Ver código fonte

Kiturami thermostat: Bath and Summer are reversed.

The word "summer" appeared in the manual description for the "Quick start"
(preheat) option, which was the only thing to go on for assigning which
was which. But that turns out to be wrong.

Issue #2349
Jason Rumney 1 ano atrás
pai
commit
182ceeb8c0

+ 7 - 7
custom_components/tuya_local/devices/kiturami_nctr100_thermostat.yaml

@@ -19,9 +19,9 @@ primary_entity:
           value: heat
         - dps_val: Bath
           value: "off"
+          hidden: true
         - dps_val: Summer
           value: "off"
-          hidden: true
         - dps_val: OutGoing
           value: "off"
           hidden: true
@@ -66,16 +66,16 @@ secondary_entities:
             conditions:
               - dps_val: Interior
                 value: Room
+              - dps_val: OnDol
+                value: Underfloor
               - dps_val: Reservation
                 value: Scheduled
-              - dps_val: OutGoing
-                value: away
-              - dps_val: Bath
-                value: Hot water
               - dps_val: Summer
+                value: Hot water
+              - dps_val: Bath
                 value: Quick start
-              - dps_val: OnDol
-                value: Underfloor
+              - dps_val: OutGoing
+                value: away
       - id: 2
         type: string
         name: mode