|
|
+
|
|
|
+ # Sets Value on Cloud but unclear what function it has
|
|
|
+ - entity: switch # clear_energy -16- OK
|
|
|
+ name: Clear energy
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 16
|
|
|
+ type: boolean
|
|
|
+ name: switch
|
|
|
+
|
|
|
+ # Seems like Factory Reset
|
|
|
+ - entity: button # switch -18- OK
|
|
|
+ name: Factory reset
|
|
|
+ class: reset
|
|
|
+ category: config
|
|
|
+ hidden: true
|
|
|
+ dps:
|
|
|
+ - id: 18
|
|
|
+ type: boolean
|
|
|
+ name: button
|
|
|
+
|
|
|
+ # Always 1, unclear functiuon
|
|
|
+ # - entity: sensor # charge_energy_once -25-
|
|
|
+ # name: charge_energy_once
|
|
|
+ # class: energy
|
|
|
+ # category: config
|
|
|
+ # dps:
|
|
|
+ # - id: 25
|
|
|
+ # type: integer
|
|
|
+ # name: value
|
|
|
+ # unit: kWh
|
|
|
+ # range:
|
|
|
+ # min: 1
|
|
|
+ # max: 999999
|
|
|
+ # step: 1
|
|
|
+ # mapping:
|
|
|
+ # - scale: 100
|
|
|
+
|
|
|
+ - entity: binary_sensor # online_state -27-
|
|
|
+ #Name: Connected
|
|
|
+ class: connectivity
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 27
|
|
|
+ type: string
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: online
|
|
|
+ value: true
|
|
|
+ - dps_val: offline
|
|
|
+ value: false
|
|
|
+
|
|
|
+ - entity: sensor # DeviceState -101- OK
|
|
|
+ name: Device State
|
|
|
+ icon: "mdi:ev-station"
|
|
|
+ class: enum
|
|
|
+ dps:
|
|
|
+ - id: 101
|
|
|
+ type: string
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: no_connet
|
|
|
+ value: "Not Connected"
|
|
|
+ - dps_val: connect
|
|
|
+ value: "Connected"
|
|
|
+ - dps_val: charing
|
|
|
+ value: "Charging"
|
|
|
+ - dps_val: wait_rfid
|
|
|
+ value: "Wait fro RFID Auth"
|
|
|
+ - dps_val: finish
|
|
|
+ value: "Finished"
|
|
|
+ - dps_val: wait_charing
|
|
|
+ value: "Wait for Charging"
|
|
|
+ - dps_val: error
|
|
|
+ value: "Error"
|
|
|
+
|
|
|
+ # Only Channel A is providing values
|
|
|
+ - entity: sensor # A_Voltage -102-104- OK
|
|
|
+ name: Phase A voltage
|
|
|
+ class: voltage
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 102
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: V
|
|
|
+ class: measurement
|
|
|
+ - entity: sensor # B_Voltage
|
|
|
+ hidden: true
|
|
|
+ name: Phase B voltage
|
|
|
+ class: voltage
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 103
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: V
|
|
|
+ class: measurement
|
|
|
+ - entity: sensor # C_Voltage
|
|
|
+ name: Phase C voltage
|
|
|
+ hidden: true
|
|
|
+ class: voltage
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 104
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: V
|
|
|
+ class: measurement
|
|
|
+
|
|
|
+ # Only Channel A is providing values
|
|
|
+ - entity: sensor # A_Current -105-107- OK
|
|
|
+ name: Phase A current
|
|
|
+ class: current
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 105
|
|
|
+ name: sensor
|
|
|
+ type: integer
|
|
|
+ unit: A
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor # B_Current
|
|
|
+ name: Phase B current
|
|
|
+ hidden: true
|
|
|
+ class: current
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 106
|
|
|
+ name: sensor
|
|
|
+ type: integer
|
|
|
+ unit: A
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor # C_Current
|
|
|
+ name: Phase C current
|
|
|
+ hidden: true
|
|
|
+ class: current
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 107
|
|
|
+ name: sensor
|
|
|
+ type: integer
|
|
|
+ unit: A
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+
|
|
|
+ # Seems not to work or change. on single phase even when loading 3 phase
|
|
|
+ # - entity: sensor # PhaseFlag -108-
|
|
|
+ # name: Phase
|
|
|
+ # icon: "mdi:transmission-tower"
|
|
|
+ # class: enum
|
|
|
+ # dps:
|
|
|
+ # - id: 108
|
|
|
+ # type: string
|
|
|
+ # name: sensor
|
|
|
+ # mapping:
|
|
|
+ # - dps_val: Single_phase
|
|
|
+ # value: "1-Phase"
|
|
|
+ # - dps_val: Three_phase
|
|
|
+ # value: "3-Phase"
|
|
|
+ # - dps_val: No_phase
|
|
|
+ # value: "No Phase"
|
|
|
+ # - dps_val: Phase_err
|
|
|
+ # value: "Phase Error"
|
|
|
+
|
|
|
+ - entity: sensor # DeviceKw -109- OK
|
|
|
+ name: Charging Power
|
|
|
+ class: power
|
|
|
+ dps:
|
|
|
+ - id: 109
|
|
|
+ optional: true
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kW
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+
|
|
|
+ - entity: sensor #DeviceTemp -110- OK
|
|
|
+ name: Device Temperature
|
|
|
+ class: temperature
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 110
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: C
|
|
|
+ range:
|
|
|
+ min: -300
|
|
|
+ max: 1050
|
|
|
+ step: 1
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+
|
|
|
+ - entity: sensor # DeviceKwh -112- OK
|
|
|
+ name: Energy
|
|
|
+ class: energy
|
|
|
+ dps:
|
|
|
+ - id: 112
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kWh
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+
|
|
|
+ - entity: sensor # DeviceMaxSetA -113- OK
|
|
|
+ name: DeviceMaxSetA
|
|
|
+ class: enum
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 113
|
|
|
+ type: string
|
|
|
+ name: sensor
|
|
|
+
|
|
|
+ - entity: number # Set16A -114- OK
|
|
|
+ name: Charging current limit
|
|
|
+ class: current
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 114
|
|
|
+ type: integer
|
|
|
+ name: value
|
|
|
+ unit: A
|
|
|
+ range:
|
|
|
+ min: 8
|
|
|
+ max: 16
|
|
|
+ step: 1
|
|
|
+
|
|
|
+ # Current regulation for devices with higher power than 11kw, untested
|
|
|
+ - entity: number # Set32A -115- OK
|
|
|
+ name: Charging current limit 32A
|
|
|
+ hidden: true
|
|
|
+ class: current
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 115
|
|
|
+ type: integer
|
|
|
+ name: value
|
|
|
+ unit: A
|
|
|
+ range:
|
|
|
+ min: 8
|
|
|
+ max: 32
|
|
|
+ step: 1
|
|
|
+ - entity: number # Set40A -116- OK
|
|
|
+ name: Charging current limit 40A
|
|
|
+ hidden: true
|
|
|
+ class: current
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 116
|
|
|
+ type: integer
|
|
|
+ name: value
|
|
|
+ unit: A
|
|
|
+ range:
|
|
|
+ min: 12
|
|
|
+ max: 40
|
|
|
+ step: 1
|
|
|
+ - entity: number # Set50A -117- OK
|
|
|
+ name: Charging current limit 50A
|
|
|
+ hidden: true
|
|
|
+ class: current
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 117
|
|
|
+ type: integer
|
|
|
+ name: value
|
|
|
+ unit: A
|
|
|
+ range:
|
|
|
+ min: 12
|
|
|
+ max: 50
|
|
|
+ step: 1
|
|
|
+
|
|
|
+ - entity: number # SetDelayTime -118- OK
|
|
|
+ name: Charging Delay
|
|
|
+ class: time
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 118
|
|
|
+ type: integer
|
|
|
+ name: value
|
|
|
+ unit: h
|
|
|
+ range:
|
|
|
+ min: 0
|
|
|
+ max: 15
|
|
|
+ step: 1
|
|
|
+
|
|
|
+ - entity: number # SetDefineTime -119- OK
|
|
|
+ name: Charging Time
|
|
|
+ class: time
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 119
|
|
|
+ type: integer
|
|
|
+ name: value
|
|
|
+ unit: h
|
|
|
+ range:
|
|
|
+ min: 0
|
|
|
+ max: 15
|
|
|
+ step: 1
|
|
|
+
|
|
|
+ - entity: sensor #CTime2 -121- OK
|
|
|
+ name: Chg Session Time
|
|
|
+ class: time
|
|
|
+ dps:
|
|
|
+ - id: 121
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: h
|
|
|
+ range:
|
|
|
+ min: 0
|
|
|
+ max: 480
|
|
|
+ step: 1
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+
|
|
|
+ - entity: switch # IDVerificationSet -122-
|
|
|
+ name: IDVerification
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 122
|
|
|
+ type: boolean
|
|
|
+ name: switch
|
|
|
+
|
|
|
+ - entity: switch # RFID -123-
|
|
|
+ name: RFID
|
|
|
+ class: identify
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 123
|
|
|
+ type: boolean
|
|
|
+ name: switch
|
|
|
+
|
|
|
+ # Seems not to work with the charger as always on waitOperation
|
|
|
+ # - entity: sensor # ChargingOperation -124-
|
|
|
+ # name: ChargingOperation
|
|
|
+ # class: enum
|
|
|
+ # dps:
|
|
|
+ # - id: 124
|
|
|
+ # type: string
|
|
|
+ # name: sensor
|