@@ -0,0 +1,209 @@
|
|
|
+name: Thermostat
|
|
|
+products:
|
|
|
+ - id: fy012zc3l51doakx
|
|
|
+ manufacturer: ELKO
|
|
|
+ model: EKO07262
|
|
|
+entities:
|
|
|
+ - entity: climate
|
|
|
+ translation_key: thermostat
|
|
|
+ dps:
|
|
|
+ - id: 116
|
|
|
+ name: hvac_mode
|
|
|
+ type: boolean
|
|
|
+ mapping:
|
|
|
+ - dps_val: true
|
|
|
+ value: "off"
|
|
|
+ - dps_val: false
|
|
|
+ value: heat
|
|
|
+ - id: 152
|
|
|
+ name: hvac_action
|
|
|
+ type: boolean
|
|
|
+ mapping:
|
|
|
+ - dps_val: true
|
|
|
+ value: heating
|
|
|
+ - dps_val: false
|
|
|
+ value: idle
|
|
|
+ - id: 107
|
|
|
+ name: temperature
|
|
|
+ type: integer
|
|
|
+ unit: C
|
|
|
+ range:
|
|
|
+ min: 0
|
|
|
+ max: 4000
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ step: 10
|
|
|
+ - id: 104
|
|
|
+ name: current_temperature
|
|
|
+ type: integer
|
|
|
+ unit: C
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ constraint: device_preset
|
|
|
+ conditions:
|
|
|
+ - dps_val: [7, 8]
|
|
|
+ value_redirect: floor_temperature
|
|
|
+ - id: 118
|
|
|
+ name: device_preset
|
|
|
+ type: integer
|
|
|
+ - id: 105
|
|
|
+ type: integer
|
|
|
+ name: floor_temperature
|
|
|
+ unit: C
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - id: 140
|
|
|
+ name: preset_mode
|
|
|
+ type: string
|
|
|
+ mapping:
|
|
|
+ - dps_val: Manual
|
|
|
+ value: manual
|
|
|
+ - dps_val: Schedule
|
|
|
+ value: program
|
|
|
+ - dps_val: Override
|
|
|
+ value: boost
|
|
|
+ - dps_val: "Off"
|
|
|
+ value: none
|
|
|
+ - entity: number
|
|
|
+ name: Power rating
|
|
|
+ category: config
|
|
|
+ class: power
|
|
|
+ dps:
|
|
|
+ - id: 103
|
|
|
+ name: value
|
|
|
+ type: integer
|
|
|
+ unit: W
|
|
|
+ range:
|
|
|
+ min: 0
|
|
|
+ max: 3600
|
|
|
+ - entity: lock
|
|
|
+ translation_key: child_lock
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 131
|
|
|
+ name: lock
|
|
|
+ type: boolean
|
|
|
+ - entity: number
|
|
|
+ name: Active screen brightness
|
|
|
+ icon: "mdi:brightness-6"
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 132
|
|
|
+ name: value
|
|
|
+ type: integer
|
|
|
+ unit: "%"
|
|
|
+ range:
|
|
|
+ min: 10
|
|
|
+ max: 100
|
|
|
+ - entity: number
|
|
|
+ name: Standby screen brightness
|
|
|
+ icon: "mdi:brightness-4"
|
|
|
+ category: config
|
|
|
+ dps:
|
|
|
+ - id: 133
|
|
|
+ name: value
|
|
|
+ type: integer
|
|
|
+ unit: "%"
|
|
|
+ range:
|
|
|
+ min: 0
|
|
|
+ max: 100
|
|
|
+ - entity: sensor
|
|
|
+ name: Sensor type
|
|
|
+ icon: "mdi:thermometer-probe"
|
|
|
+ category: diagnostic
|
|
|
+ class: enum
|
|
|
+ dps:
|
|
|
+ - id: 129
|
|
|
+ type: string
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: "Not_Fitted"
|
|
|
+ value: "Not Fitted"
|
|
|
+ - dps_val: "2K"
|
|
|
+ value: "2K Ohm"
|
|
|
+ - dps_val: "10K"
|
|
|
+ value: "10K Ohm"
|
|
|
+ - dps_val: "12K"
|
|
|
+ value: "12K Ohm"
|
|
|
+ - dps_val: "15K"
|
|
|
+ value: "15K Ohm"
|
|
|
+ - dps_val: "33K"
|
|
|
+ value: "33K Ohm"
|
|
|
+ - dps_val: "47K"
|
|
|
+ value: "47K Ohm"
|
|
|
+ - entity: sensor
|
|
|
+ name: Device type
|
|
|
+ icon: "mdi:cog"
|
|
|
+ category: diagnostic
|
|
|
+ class: enum
|
|
|
+ dps:
|
|
|
+ - id: 118
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: 1
|
|
|
+ value: "Heat Pump/Oil Boiler"
|
|
|
+ - dps_val: 2
|
|
|
+ value: "Hydronic Radiator/Gas Boiler"
|
|
|
+ - dps_val: 3
|
|
|
+ value: "Hydronic Underfloor"
|
|
|
+ - dps_val: 4
|
|
|
+ value: "Electrical Radiator"
|
|
|
+ - dps_val: 5
|
|
|
+ value: "Electrical Underfloor (Without floor limits)"
|
|
|
+ - dps_val: 6
|
|
|
+ value: "Electrical Underfloor (With floor limits)"
|
|
|
+ - dps_val: 7
|
|
|
+ value: "Hydronic Underfloor"
|
|
|
+ - dps_val: 8
|
|
|
+ value: "Electrical Underfloor"
|
|
|
+ - dps_val: 9
|
|
|
+ value: "Regulator Mode (output displayed is based on percentage)"
|
|
|
+ - entity: sensor
|
|
|
+ name: Floor temperature
|
|
|
+ category: diagnostic
|
|
|
+ hidden: unavailable
|
|
|
+ dps:
|
|
|
+ - id: 105
|
|
|
+ name: sensor
|
|
|
+ type: integer
|
|
|
+ unit: C
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - id: 129
|
|
|
+ name: available
|
|
|
+ type: string
|
|
|
+ mapping:
|
|
|
+ - dps_val: "Not_Fitted"
|
|
|
+ value: false
|
|
|
+ - value: true
|
|
|
+ - entity: sensor
|
|
|
+ name: Air temperature
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 104
|
|
|
+ name: sensor
|
|
|
+ type: integer
|
|
|
+ unit: C
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: sensor
|
|
|
+ class: power
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 150
|
|
|
+ name: sensor
|
|
|
+ type: integer
|
|
|
+ unit: W
|
|
|
+ class: measurement
|
|
|
+ - entity: sensor
|
|
|
+ class: energy
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 151
|
|
|
+ name: sensor
|
|
|
+ type: integer
|
|
|
+ unit: Wh
|
|
|
+ class: total_increasing
|