@@ -0,0 +1,144 @@
|
|
|
+name: Energy meter
|
|
|
+# products:
|
|
|
+# - id: TBC - no Tuya cloud product_id available (no cloud link)
|
|
|
+# manufacturer: Zemismart
|
|
|
+# model: SPM01-D2TW-ZM
|
|
|
+# model_id: Metering_1PN_WiFi
|
|
|
+# Note: this firmware batch of the SPM01-D2TW-ZM uses a different dp layout to
|
|
|
+# the one merged into earu_smart_wifi_circuit_breaker_with_energy_monitor.yaml
|
|
|
+# (upstream issue #2219), which expects dp101/dp16/dp6 that this unit never
|
|
|
+# sends. Confirmed live via direct DPS query: dps 1, 9, 19, 23, 32, 50, 102,
|
|
|
+# 103, 104. See also upstream issue #4081, which reports the same dp23
|
|
|
+# reverse-energy shift on the sibling 3-phase SPM02-D2TW.
|
|
|
+entities:
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: energy_consumed
|
|
|
+ class: energy
|
|
|
+ dps:
|
|
|
+ - id: 1
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kWh
|
|
|
+ class: total_increasing
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - id: 19
|
|
|
+ type: string
|
|
|
+ name: meter_id
|
|
|
+ optional: true
|
|
|
+ - entity: sensor
|
|
|
+ translation_key: energy_produced
|
|
|
+ class: energy
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 23
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: kWh
|
|
|
+ class: total_increasing
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: sensor
|
|
|
+ class: power
|
|
|
+ dps:
|
|
|
+ - id: 104
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: W
|
|
|
+ class: measurement
|
|
|
+ - entity: sensor
|
|
|
+ class: voltage
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 102
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: V
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 10
|
|
|
+ - entity: sensor
|
|
|
+ class: current
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 103
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: A
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 1000
|
|
|
+ - entity: sensor
|
|
|
+ class: frequency
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 32
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: Hz
|
|
|
+ class: measurement
|
|
|
+ mapping:
|
|
|
+ - scale: 100
|
|
|
+ - entity: sensor
|
|
|
+ class: power_factor
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 50
|
|
|
+ type: integer
|
|
|
+ name: sensor
|
|
|
+ unit: "%"
|
|
|
+ class: measurement
|
|
|
+ - entity: binary_sensor
|
|
|
+ class: problem
|
|
|
+ category: diagnostic
|
|
|
+ dps:
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: sensor
|
|
|
+ mapping:
|
|
|
+ - dps_val: 0
|
|
|
+ value: false
|
|
|
+ - value: true
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: fault_code
|
|
|
+ - id: 9
|
|
|
+ type: bitfield
|
|
|
+ name: description
|
|
|
+ mapping:
|
|
|
+ - dps_val: 0
|
|
|
+ value: ok
|
|
|
+ - dps_val: 1
|
|
|
+ value: short_circuit
|
|
|
+ - dps_val: 2
|
|
|
+ value: surge
|
|
|
+ - dps_val: 4
|
|
|
+ value: overload
|
|
|
+ - dps_val: 8
|
|
|
+ value: earth_leak
|
|
|
+ - dps_val: 16
|
|
|
+ value: temperature_difference
|
|
|
+ - dps_val: 32
|
|
|
+ value: fire
|
|
|
+ - dps_val: 64
|
|
|
+ value: high_power
|
|
|
+ - dps_val: 128
|
|
|
+ value: self_test
|
|
|
+ - dps_val: 256
|
|
|
+ value: over_current
|
|
|
+ - dps_val: 512
|
|
|
+ value: unbalanced
|
|
|
+ - dps_val: 1024
|
|
|
+ value: over_voltage
|
|
|
+ - dps_val: 2048
|
|
|
+ value: under_voltage
|
|
|
+ - dps_val: 4096
|
|
|
+ value: miss_phase
|
|
|
+ - dps_val: 8192
|
|
|
+ value: outage
|
|
|
+ - dps_val: 16384
|
|
|
+ value: magnetism
|
|
|
+ - dps_val: 32768
|
|
|
+ value: credit_low
|
|
|
+ - dps_val: 65536
|
|
|
+ value: credit_expired
|