Check voltage when outputting voltage.

Previously we assumed that voltage and current are connected, and if one was available, the other would be too.
But it seems that is not the case, and we can get a current reading while the voltage is not reported.
Jason Rumney 5 سال پیش
والد
کامیت
11302be940
1فایلهای تغییر یافته به همراه2 افزوده شده و 4 حذف شده
  1. 2 4
      custom_components/tuya_local/kogan_socket/switch.py

+ 2 - 4
custom_components/tuya_local/kogan_socket/switch.py

@@ -72,9 +72,7 @@ class KoganSocketSwitch(SwitchEntity):
         if pwr is None:
             return STATE_UNAVAILABLE
         else:
-            return (
-                self._device.get_property(PROPERTY_TO_DPS_ID[ATTR_CURRENT_POWER_W]) / 10.0
-            )
+            return (pwr / 10.0)
 
     @property
     def device_state_attributes(self):
@@ -85,7 +83,7 @@ class KoganSocketSwitch(SwitchEntity):
         return {
             ATTR_CURRENT_POWER_W: self.current_power_w,
             ATTR_CURRENT_A: None if current is None else current / 1000.0,
-            ATTR_VOLTAGE_V: None if current is None else voltage / 10.0,
+            ATTR_VOLTAGE_V: None if voltage is None else voltage / 10.0,
             ATTR_TIMER: timer,
         }